- Research Article
2
- 10.1016/j.radphyschem.2025.113318
Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator
- Feb 01, 2026
- Radiation Physics and Chemistry
- S.v Kutsaev + 9 more +9
Publications from 2021 to 2026
Showing 10 of 44 papers
Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator
Small scale electron linear accelerators for industrial applications
Virtual Critical Coupling in High-Power Resonant Systems
Power reflections are a fundamental challenge in high-power resonant systems, causing energy loss, limiting performance, and potentially damaging critical components. This problem is particularly acute in applications such as lower hybrid current drive (LHCD) for tokamak-based nuclear fusion, where efficient, stable power transfer to the plasma is paramount. In this work, we introduce and experimentally demonstrate the virtual critical coupling (VCC) mechanism, a nonmechanical method to achieve reflection-free excitation in high-power S-band resonators. VCC utilizes a temporally shaped excitation signal with a precise complex frequency, tailored to the resonator’s characteristics to enable complete energy absorption. Using a custom low-level RF system and a 5-MW S-band klystron, we conducted experiments from low power (32 mW) to high power (600 kW). The results demonstrate a greater than ninefold reduction in the reflection coefficient compared to conventional monochromatic excitation. This signal processing-based approach offers a robust path toward enhancing the efficiency and stability of high-power resonant systems, with significant implications for particle accelerators and the advancement of nuclear fusion energy.
Read moreHigh-Voltage Pulsed Power Generator for Beam Injection Systems
Beam injection systems in hadron colliders require kickers generating ±kV peak voltages into a 50Ω impedance, with peak currents of 1000 A and sub- 10 ns rise and fall times. This paper presents a novel high-voltage pulse power generator utilizing a dis-tributed pulser architecture. It combines gallium nitride (GaN) transistors in a Marx to-pology with an inductive adder, achieving nanosecond-scale switching speeds and high-power efficiency. Compared to other solutions such as based on MOSFETs or fast ionization dynistors, our development offers superior peak and average power performance, reduced system complexity, and enhanced reliability, marking a significant step forward in high-voltage pulse generation for accelerator applications.
Read moreCommissioning of a photocathode and interaction laser system at RadiaBeam compact inverse Compton light source
New generation bunch shape monitor for ion accelerators.
Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. In this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.
Read moreSub-THz passive detector performance evaluation with RadiaBeam photoinjector
High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system.
Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. The NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C3) with a peak rf power level up to 16.45MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C3. The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.
Read moreFeasibility study of high-power electron linac for clinical X-ray ROAD-FLASH therapy system
Introduction:This study examines how a practical source of X-ray radiation, capable of delivering unprecedented X-ray of 100 Gy/s at 1 m for X-ray FLASH radiotherapy can be designed.Methods:We proposed the design of a linac, capable of accelerating 18 MeV 8 mA electron beam with further conversion to bremsstrahlung X-rays. The design is based on L-band traveling wave accelerating structures with high power efficiency, operating in a short-burst/long-pulse regime that allows operating power supply in a regime, beyond its specifications.Results:This study demonstrates the feasibility of a high-power linac for a clinical X-ray FLASH therapy system, using detailed analysis and simulations. Despite ~500x higher output than a standard clinical linac, the design utilizes available accelerator components for maximal practicality.Discussion:Recent studies have demonstrated that the FLASH effect that allows to effectively kill tumor cells while sparing normal tissue occurs when large dose rates (≥40 Gy/s) are delivered in less than 1 s. Photons are very attractive since modest energies of several MeV are needed, which can be achieved with compact and cost-efficient accelerators. However, since the efficiency of electron-to-photon conversion is only a few percent, the required beam intensity must be an order of magnitude higher than that state-of-the-art accelerators can provide. The proposed ROAD-FLASH accelerator layout allows achieving both the FLASH dose rate and superior dose conformity, comparing to the similar projects. The current paper focuses on providing a technical roadmap for building an economical and practical linear accelerator for ROAD X-ray FLASH delivery.
Read moreUltralightweight Power System for Human-Portable Linac-Based X-Ray Sources
Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. In this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.