- Research Article
- 10.1016/j.msom.2025.12.009
Détection automatique des micro-éveils : vers une évaluation fiable de la fragmentation du sommeil
- Mar 01, 2026
- Médecine du Sommeil
- Mélissa Barrau + 5 more +5
Publications from 2021 to 2026
Showing 7 of 7 papers
Détection automatique des micro-éveils : vers une évaluation fiable de la fragmentation du sommeil
Comparison of apnea-hypopnea indices determined by using the combinations tracheal sound/nasal pressure sensors and thermistor/nasal pressure sensors
Objective: To show whether the combination of tracheal sounds and nasal pressure sensors (TS/NP). allows the same detection of apneas and hypopneas as the combination of oronasal thermistor and nasal pressure sensors (Therm/NP), the recommended AASM method. Materials and methods: Polysomnographic recordings of 34 patients (6 females, mean age 52.9 ± 10.3 years, and mean BMI 30.0 ± 5.2kg/m2) were analyzed to compare the detection of apneas by 2 different methods of combined airflow signals: a) Therm/NP and b) TS/NP. The two scoring methods were performed randomly and independently form each other. Results of respiratory event detection and AHI using Therm/NP signals as a reference were compared to those obtained by TS/NP signals. Results: The number of respiratory events scored using Therm/NP was 7268 while it was 7329 with TS/NP. The average AHI for all patients were 29.8 ± 22.9 for Therm/NP and 30.0 ± 22.6 /hour for TS/NP. However, 55.3 % of total events scored by Therm/NP were hypopneas while 59.3 % of events scored by TS/NP were apneas. Conclusions: These results show that the association TS/NP reliably detects the same number of respiratory events as Therm/NP despite the difference of apnea to hypopnea ratio between the two methods. The use of TS does not modify AHI calculations and it guarantees accurate sleep apnea diagnosis. Thus, TS can be used as a substitute for oronasal thermistors in sleep recording systems.
Read moreImpact des évènements respiratoires sur l’oxygénation cérébrale chez l’enfant porteur de troubles respiratoires du sommeil
Comparison of Apnea Detection Using Oronasal Thermal Airflow Sensor, Nasal Pressure Transducer, Respiratory Inductance Plethysmography and Tracheal Sound Sensor.
Evaluation of apnea detection using a tracheal sound (TS) sensor during sleep in patients with obstructive sleep apnea. Polysomnographic recordings of 32 patients (25 male, mean age 66.7 ± 15.3 years, and mean body mass index 30.1 ± 4.5 kg/m2) were analyzed to compare the detection of apneas by four different methods of airflow signals: oronasal thermal airflow sensor (thermistor), nasal pressure transducer (NP), respiratory inductance plethysmography (RIPsum) and TS. The four used signals were scored randomly and independently from each other according to American Academy of Sleep Medicine rules. Results of apnea detection using NP, RIPsum and TS signals were compared to those obtained by thermistor as a reference signal. The number of apneas detected by the thermistor was 4,167. The number of apneas detected using the NP was 5,416 (+29.97%), using the RIPsum was 2,959 (-29.71%) and using the TS was 5,019 (+20.45%). The kappa statistics (95% confidence interval) were 0.72 (0.71 to 0.74) for TS, 0.69 (0.67 to 0.70) for NP, and 0.57 (0.55 to 0.59) for RIPsum. The sensitivity/specificity (%) with respect to the thermistor were 99.23/69.27, 64.07/93.06 and 96.06/76.07 for the NP, RIPsum and TS respectively. With the sensor placed properly on the suprasternal notch, tracheal sounds could help detecting apneas that are underscored by the RIPsum and identify apneas that may be overscored by the NP sensor due to mouth breathing. In the absence of thermistor, TS sensors can be used for apnea detection. Registry: German Clinical Trials Register (DRKS), Title: Using the tracheal sound probe of the polygraph CID102 to detect and differentiate obstructive, central, and mixed sleep apneas in patients with sleep disordered breathing, Identifier: DRKS00012795, URL: https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00012795.
