E-205 In vitro evaluation of full-length, mr-safe interventional passive catheter markers at 3T
- Jul 01, 2022
- Journal of NeuroInterventional Surgery
- B Kilbride + 9 more +9
IntroductionMRI-guided intervention provides valuable functional information such as perfusion and diffusion that standard fluoroscopic guidance lacks. Recent studies have demonstrated utility in stroke treatment for multimodality X-ray and MR imaging suites. Yet, clinical adoption of MRI-guided intervention has lagged, and an absence of appropriate tooling could be a contributing factor. Prior work described a polymeric catheter featuring radiopaque markers doped with iron oxide nanoparticles (IONPs) as low-profile, MRI-visible passive markers. Here, we further investigate susceptibility artifacts in vitro at 0° and 90° with respect to B0. Marker separation was evaluated to identify a potential format for full-length visibility at 3.0T.MethodsPolymeric, 6.6 Fr guide catheter segments were built in a fabrication facility (Penumbra, Inc., Alameda, CA). Epoxy-based radiopaque ink was mixed with 9.1 wt% (w/w) iron(III) oxide (Fe2O3) nanoparticles of 20–40 nm diameter. Four circumferential marker bands ranging from 5 to 20 mm apart were applied in series starting 1 cm from the distal tip and cured at 20°C.15-cm segments submerged in copper sulfate solution (CuSO4, 1–2 g/L) were oriented parallel (0°) and orthogonal (90°) with respect to B0. At 0°, images were acquired in coronal/sagittal slice orientations on a 3.0T MRI scanner (MAGNETOM Skyra, Siemens Healthcare, Erlangen, Germany). At 90°, images were acquired in coronal/axial orientations to match image acquisition of 0°. Phase encoding direction was maintained parallel to the catheter major axes. T2-weighted turbo spin echo (TSE) and gradient echo (GRE) sequences were collected. Maximum artifact widths were evaluated per ASTM F2119–07, using ImageJ (http://imagej.nih.gov/ij).ResultsSusceptibility artifacts induced by the IONP-doped markers are shown (FIG. 1). 90° orientation produced worst-case artifacts in all sequences except the axial TSE. Furthermore, some artifacts could not be discerned at 90°. 20-mm separation yielded distinct artifacts without overlapping. E-205 Figure 1Susceptibility artifacts were assessed in vitr. Artifacts were evaluated per ASTM F2119–07 and measured with ImageJ software (red outlines). The phase encoding direction, as indicated by the black arrow, was oriented parallel to the major axis of the catheter segments. Blue dashed line = superimposed catheter onto MR images. Artifacts were measured while oriented parallel to B0 on a A) spin echo and B) gradient echo. The same measurement were collected at 90° with respect to B0 on a C) spin echo and D) gradient echo. E) Global artifact widths fro, all slices are presentedConclusionAlthough worst-case artifacts were observed at 90°, they remained acceptable for use in guide catheters. Additionally, 20-mm marker separation could provide distinct artifacts down the length of a catheter during MRI-guided interventions, despite anatomic tortuosity. The phantom used in this study was shallow, which limited the ability to distinguish between real artifacts and those arising from the solution-air interface. Hence, accuracy of the degree of increased artifact may warrant further investigation. This study simulated worst-case orientations in vitro; more data should be collected in vivo using real-time sequences to best evaluate artifacts during clinical use.DisclosuresB. Kilbride: None. C. Jordan: None. S. Ahn: 5; C; Siemens Medical Solutions USA Inc. K. Mueller: 5; C; Siemens Medical Solutions USA Inc. A. Chu: 5; C; Penumbra Inc. D. Barry: 5; C; Penumbra Inc.. T. Moore: None. A. Martin: None. M. Wilson: None. S. Hetts: None.
Read more