- Research Article
8
- 10.1016/j.compmedimag.2010.11.011
Revisiting stopping rules for iterative methods used in emission tomography
- Dec 31, 2010
- Computerized Medical Imaging and Graphics
- Hongbin Guo + 1 more +1
Publications from 2021 to 2026
Showing 3 of 3 papers
Revisiting stopping rules for iterative methods used in emission tomography
Compton Scattering in Clinical PET/CT With High Resolution Half Ring PET Insert Device
The integration of a high resolution PET insert into a conventional PET system can significantly improve the resolution and the contrast of its images within a reduced imaging field of view. For the rest of the scanner imaging field of view, the insert is a highly attenuating and scattering media. In order to use all available coincidence events (including coincidences between 2 detectors in the original scanner, namely the scanner-scanner coincidences), appropriate scatter and attenuation corrections have to be implemented. In this work, we conducted a series of Monte Carlo simulations to estimate the composition of the scattering background and the importance of the scatter correction. We implemented and tested the Single Scatter Simulation (SSS) algorithm for a hypothetical system and show good agreement between the estimated scatter using SSS and Monte Carlo simulated scatter contribution. We further applied the SSS to estimate scatter contribution from an existing prototype PET insert for a clinical PET/CT scanner. The results demonstrated the applicability of SSS to estimate the scatter contribution within a clinical PET/CT system even when there is a high resolution half ring PET insert device in its imaging field of view.
Read moreIterative circular conebeam CT reconstruction using fast hierarchical backprojection/reprojection operators
This is the first report on a new fast statistical iterative reconstruction algorithm for conebeam with a circular source trajectory, accelerated by InstaRecon's fast <i>O</i>(<i>N<sup>3</sup></i>log<i>N</i>) hierarchical cone beam backprojection1 and reprojection algorithms. We report on the results of image quality and run-time comparisons with iterative algorithms based on conventional backprojection and reprojection. We demonstrate that the iterative algorithm introduced here can provide image quality indistinguishable from an iterative algorithm using conventional BP/RP operators, while providing almost a 10x speedup in reconstruction rates. Combining the 10x algorithmic acceleration with additional hardware acceleration by FPGA, Cell, or GPU implementation, this work indicates the feasibility of iterative reconstruction algorithms for dose reduction and image quality improvement in routine CT practice, at competitive speeds and affordable cost.
Read more