- Research Article
- 10.1016/j.sleep.2025.107995
Comparison of SONNO® home sleep test with in-laboratory polysomnography in the diagnosis of obstructive sleep apnea syndrome
- Feb 01, 2026
- Sleep Medicine
- S Sharma + 5 more +5
Publications from 2021 to 2026
Showing 10 of 10 papers
Comparison of SONNO® home sleep test with in-laboratory polysomnography in the diagnosis of obstructive sleep apnea syndrome
Sleep Quality with EPAP Enhanced Novel Mandibular Advancement Device versus Continuous Positive Airway Pressure in Severe Obstructive Sleep Apnea
Advances in Bioengineering and Biomedical Science Research, list of open access journals, open access, open access journals, open access publication, open access publisher, open access publishing, open access journal articles, Opast Publishing Group, Articles in Press
Read moreP070 Efficacy of the ExVent Accessory with the O2Vent Optima Oral Appliance in the Treatment of Obstructive Sleep Apnea – A Clinical Trial
Abstract Introduction The study assessed the efficacy of oral appliance device O2Vent Optima and ExVent, an oral Expiratory Positive Airway Pressure (EPAP) accessory in the treatment of OSA. Methods A prospective, open-label study conducted at 3 sites in mild to moderate OSA (AHI ≥ 5 and ≤ 30). Screening Phase A diagnostic in-lab PSG study confirmed a diagnosis of mild to moderate OSA. Treatment I Subjects used O2Vent Optima for 6 weeks and underwent a PSG sleep night while using the O2Vent Optima. Treatment II Subjects used O2Vent Optima + ExVent for 6 weeks and underwent a PSG sleep night while using the O2Vent Optima + ExVent Primary Effectiveness Measure: Change in AHI between baseline vs. O2Vent Optima MAD vs. O2Vent Optima + ExVent Results Treatment with Optima, Optima + ExVent reduced AHI from 22.5±6.4/hr to 12.6±4.5/hr to 5.9±2.7 (p< 0.005 baseline vs. Optima and Optima + ExVent; p<0.05 Optima MAD vs. Optima + ExVent). Average reduction in AHI with Optima was 43% and with Optima + ExVent was 72%. The lowest oxygen during sleep increased from 84.6±2.7% to 88.6±2.9% to 91.6±3.2% (p< 0.005 baseline vs. Optima and Optima + ExVent; p<0.05 Optima vs. Optima + ExVent). During the trial patients on treatment with Optima and Optima + ExVent demonstrated no excessive adverse events or device malfunction. Conclusion Treatment with O2Vent Optima and O2Vent Optima + ExVent significantly improved OSA compared to the baseline. Even greater benefit was observed with addition of ExVent to the Optima in mild to moderate OSA.
Read moreSleep and body clock problems in patients with obsessive–compulsive disorder
Patient safety, resident well-being and continuity of care with different resident duty schedules in the intensive care unit: a randomized trial
Shorter resident duty periods are increasingly mandated to improve patient safety and physician well-being. However, increases in continuity-related errors may counteract the purported benefits of reducing fatigue. We evaluated the effects of 3 resident schedules in the intensive care unit (ICU) on patient safety, resident well-being and continuity of care. Residents in 2 university-affiliated ICUs were randomly assigned (in 2-month rotation-blocks from January to June 2009) to in-house overnight schedules of 24, 16 or 12 hours. The primary patient outcome was adverse events. The primary resident outcome was sleepiness, measured by the 7-point Stanford Sleepiness Scale. Secondary outcomes were patient deaths, preventable adverse events, and residents' physical symptoms and burnout. Continuity of care and perceptions of ICU staff were also assessed. We evaluated 47 (96%) of 49 residents, all 971 admissions, 5894 patient-days and 452 staff surveys. We found no effect of schedule (24-, 16- or 12-h shifts) on adverse events (81.3, 76.3 and 78.2 events per 1000 patient-days, respectively; p = 0.7) or on residents' sleepiness in the daytime (mean rating 2.33, 2.61 and 2.30, respectively; p = 0.3) or at night (mean rating 3.06, 2.73 and 2.42, respectively; p = 0.2). Seven of 8 preventable adverse events occurred with the 12-hour schedule (p = 0.1). Mortality rates were similar for the 3 schedules. Residents' somatic symptoms were more severe and more frequent with the 24-hour schedule (p = 0.04); however, burnout was similar across the groups. ICU staff rated residents' knowledge and decision-making worst with the 16-hour schedule. Our findings do not support the purported advantages of shorter duty schedules. They also highlight the trade-offs between residents' symptoms and multiple secondary measures of patient safety. Further delineation of this emerging signal is required before widespread system change. ClinicalTrials.gov, no. NCT00679809.
Read moreUpdate in Sleep and Control of Ventilation 2008
Update in Sleep and Control of Ventilation 2006
Pain in Humans, Sleep Disturbances
Variants of the orexin2/hcrt2 receptor gene identified in patients with excessive daytime sleepiness and patients with Tourette's syndrome comorbidity.
The orexin-2/hypocretin-2 (OX2R) receptor gene is mutated in canine narcolepsy and disruption of the prepro-orexin/hypocretin ligand gene results in both an animal model of narcolepsy and sporadic cases of the human disease. This evidence suggests that the structure of the OX2R gene, and its homologue, the OX1R gene, both members of the G protein-coupled receptor (GPCR) family, and the gene encoding the peptide ligands, the prepro-orexin/hypocretin gene, may be variables in the etiology of sleep disorders. We report a single stranded conformational polymorphism (SSCP) analysis of the coding regions of these genes in idiopathic sleep disorder patients diagnosed with excessive daytime sleepiness (EDS) (n = 28), narcolepsy (n = 28), Tourette's syndrome/chronic vocal or motor tic disorder (n = 70), and control subjects (n = 110). Two EDS patients showed a Pro11Thr change. One Tourette's syndrome patient was found to have a Pro10Ser alteration. The Pro10Ser and Pro11Thr variants were not found in non-disease populations. Analysis of the ability of the mutant receptors to mobilize calcium compared to the wild-type receptor in response to orexin agonists indicated that they resulted in decreased potency at high (etaM) concentrations of orexin ligands. Further work is warranted to study the variability of the orexin/hypocretin system in a variety of disorders characterized by EDS.
Read more