- Abstract
1
- 10.1016/j.jval.2011.08.108
PMD36 Cost-Effectiveness of the Ex-Press Glaucoma Filtration Device in the Netherlands
- Oct 27, 2011
- Value in Health
- L De Jong + 4 more +4
Publications from 2021 to 2026
Showing 9 of 9 papers
PMD36 Cost-Effectiveness of the Ex-Press Glaucoma Filtration Device in the Netherlands
PMD1 Nd-Yag Laser Incidence Rate Comparison of Three Monofocal Intraocular Lenses (IOL) 36 Months after Cataract Surgery in France
Economic analysis of cataract surgery in Europe: An analysis of hospital databases available in 11 countries
Comparison of outcomes with multifocal intraocular lenses: a meta-analysis
PurposeTo compare the clinical outcome of different multifocal intraocular lenses (IOLs) based on information reported in the international literature.MethodsAll comparative clinical trials that involved implanting at least one multifocal IOL in patients with cataract or presbyopia were extracted from the literature. Clinical outcomes included uncorrected near visual acuity, uncorrected distance visual acuity, visual acuity, spectacle independence, and halos. Random effects meta-analyses were conducted to compare outcomes for the different IOL types.ResultsTwenty papers were identified describing 11 monofocal IOLs and 35 multifocal IOLs (19 diffractive, including 12 ReSTOR®, 14 refractive, and two accommodative) patient cohorts. Multifocal and monofocal uncorrected distance visual acuity was 0.165 (0.090–0.240) and 0.093 (0.088–0.098), respectively. Compared with monofocal IOLs, multifocal IOLs produced better uncorrected near visual acuity (0.470 [0.322–0.618] versus 0.141 [0.131–0.152]; P < 0.0001), resulting in higher spectacle independence (incidence rate ratio [IRR] 3.62 [2.90–4.52]; P < 0.0001). Compared with refractive multifocal IOLs, diffractive multifocal IOLs produced a similar uncorrected distance visual acuity (0.105 [0.098–0.111] versus 0.085 [0.029–0.140]; P ≤ 0.78, not significant) and better uncorrected near visual acuity (0.217 [0.118–0.317] versus 0.082 [0.067–0.098]; P < 0.0001) resulting in higher spectacle independence (IRR 1.75 [1.24–2.48]; P < 0.001). Compared with other multifocal IOLs, ReSTOR produced a better uncorrected distance visual acuity (0.067 [0.059–0.076] versus 0.093 [0.088–0.098]; P < 0.0001) and better uncorrected near visual acuity (0.064 [0.046–0.082] versus 0.141 [0.131–0.152]; P < 0.006), resulting in higher spectacle independence (IRR 2.06 [1.26–1.36]; P < 0.004). Halo incidence rates with different types of multifocal implants did not differ significantly.ConclusionMultifocal IOLs provide better uncorrected near visual acuity than monofocal IOLs, leading to less need for spectacles. Multifocal IOL design might play a role in postsurgical outcome, because better results were obtained with diffractive lenses. ReSTOR showed better uncorrected near visual acuity, uncorrected distance visual acuity, and higher spectacle independence rates compared with other multifocal IOLs.
Read moreFive-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma.
Background:This study compared the efficacy of the EX-PRESS® glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery.Methods:Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS glaucoma filtration device or underwent a trabeculectomy were followed for up to an additional four years (five total) beyond the original study (39 eyes per treatment group). Risk-benefit data were obtained for up to five years after glaucoma surgery. Outcome variables were intraocular pressures and intraocular pressure medications. Complete success was denoted by intraocular pressure values ≤ 18 mmHg without medication.Results:The EX-PRESS glaucoma filtration device controlled intraocular pressure more effectively without medication for more patients from year 1 (86.8% versus 61.5%, P = 0.01) to year 3 (66.7% versus 41.0%, P = 0.02) than trabeculectomy. At year 1, only 12.8% of patients required intraocular pressure medication after EX-PRESS implantation, compared with 35.9% after trabeculectomy. The proportions became closer at year 5 (41% versus 53.9%). The responder rate was higher with EX-PRESS and time to failure was longer. In addition, surgical interventions for complications were fewer after EX-PRESS implantation.Conclusion:This five-year analysis confirmed and extended the results reported after one year. Compared with trabeculectomy, EX-PRESS provided better intraocular pressure control in the first three years, and patients required fewer intraocular pressure medications and fewer surgical interventions during the five-year study period. For patients with primary open-angle glaucoma, the EX-PRESS glaucoma filtration device, implanted under a superficial scleral flap, produced significantly higher success rates than trabeculectomy. EX-PRESS is an effective device for long-term treatment of primary open-angle glaucoma.
