• Home
  • Search
  • 1012-P: Study of Insulin Stability Impact on Pump Therapy: Test Model Development
  • Cite Icon5
  • https://doi.org/10.2337/db20-1012-pCopy DOI Icon

1012-P: Study of Insulin Stability Impact on Pump Therapy: Test Model Development

  • Jun 1, 2020
  • Diabetes
  • Sarnath Chattaraj +3 more
Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Objective: Develop a test methodology for evaluating the reason for infusion set (IS) failure in persons with diabetes using insulin pump therapy (Continuous Sub-cutaneous Insulin Infusion, CSII). Insulin stability (physical, chemical, and microbiological) and/or the loss of preservatives in the infusate are thought to play significant roles in shortening IS wear time. In-vitro and in-vivo methods were used to assess the cause(s) site inflammation and the loss of preservatives. Method: Fast-acting insulin (insulin aspart and lispro) were pumped through different infusion sets (>4) under simulated-use conditions. The pumped insulin and non-pumped insulin controls were characterized for physical, chemical, and microbiological properties. The pumped insulin, combined with fibrinogen (an initiator for material foreign body responses), were tested in murine macrophage cell culture for inflammatory responses. The corresponding infusion sets were tested in vivo in a diabetic porcine model to determine IS wear-time. Result: Pumped insulins in ≥8 insulin/IS combinations met corresponding criteria in USP insulin monographs, indicating no significant chemical changes. Lower preservative content was found to increase insulin aggregates in-vitro/in-vivo. Pro-inflammatory cytokines (MIP-1α, and MCP-1) increased significantly in the inflammatory in-vitro model. The IS wear-time was shortened from 4.9±0.3 days (control) to 1.7±0.3 days (p<0.0001) with lower preservative content (<50% per label claim). Conclusion: Preliminary findings from in-vitro and in-vivo test model development indicate that macrophage number, the inflammatory response, and device wear time were significantly impacted by loss of preservative and trace aggregates/particles. The new test methodology can further our understanding as to how to improve IS wear time. Disclosure S. Chattaraj: Employee; Self; Medtronic. G. Zhang: None. E. Anselmo: Employee; Self; Medtronic. J.C. Fusselman: None.

Similar Papers
  • Research Article
  • Citations34

Compatibility and Safety of Ultra Rapid Lispro with Continuous Subcutaneous Insulin Infusion in Patients with Type 1 Diabetes: PRONTO-Pump Study.

  • Dec 31, 2020
  • Diabetes Technology & Therapeutics
  • Bruce W Bode +6
  • Research Article
  • Citations7

A Continuous Subcutaneous Insulin Infusion Needle Break

  • Oct 01, 2015
  • Clinical Diabetes : A Publication of the American Diabetes Association
  • Minu M George +2
  • Research Article
  • Citations2

Comparison of Continuous Subcutaneous Insulin Infusion versus Basal/Bolus Insulin Injections for Treatment of Type 1 Diabetes in Clinical Practice

  • Mar 01, 2009
  • Journal of Diabetes Science and Technology
  • Anjana Myneni +5
  • Research Article
  • Citations24

Better Postprandial Glucose Stability During Continuous Subcutaneous Infusion with Insulin Aspart Compared with Insulin Lispro in Patients with Type 1 Diabetes

  • Dec 01, 2008
  • Diabetes Technology & Therapeutics
  • Paolo Di Bartolo +10
  • Research Article
  • Citations2

997-P: Testing a Novel Infusion Set for Extended Wear Duration

  • Jun 01, 2020
  • Diabetes
  • Bruce A Buckingham +6
  • Research Article
  • Citations39

Use of continuous subcutaneous insulin infusion (insulin pump) therapy in the hospital: a review of one institution's experience.

  • Nov 01, 2008
  • Journal of Diabetes Science and Technology
  • Brenda J Leonhardi +8
  • PDF
  • Research Article
  • Citations336

Clinical effectiveness and cost-effectiveness of continuous subcutaneous insulin infusion for diabetes: systematic review and economic evaluation.

  • Feb 01, 2010
  • Health technology assessment (Winchester, England)
  • E Cummins +6
  • Research Article
  • Citations37

Use of rapid-acting insulin analogues in the treatment of patients with type 1 and type 2 diabetes mellitus: Insulin pump therapy versus multiple daily injections

  • Jan 01, 2007
  • Clinical Therapeutics
  • Bruce W Bode
  • Research Article

Advances in infusion sets and insulin pumps in diabetes care

  • Sep 02, 2016
  • British Journal of Healthcare Management
  • Anne Phillips
  • Research Article
  • Citations29

Insulin Pump and CGM Usage in the United States and Germany: Results of a Real-World Survey With 985 Subjects.

  • Jun 12, 2015
  • Journal of Diabetes Science and Technology
  • John Walsh +4
  • Research Article
  • Citations41

Point: Are Insulin Pumps Underutilized in Type 1 Diabetes? Yes

  • May 26, 2006
  • Diabetes Care
  • John C Pickup
  • Research Article
  • Citations1

61-Year-Old Man With Nausea and Vomiting

  • Dec 01, 2021
  • Mayo Clinic Proceedings
  • Goyal Umadat +2
  • Research Article
  • Citations12

The effect of DAFNE education, continuous subcutaneous insulin infusion, or both in a population with type 1 diabetes in Scotland.

  • Feb 06, 2020
  • Diabetic Medicine
  • J A Mcknight +10
  • Research Article
  • Citations88

Continuous subcutaneous insulin infusion with short‐acting insulin analogues or human regular insulin: efficacy, safety, quality of life, and cost‐effectiveness

  • Mar 01, 2004
  • Diabetes/Metabolism Research and Reviews
  • Régis Pierre Radermecker +1
  • Research Article

Access to insulin pump therapy and continuous glucose monitoring - is it an even playing field?

  • Jul 15, 2012
  • Diabetic Medicine
  • G A Hitman
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.