Long-term stability of HIV-1 antibody in dried blood spot samples and eluates.
Antibody tests have been extensively used to monitor the prevalence and changes in the HIV-1 epidemic in the general population. In the UK, unlinked anonymous testing of neonatal dried blood spot (DBS) samples has provided unbiased estimates of the prevalence of maternal infection in women with live births [1]. Quality assurance and quality control procedures are necessary to ensure consistent tests resulting in unbiased estimates of prevalence in population-based surveys. As part of the quality assurance programme for neonatal screening laboratories, Centers for Disease Control and Prevention (CDC, Atlanta, USA) has produced blinded (negative and positive) samples which have been sent to laboratories worldwide for 25 years [2]. In addition, CDC has supplied HIV-1-positive quality control DBS specimens produced to a set standard to measure assay performance. As part of the national unlinked anonymous surveillance programme covering the former Thames regions of England [3], we have received HIV-1 quality assurance samples every quarter and quality control samples every 6 months for over 20 years, and have a 100% record of correctly identifying HIV-1 antibody-positive DBS CDC quality assurance samples. In total, we have tested over 3.5 million neonatal DBS samples for HIV-1 maternal antibody. DBS samples are eluted overnight at 4°C in phosphate-buffered saline-Tween 80 and sodium azide (0.0005%). These eluted samples are then tested by making a 1 : 5 dilution in Treponema pallidum particle agglutination (TPPA) buffer into a V-well test plate and adding a 1 : 10 dilution of Serodia HIV-1 gelatin particles (Fujirebio Inc., Tokyo, Japan). After settlement for 4 h at room temperature, the plates are read over a light box, a positive result being shown by a characteristic agglutination pattern, and a negative result by a button of settled particles. Positive samples are titrated to an end point. Although DBS samples containing HIV-1 antibodies have been reported to be stable over time, even in unsuitable climatic and storage conditions [4,5], to our knowledge, no study has re-analysed them after a period of more than 5 years [6]. The stability of DBS samples over longer periods could prove useful for retrospective testing of antibodies for other conditions using long-term stored DBS samples [7]. To analyse antibody stability, we selected the oldest available DBS samples and eluates stored in our laboratory and re-tested them for HIV-1 antibodies. Firstly, we examined four DBS CDC quality control high positive control samples produced in 1991 and stored continuously in a freezer at −20°C in gas-impermeable bags with a dessicant. When tested in February 2014, all of them had the same titres as those measured in 1991. Secondly, we retested 12 DBS samples produced between October 1997 and October 1999 by the CDC quality assurance programme. The samples had been stored at 4°C in a laboratory fridge for at least 14 years and were originally tested when they reached our laboratory. They were re-tested in November 2013 and all 12 samples were HIV-positive; nine had the same titre, two increased by two dilutions, and one decreased by two dilutions. Finally, we re-tested 98 HIV-1-positive neonatal DBS eluates available from the unlinked anonymous anti-HIV-1 survey in pregnant women in North Thames which were originally tested in the first three quarters of 2003 and stored for over 9 years at −20°C. As we were interested in antibody degradation, we selected the DBS eluates with the lowest titres among the oldest specimens stored in our laboratory. When re-tested in March 2014, all remained positive for HIV-1 antibody. In 67 samples, titres remained unchanged, there was one dilution decrease in 1 sample, and an increase between 1 and 5 dilutions in 30 samples; the latter changes may be due to variations in testing conditions. In conclusion, these findings suggest that, over long periods, HIV-1 antibody concentration does not deteriorate in DBS samples stored at 4 and −20°C, or in eluates stored at −20°C. This implies that archived DBS samples could be reliably used in retrospective studies on HIV and potentially other infections. Acknowledgements We are grateful to the Laboratory Quality Assurance and Standardization Programs, Division of Laboratory Sciences, CDC for providing the quality assurance and quality control specimens used in this letter. D.W. curated the samples and carried out the testing. All authors contributed to the final draft and approved it. We are grateful to the Health Protection Agency (now Public Health England), and to the Welton Foundation for additional funding. The UCL Institute of Child Health receives a proportion of funding from the Department of Health's National Institute for Health Research Biomedical Research Centres funding scheme. Conflicts of interest There are no conflicts of interest.
Read more