- Conference Article
7
- 10.2514/6.2019-2745
Determining Spectra of Aeroacoustic Sources from Microphone Array Data
- May 18, 2019
- Robert P Dougherty
Publications from 2021 to 2026
Showing 5 of 5 papers
Determining Spectra of Aeroacoustic Sources from Microphone Array Data
Application of synthetic array techniques for improved simulations of hot supersonic jet noise
The synthetic array technique has previously been used to provide insight for developing improved microphone array data processing techniques. In recent work, however, it has also been successfully applied to diagnose the source of unexpected (and nonphysical) tones which arose in unsteady computational fluid dynamics (CFD) simulations of hot supersonic jets. The insight obtained from this method has allowed the authors to rapidly arrive at a strategy that greatly improves the results. This success opens up additional areas where the synthetic array technique can find application.
Read moreApplication of Synthetic Array Techniques for Improved Simulations of Hot Supersonic Jet Noise
The synthetic array technique has previously been used to provide insight for developing improved microphone array data processing techniques. In recent work, however, it has also been successfully applied to diagnose the source of unexpected (and non-physical) tones which arose in unsteady CFD simulations of hot supersonic jets. The insight obtained from this method has allowed us to rapidly arrive at a strategy that greatly improves the results. This success opens up additional areas where the synthetic array technique can find application.
Read moreLinear Programming Acoustic Beamforming Versus Other Deconvolution Methods For A Full Scale 1.5 MW Wind Turbine
Measurement of muscle disease by quantitative second-harmonic generation imaging
Determining the health of muscle cells by in vivo imaging could impact the diagnosis and monitoring of a large number of congenital and acquired muscular or cardiac disorders. However, currently used technologies are hampered by insufficient resolution, lack of specificity, or invasiveness. We have combined intrinsic optical second-harmonic generation from sarcomeric myosin with a novel mathematical treatment of striation pattern analysis, to obtain measures of muscle contractile integrity that correlate strongly with the neuromuscular health of mice suffering from genetic, acquired, and age-related decline in skeletal muscle function. Analysis of biopsies from a pilot group of human volunteers suggests a similar power in quantifying sarcopenic changes in muscle integrity. These results provide the first strong evidence that quantitative image analysis of sarcomere pattern can be correlated with physiological function, and they invite the application of SHG imaging in clinical practice, either in biopsy samples or via microendoscopy.
Read more