Evaluation of Correlation Between Wear Resistance and Microhardness of Resin-based CAD/CAM Blocks
Aim: To examine the relation wear resistance and microhardness of composite block, hybrid block, resin composite to provide convenient argument to clinical usage of materials. Methods: Conventional resin composite (IPS Empress direct, Ivoclar Vivadent), hybrid ceramic block (Enamic, Vita) and composite blocks (Lava Ultimate, 3M), (Hc block, Shofu), (BrilliantCrios, Coltene), (Cerasmart, GC) were investigated. Specimens (n=12 for each group) (n=12 for each group) were loaded in a chewing simulator together a thermal cycling (49 N force, 240.000 cycles, 1.5 mm lateral movement, 1.7 Hz frequency). Specimens were scanned with a Las-20 (Laserscanner, SD Mechatronic) and Vickers microhardness (VHN) was determined (200 grf, 10 s). Statistical analysis was performed with using spearman correlation coefficient. Results: A negative correlation determined for all groups (r=- 0.83). Correlation was observed only composite block group between microhardness and wear resistance and no correlation was found hybrid block and resin composite. Conclusion: Correlation has found between surface microhardness and abrasive wear resistance of the IPS Empress direct,Enamic, Brilliant Crios, Hc block, Cerasmart, Lava Ultimate materials.