Minimize Low-Order Harmonics in Low-Switching-Frequency Space-Vector-Modulated Current Source Converters With Minimum Harmonic Tracking Technique
- Apr 01, 2009
- IEEE Transactions on Power Electronics
- M.F Naguib + 1 more +1
Gate turnoffs (GTOs) are usually used in high-power current source converters (CSCs), i.e., rectifiers and inverters. Space vector modulation (SVM) technique for CSC is established by dividing ac-side line current cycle into six sectors. Each sector is divided into a certain number of SV cycles. SV cycle is divided into three states: two active and one zero state. For low switching frequency as required by GTOs, the SVM technique generates fifth and seventh harmonics (HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> ) in the CSC ac-side current. Minimal reduction in HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> was achieved with certain states sequence inside the SV cycle. Moderate reduction in HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> was obtained by calculating states on -times at once in the middle of each SV cycle. In this paper, larger reduction in HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> at CSC ac-side current is achieved by new techniques for calculating states on-times. First, two straightforward techniques are proposed. One calculates states on-times from SVM equations in the middle of each state on-time. The other calculates all states on -times when the state changes from one active state to the other. Both techniques are effective in reducing HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> . Then, minimum harmonics tracking (MHT) technique for calculating states on-times in SVM CSC is proposed. Tracking technique adjusts states on-times once per four ac-side line current cycles to give the least HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> . In CSC with a large overlap period, power factor affects HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> , so two-variables MHT technique for both active states on-times inside SV cycle is proposed to give the least HD <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5-7</sub> . Also, a variable perturbation tracking technique is proposed to reduce transient time with unperturbed steady-state operation. Finally, experimental investigations and obstacles are introduced.
Read more