Read moreIn Situ Microtomographically Monitored and Electrochemically Controlled Corrosion Initiation and Propagation in AlMgSi Alloy AA6016
Corrosion susceptibility and the type of corrosion in AlMgSi alloys depend strongly on microstructure. However, it is still unclear what microstructural features trigger corrosion initiation. The direct correlation of second-phase particles with the corrosion propagation path has also never been thoroughly explored. In this work, the role of second-phase particles in corrosion initiation and propagation were studied in alloy AA6016 by using a microelectrochemically controlled microtomography technique. Three topics are discussed in detail, the role of Fe-containing intermetallics, the effect of MgSi particles, and an evidenced type of directed corrosion (exfoliation-like attack): (i) Intergranular corrosion initiates preferentially in Fe-containing intermetallics located at grain boundaries. However, its propagation path is not promoted by these intermetallics. (ii) MgSi particles do not act as transition sites to in-depth corrosion propagation, even if they dissolve. (iii) A type of corrosion called exfoliation-like attack is observed. It is characterized by straight attack into the bulk material. The propagation is found to be independent of grain boundaries and second-phase particles.
Read moreIn situ monitoring of corrosion processes within the bulk of AlMgSi alloys using X-ray microtomography
Comparison of different models for the testing of pilocarpine eyedrops using conventional eyedrops and a novel depot formulation (nanoparticles).
An objective in the development of ophthalmic formulations is the use of in vitro or animal models that closely resemble the clinical situation. For this reason, experiments with conventional pilocarpine nitrate eyedrops and a depot formulation of pilocarpine nitrate sorbed to poly (butylcyanoacrylate) nanoparticles were carried out. In vitro, the diffusion of pilocarpine through bovine cornea was measured using Edelhauser cells. In vivo, the rabbit aqueous humor concentration of pilocarpine and miosis were determined after application of the above formulations. In addition, intraocular pressure was measured. Since pilocarpine has little influence on intraocular pressure in healthy rabbits, the pressure had to be increased artificially. Three models were employed that are described in the literature, namely, the betamethasone model, the alpha-chymotrypsin model, and the water-loading model. Pilocarpine could be loaded onto nanoparticles by 15% but was rapidly released from the nanoparticles based on the bovine corneal experiment. Nanoparticles only enhanced the aqueous humor concentration at 30 min; this increase, however, led to a considerably extended period of miosis as well as a reduction in intraocular pressure. The duration of the action and the intensity of the response were different among the three models tested. According to the present results, the betamethasone model seems to represent the best correlation to the clinical situation.
Read moreEffects of topically applied falintolol: a new beta-adrenergic antagonist for treatment of glaucoma.
Changes in intraocular pressure (IOP) following topical administration of falintolol (0.5%-0.25%), a new beta-blocking agent, were studied in conscious albino rabbits with alpha-chymotrypsin-induced ocular hypertension. The drug produced a reduction in IOP equal to that of timolol. A longer duration of activity was noted with falintolol. The rate of transport of topically applied falintolol through the isolated bovine cornea under conditions simulating normal physiology was linear up to three hours and twice as fast as timolol from 3 to 6 hours. Since topical ocular application of beta-adrenergic antagonists useful in glaucoma therapy can also cause a number of troublesome systemic side effects, several conclusive preclinical investigations were carried out with falintolol. Of major concern was the effect falintolol might have on the pupil, cornea, and heart rate when administered topically. The results show that falintolol does not produce any noteworthy side effects and is capable of being an effective beta-blocking agent in open-angle glaucoma therapy.
Read more