Read moreAutomatic identification of sleep and wakefulness using single-channel EEG and respiratory polygraphy signals for the diagnosis of obstructive sleep apnea.
Polysomnography (PSG) is necessary for the accurate estimation of total sleep time (TST) and the calculation of the apnea-hypopnea index (AHI). In type III home sleep apnea testing (HSAT), TST is overestimated because of the lack of electrophysiological sleep recordings. The aim of this study was to evaluate the accuracy and reliability of a novel automated sleep/wake scoring algorithm combining a single electroencephalogram (EEG) channel with actimetry and HSAT signals. The study included 160 patients investigated by PSG for suspected obstructive sleep apnea (OSA). Each PSG was recorded and scored manually using American Academy of Sleep Medicine (AASM) rules. The automatic sleep/wake-scoring algorithm was based on a single-channel EEG (FP2-A1) and the variability analysis of HSAT signals (airflow, snoring, actimetry, light and respiratory inductive plethysmography). Optimal detection thresholds were derived for each signal using a training set. Automatic and manual scorings were then compared epoch by epoch considering two states (sleep and wake). Cohen's kappa coefficient between the manual scoring and the proposed automatic algorithm was substantial, 0.74±0.18, in separating wakefulness and sleep. The sensitivity, specificity and the positive and negative predictive values for the detection of wakefulness were 76.51%±21.67%, 95.48%±5.27%, 81.84%±15.42% and 93.85%±6.23% respectively. Compared with HSAT signals alone, AHI increased by 22.12% and 27 patients changed categories of OSA severity with the automatic sleep/wake-scoring algorithm. Automatic sleep/wake detection using a single-channel EEG combined with HSAT signals was a reliable method for TST estimation and improved AHI calculation compared with HSAT.
Read moreCharacterization of Respiratory Events in Obstructive Sleep Apnea Using Suprasternal Pressure Monitoring.
In obstructive sleep apnea (OSA) esophageal pressure (Pes) is the gold standard for measurement of respiratory effort, and respiratory inductance plethysmography (RIP) is considered an accepted measurement technique. However, the use of RIP could lead to limited accuracy in certain cases and therefore suprasternal pressure (SSP) monitoring might improve the reliability of OSA diagnosis. We aimed to use SSP for the visual characterization of respiratory events in adults and compared results to those obtained by RIP from polysomnography (PSG). In patients with OSA, a 1-night SSP recording using the PneaVoX sensor (Cidelec, Sainte-Gemmes-sur-Loire, France) was done. In parallel, PSG was performed according to American Academy of Sleep Medicine criteria. A subgroup of patients agreed to have Pes measurement in addition. Characterizations of apneas as obstructive, central, and mixed as well as hypopneas as central and obstructive were done by visual evaluation of SSP, RIP, and Pes in random order by two independent scores (S1 and S2). The sensitivity and specificity of characterization by SSP compared to RIP and to Pes were calculated. Synchronous recordings of SSP and PSG were analyzed from n = 34 patients with OSA (AHI 34.1 ± 24.2 events/h); 9 of them had synchronized Pes monitoring as well. Interscorer agreement for apnea characterization as obstructive, central, and mixed based on SSP, RIP, and Pes were found, with R2 values from 0.91-0.99. The sensitivity of SSP in apnea characterization with reference to RIP (S1/S2) was 91.5%/92.3% for obstructive, 82.7%/76.2% for central, and 87.4%/79.9% for mixed. The sensitivity of SSP in apnea characterization with reference to Pes was (S1/S2) 93.1%/92.1% for obstructive, 80.8%/81.6% for central, and 91.7%/90.8% for mixed. Hypopnea was only classified for the nine patients with Pes. This study demonstrated a good agreement in the detection of respiratory effort with the SSP signal using the PneaVoX sensor compared to the RIP belts signals as well as to the Pes signal. These findings were consistently found by two independent scorers. In summary, results suggest that SSP is a reliable signal for the classification of respiratory events and could be used as an additional tool for OSA characterization in clinical practice.
Read moreValidation d’un capteur sus-sternal pour la classification des apnées chez l’enfant