- Research Article
- 10.1016/j.ijpt.2025.100848
HEAD AND NECK REIRRADIATION: AN ANALYSIS OF THE PROTON COLLABORATIVE GROUP
- Dec 01, 2025
- International Journal of Particle Therapy
- Homan Mohammadi + 19 more +19
Publications from 2021 to 2026
Showing 10 of 43 papers
HEAD AND NECK REIRRADIATION: AN ANALYSIS OF THE PROTON COLLABORATIVE GROUP
AAPM working group on cybersecurity report 438: A white paper on cybersecurity management for business continuity in radiology and radiation therapy
A growing number of clinics have experienced disruptions of clinical services due to cyberattacks. To provide continuity of care, medical physicists should work with Information Technology (IT) staff to develop a business continuity plan. Such planning requires the participation of many stakeholders and should include the development of policies and procedures that not only make the clinic more cyber‐resilient but also address patient safety and ethics concerns. This report discusses the business continuity planning considerations for radiology and radiation oncology.
Read moreWater equivalent thickness and density overrides for readily available oral cavity spacer materials in proton therapy
Reducing Radiation Dermatitis for PBS Proton Therapy Breast Cancer Patients Using SpotDelete
PurposeThe purpose of this work was to reduce the severity of radiation dermatitis for breast cancer patients receiving pencil beam scanning proton therapy. The hypothesis was that eliminating proton spots (SpotDelete) in the 0.5 cm skin rind would reduce the potentially higher relative biological effectiveness (RBE) known to occur at the Bragg Peak. Patients and MethodsOur center has been using an in-house developed Python script in RayStation since 2021 to remove spots from the skin rind of breast patients. In this work, we retrospectively reviewed the on-treatment visit data from a cohort of breast patients treated with hypofractionation (16 fractions) before this technique (MinDepth) and after (SpotDelete) to acquire the physician-reported radiation dermatitis scores. We evaluated the delivered treatment plans, calculating the linear energy transfer (LET) and applying 3 variable RBE models, Carabe-Fernandez, Wedenberg, and McNamara. An α/β of 10 was assumed for the skin. ResultsIn the MinDepth cohort (n = 28), grade 1, 2, and 3 dermatitis accounted for 57%, 36%, and 7% of the cases, respectively. For SpotDelete (n = 27), the incidence rate of grade 1 and 2 acute radiation dermatitis was 67% and 37%, respectively. There were 0 instances of grade 3 dermatitis observed in the SpotDelete cohort. The onset of radiation dermatitis in the SpotDelete cohort was delayed compared to MinDepth, occurring 1 week later in the course of treatment. There was no significant difference in LET or in any of the variable RBE models when analyzing the 0.5 cm skin rind between the cohorts. ConclusionDespite the lack of correlation in LET or RBE, SpotDelete has been shown to reduce the severity and onset of radiation dermatitis. Possibly, more research into the α/β for skin and RBE models based on skin cell lines could provide insight into the efficacy of the SpotDelete technique.
Read moreO 27 - Reducing radiation dermatitis severity in breast cancer patients using a spot-delete technique in pencil beam scanning proton therapy
Intradermal testing and serum allergen-specific IgE-testing in cats with naturally occurring feline bronchial disease.
While feline asthma (FA) is considered to be of allergic origin, the etiology of feline chronic bronchitis (CB) to date is unknown. Aim of the study was to compare the results of intradermal testing (IDT) and serum testing for allergen-specific immunoglobulin E (SAT) in cats diagnosed with FA and CB. Twenty-seven client-owned cats with clinical signs, suggestive of feline inflammatory bronchial disease (FBD) were prospectively enrolled in the study. Patients were assigned to 3 groups based on results of bronchoalveolar-lavage-fluid (BALF)-cytology: FA (n=8), CB (n=10), or cats with a physiological BALF cytology (PB; n=9). A standardized IDT for 27 allergens was performed in all cats. In addition, allergen-specific IgE was measured in serum samples using an FcεRIα-ELISA. The number of positive reactions in both tests was compared between groups, and agreement between test results of both tests was evaluated. Regarding the number of positive reactions, no statistically significant difference was detected between groups in IDT (p=0.65) and SAT (p=0.51). When comparing the 2 test systems, a weak correlation was found for the allergens Tyrophagus putrescentiae (k=0.256), Dermatophagoides farinae (k=0.276), and rye (k=0.273). The most commonly observed reactions were to house dust mites, storage mites, rye and nettle in IDT and to sheep sorrel, storage mites, and house dust mites in SAT. IDT and SAT in cats with feline inflammatory bronchial disease (FBD) cannot be used interchangeably for allergen detection. Sensitization to environmental allergens can occur in cats with and without airway inflammation. Therefore, a positive test result should always be assessed in context with clinical signs and allergen exposure.
