• Home
  • Search
  • Разрешающая способность и линейное разрешение для оценки качества и проектирования аэрокосмических систем дистанционного зондирования Земли
  • Cite Icon1
  • https://doi.org/10.30894/issn2409-0239.2022.9.1.9.29Copy DOI Icon

Разрешающая способность и линейное разрешение для оценки качества и проектирования аэрокосмических систем дистанционного зондирования Земли

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The article examines the concepts of resolving power and spatial resolution (linear, limiting, diffraction) in analog (photographic) and digital (optoelectronic) aerospace ERS systems. It was found that the foreign criterion for assessing the limiting geometric resolution of the remote sensing system of remote sensing on the terrain, the GSD criterion, is inadequate for assessing the linear spatial resolution. Its use in the design of the remote sensing system impedes the matching of the lens and the digital detector according to the Nyquist criterion. This leads to information and financial losses. It is shown that the GSD criterion characterizes the minimum size of an object perceived by the remote sensing system on the earth’s surface, and not the minimum distance between two separately observed (resolvable) objects, that is, the concept of “limiting resolution” is closer to the concept of “sharpness” of the image, and not to the concepts of “resolution” and “spatial resolution”, and therefore cannot be used to assess the spatial resolution and design of the remote sensing system. It was found that to assess the quality and design of ERS systems, it is necessary to use the Russian criterion for assessing the instrumental linear spatial resolution of ERS systems on the terrain, the RSS criterion, which gives a real assessment of the spatial resolution, allows the projected ERS systems to be matched according to the Nyquist criterion with a design excellence factor equal to one (K = 1), and provides the ability to achieve the diffraction limit of the linear spatial resolution of the ERS systems on the terrain. In order to avoid further erroneous use of the foreign GSD criterion in the Russian Federation, it is proposed to standardize the domestic RSS criterion with the Russian GOST and use it to assess the quality and design of remote sensing systems.

Similar Papers
  • Conference Article
  • Citations10

An improved anger detector approach for PET with high resolution and sensitivity

  • Oct 16, 2004
  • P Vaska +8
  • Research Article
  • Citations48

Comparison of Global Databases for Disaster Loss and Damage Data

  • Nov 01, 2018
  • Journal of Disaster Research
  • Kana Moriyama +2
  • Research Article

Size-estimates for distributions of microscopic damage from fracture tests on fiber-reinforced polymer-matrix composites: Insight from acoustic emission monitoring

  • Oct 01, 2025
  • IOP Conference Series: Materials Science and Engineering
  • Andreas J Brunner +2
  • Research Article
  • Citations14

Comment on “Resolving the 180° Ambiguity in Solar Vector Magnetic Field Data: Evaluating the Effects of Noise, Spatial Resolution, and Method Assumptions”

  • Jul 27, 2011
  • Solar Physics
  • Manolis K Georgoulis
  • Research Article
  • Citations543

Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution

  • Jan 01, 1999
  • Physics in Medicine & Biology
  • Craig S Levin +1
  • Research Article
  • Citations16

Super resolution PLIF demonstrated in turbulent jet flows seeded with I2

  • Jan 04, 2018
  • Optics & Laser Technology
  • Wenjiang Xu +2
  • Conference Article
  • Citations4

X-ray imaging of human brain tissue down to the molecule level

  • Jul 08, 2021
  • Bert Müller +5
  • Research Article
  • Citations5

Scalp surface Laplacian potential monitoring system based on novel hydrogel active tri-polar concentric ring electrodes

  • Oct 23, 2024
  • Sensors and Actuators: A. Physical
  • Haoqiang Hua +6
  • Single Report
  • Citations2

Performance comparison of streak camera recording systems

  • Jul 01, 1995
  • M Derzon +1
  • Research Article
  • Citations1

Micro-Angiographic Fluoroscope: Comparison for Different Input Phosphors

  • Jun 01, 2014
  • IEEE Transactions on Nuclear Science
  • Amit Jain +2
  • Conference Article
  • Citations3

Centimeter spatial resolution of distributed optical fiber sensor for structural health monitoring

  • Nov 16, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Lufan Zou +4
  • Abstract

OA24 Magnetic resonance imaging of the trabecular bone microarchitecture at 3 Tesla - comparison with 1.5 Tesla

  • Sep 01, 2004
  • Journal de Radiologie
  • C Phan +5
  • Research Article
  • Citations23

Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

  • Jan 19, 2006
  • European Journal of Radiology
  • Alexander Lembcke +7
  • Book Chapter
  • Citations2

Fast In Vivo High-Resolution Diffusion MRI of the Human Cervical Spinal Cord Microstructure

  • May 30, 2018
  • René Labounek +11
  • Research Article
  • Citations52

Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites

  • Jun 01, 2016
  • Journal of Neural Engineering
  • F Pothof +7