• Home
  • Search
  • Исследование точности определения места повреждения воздушных линий по данным от устройств синхронизированных векторных измерений различных классов и производителей
  • https://doi.org/10.17588/2072-2672.2024.1.044-052Copy DOI Icon

Исследование точности определения места повреждения воздушных линий по данным от устройств синхронизированных векторных измерений различных классов и производителей

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

The technology of synchronized phasor measurements has been widely used in the Russian power system to analyze the parameters of steady-state electrical power modes and to record electro-mechanical transient processes. Issues on fault location based on synchronized phasor measurements have mainly been discussed in foreign publications. A significant drawback of most research papers on this issue is simplified modeling of both overhead lines and current and voltage measurement channel as well as digital filters of phasor measurement units (PMUs). The goal of this research is to develop a fault location algorithm based on synchrophasor measurements and to study its accuracy by using specialized equipment including a real-time digital simulator (RTDS), PONOVO current and voltage amplifiers and production-grade PMUs. A PMU-based double-ended fault location algorithm is developed using long-line equations and well-known electromagnetic transient theory concepts. Currents and voltage oscillograms of both overhead transmission line ends are modelled in the MATLAB/Simulink software package. These oscillograms are saved as COMTRADE files and played back using the RTDS hardware and all-in-one software package RSCAD. In addition, the study uses two production-grade PMUs, the first one is TPA-02, and the second one is a merging unit ENMU acting as a PMU, thus imitating PMUs at the line terminals. To time-align all the measurements and to aggregate PMU data frames, various auxiliary software such as PMU Connection Tester, and hardware is used. A double-ended fault location (FL) method utilizing synchrophasors under a fault has been developed. The method is based on an overdetermined system of nonlinear equations that describes physical processes in an overhead power line and can be applied under various fault types. An integrated study of the efficiency of the developed FL method has been conducted. FL errors have been computed using production-grade PMUs ENMU and TPA-02, along with the RTDS and other equipment. The authors have considered the case of configuring PMUs of different classes at the overhead line terminals, and different phasor reporting rates as well. The conducted experiments make it possible to reveal that the fault location errors do not exceed the thresholds imposed by the standard STO 56947007-29.120.70.241-2017 in 88 % of all the analyzed fault scenarios. The developed FL method makes it possible to achieve the accuracy required by regulatory guide in calculating the distance to the short circuit point in most of the cases examined. Based on the results of numerical experiments for various types of fault cases, it can be concluded that the PMU class and phasor reporting rate do not have a significant impact on the FL accuracy, provided that the fault duration is enough for the PMU filter to approach a steady output.

Similar Papers
  • Research Article
  • Citations9

Wide‐area fault location method considering gross measurement errors

  • Sep 20, 2017
  • IET Generation, Transmission & Distribution
  • Seyed Ali Hosseini +2
  • Research Article
  • Citations1

Многофакторное автоматизированное исследование методов определения места повреждения на модели воздушной линии электропередачи 500 кВ

  • Aug 31, 2023
  • Vestnik IGEU
  • D.S Sharygin +2
  • Conference Article
  • Citations1

Fault Location on Power System Transmission Lines using Synchronized and Unsychronized Data

  • Aug 23, 2021
  • 2021 IEEE PES/IAS PowerAfrica
  • Sindiswa Ndamase +2
  • Research Article
  • Citations7

MTL-TRANSFER: Leveraging Multi-task Learning and Transferred Knowledge for Improving Fault Localization and Program Repair

  • Jun 27, 2024
  • ACM Transactions on Software Engineering and Methodology
  • Xu Wang +7
  • Conference Article
  • Citations12

A new phase measurement unit (PMU) based fault location algorithm for double circuit lines

  • Jan 01, 2004
  • Li Shengfang
  • Conference Article
  • Citations2

Analysis of Synchrophasor Data Captured Under Faults on 500 kV Overhead Lines Through Available Transient Waveforms

  • Oct 20, 2022
  • Igor E Ivanov +1
  • Conference Article
  • Citations4

Analysis of μPMU Noise Characteristics and Its Influence on Distribution Network Fault Location

  • Nov 01, 2018
  • Ren Xinyu +3
  • Conference Article
  • Citations51

A novel fault location method and algorithm for DC distribution protection

  • Oct 01, 2016
  • Xianyong Feng +2
  • Research Article
  • Citations121

A Novel Fault Location Method and Algorithm for DC Distribution Protection

  • May 01, 2017
  • IEEE Transactions on Industry Applications
  • Xianyong Feng +2
  • Research Article
  • Citations1

An accurate fault location method for distribution network considering the cumulative deviation of wave speed

  • Apr 01, 2025
  • Journal of Physics: Conference Series
  • Beiyuan Liu
  • Research Article
  • Citations9

Improved Fault Detection and Location Method in Three-Phase Distribution Networks Leveraging Traceable PMU Measurements

  • Jan 01, 2025
  • IEEE Transactions on Instrumentation and Measurement
  • Paolo Attilio Pegoraro +5
  • Conference Article
  • Citations2

Development of a Fault Location Method on an Overhead Power Line with a Branch

  • Sep 24, 2021
  • Galina Filatova +1
  • Research Article
  • Citations75

Validation of a PMU‐based fault location identification method for smart distribution network with photovoltaics using real‐time data

  • Oct 02, 2018
  • IET Generation, Transmission & Distribution
  • Muhammad Usama Usman +1
  • Research Article
  • Citations15

Optimal placement of voltage measurements for wide area fault location observability considering the uncertainty of network parameters

  • Aug 07, 2018
  • Electric Power Systems Research
  • Nader Jalali Marand +2
  • Research Article

Fault location on overhead power lines using multi-hypothesis sequential analysis and the Armitage algorithm

  • Dec 21, 2024
  • Izvestiâ Akademii nauk SSSR. Ènergetika
  • A L Kulikov +2