Read moreJournal impact factors and the future of open access publishing
Racial Disparities in COVID-19 Outcomes Among Black and White Patients With Cancer
Non-Hispanic Black individuals experience a higher burden of COVID-19 than the general population; hence, there is an urgent need to characterize the unique clinical course and outcomes of COVID-19 in Black patients with cancer. To investigate racial disparities in severity of COVID-19 presentation, clinical complications, and outcomes between Black patients and non-Hispanic White patients with cancer and COVID-19. This retrospective cohort study used data from the COVID-19 and Cancer Consortium registry from March 17, 2020, to November 18, 2020, to examine the clinical characteristics and outcomes of COVID-19 in Black patients with cancer. Data analysis was performed from December 2020 to February 2021. Black and White race recorded in patient's electronic health record. An a priori 5-level ordinal scale including hospitalization intensive care unit admission, mechanical ventilation, and all-cause death. Among 3506 included patients (1768 women [50%]; median [IQR] age, 67 [58-77] years), 1068 (30%) were Black and 2438 (70%) were White. Black patients had higher rates of preexisting comorbidities compared with White patients, including obesity (480 Black patients [45%] vs 925 White patients [38%]), diabetes (411 Black patients [38%] vs 574 White patients [24%]), and kidney disease (248 Black patients [23%] vs 392 White patients [16%]). Despite the similar distribution of cancer type, cancer status, and anticancer therapy at the time of COVID-19 diagnosis, Black patients presented with worse illness and had significantly worse COVID-19 severity (unweighted odds ratio, 1.34 [95% CI, 1.15-1.58]; weighted odds ratio, 1.21 [95% CI, 1.11-1.33]). These findings suggest that Black patients with cancer experience worse COVID-19 outcomes compared with White patients. Understanding and addressing racial inequities within the causal framework of structural racism is essential to reduce the disproportionate burden of diseases, such as COVID-19 and cancer, in Black patients.
Read moreSU‐E‐J‐148: Evaluating Tumor Response with a Commercially Available Deformable Registration System
Purpose:The purpose of this study is to present a method for evaluating the response to treatment using a commercially available deformable image registration software package (Velocity Medical Systems) and repeat PET/CT imaging. This technique can be used to identify volumes that are risk for tumor recurrence.Methods:Response to treatment was evaluated using PET/CT images acquired prior‐to and post‐treatment for radiation therapy patients treated with concurrent chemotherapy. Velocity (Version 3.0.1) was used to deform the initial PET/CT to the post treatment PET/CT. The post‐treatment PET images were then subtracted from the pre‐treatment PET images. The resulting re‐sampled image is a three‐dimensional SUV difference map that shows pixels with increasing SUV values. SUV values increases greater than 2.5 in the post treatment images were identified for additional follow‐up.Results:A total of 5 Lung patients were analyzed as part of this study. One lung patient in the cohort had an SUV increase of +3.28 that was identified using the SUV difference map. This volume of increased uptake was located outside the treatment field and adjacent to the 35 Gy isodose line. The remaining four patients all had SUV decreases inside the planning target volume, and no unexpected areas of increase outside the irradiated volumes. All five patients were analyzed using standard tools inside the Velocity application.Conclusion:The response to treatment can easily be measured using serial PET/CT images and a commercially available deformable image registration. This provides both the radiation oncologists and medical oncologists with a quantitative assessment of their treatment to use in patient follow‐up.
Read moreWE‐B‐BRA‐02: QA of Helical Tomotherapy TG‐148
Helical tomotherapy is a relatively new modality with integrated treatment planning and delivery hardware for radiation therapy treatments. In view of the uniqueness of the hardware design of the helical tomotherapy unit and its implications in routine clinical practice, the Therapy Physics Committee (TPC) of the American Association of Physicists in Medicine (AAPM) commissioned Task Group 148 (TG‐148) to review this modality and make recommendations for quality assurance related methodologies. This report summarizes the findings of the Task Group and aims to provide the practicing clinical medical physicist with the insight into the technology that is necessary to establish an independent and comprehensive quality assurance program for a helical tomotherapy unit. In this task group report an overview of the TomoTherapy system and its unique aspects is provided. Delivery, imaging, and treatment planning quality assurance are discussed in three separate chapters of this report. Lastly quality assurance aspects are summarized according to their recommended frequency.
Read more