• Home
  • Search
  • A correction algorithm to simultaneously control dual deformable mirrors in a woofer-tweeter adaptive optics system
  • Cite Icon45
  • https://doi.org/10.1364/oe.18.016671Copy DOI Icon

A correction algorithm to simultaneously control dual deformable mirrors in a woofer-tweeter adaptive optics system

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

We present a direct slope-based correction algorithm to simultaneously control two deformable mirrors (DMs) in a woofer-tweeter adaptive optics system. A global response matrix was derived from the response matrices of each deformable mirror and the voltages for both deformable mirrors were calculated simultaneously. This control algorithm was tested and compared with a 2-step sequential control method in five normal human eyes using an adaptive optics scanning laser ophthalmoscope. The mean residual total root-mean-square (RMS) wavefront errors across subjects after adaptive optics (AO) correction were 0.128 ± 0.025 μm and 0.107 ± 0.033 μm for simultaneous and 2-step control, respectively (7.75-mm pupil). The mean intensity of reflectance images acquired after AO convergence was slightly higher for 2-step control. Radially-averaged power spectra calculated from registered reflectance images were nearly identical for all subjects using simultaneous or 2-step control. The correction performance of our new simultaneous dual DM control algorithm is comparable to 2-step control, but is more efficient. This method can be applied to any woofer-tweeter AO system.

Similar Papers
  • Research Article
  • Citations8

Miniature eye movements measured simultaneously with ophthalmic imaging and a dual-Purkinje image eye tracker

  • Mar 17, 2010
  • Journal of Vision
  • S B Stevenson +1
  • Research Article
  • Citations57

High-Resolution Imaging of Retinal Nerve Fiber Bundles in Glaucoma Using Adaptive Optics Scanning Laser Ophthalmoscopy

  • Jan 23, 2013
  • American Journal of Ophthalmology
  • Kohei Takayama +10
  • Conference Article
  • Citations9

Effect of adaptive optical system on the capability of lidar detection in atmosphere

  • May 11, 2009
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Xue-Chun Tan +2
  • Research Article
  • Citations5

Testing for a slope-based decoupling algorithm in a woofer-tweeter adaptive optics system.

  • Apr 23, 2018
  • Applied Optics
  • Tao Cheng +5
  • Conference Article
  • Citations2

HIGH RESOLUTION WAVEFRONT CONTROL OF HIGH-POWER LASER SYSTEMS

  • Dec 01, 1999
  • Michael W Kartz +7
  • Research Article
  • Citations37

Dysflective cones: Visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis

  • Apr 12, 2017
  • American journal of ophthalmology case reports
  • Joanna H Tu +9
  • Research Article
  • Citations43

Lifecycles of Individual Subretinal Drusenoid Deposits and Evolution of Outer Retinal Atrophy in Age-Related Macular Degeneration

  • Oct 31, 2019
  • Ophthalmology. Retina
  • Yuhua Zhang +7
  • Research Article
  • Citations21

Spontaneous remission of acute zonal occult outer retinopathy: follow-up using adaptive optics scanning laser ophthalmoscopy.

  • Aug 02, 2014
  • Graefe's Archive for Clinical and Experimental Ophthalmology
  • Shintaro Nakao +4
  • PDF
  • Research Article
  • Citations29

A demonstration of wavefront sensing and mirror phasing from the image domain

  • Mar 08, 2014
  • Monthly Notices of the Royal Astronomical Society
  • Benjamin Pope +5
  • Conference Article
  • Citations23

Characterizing the potential of MEMS deformable mirrors for astronomical adaptive optics

  • Jun 14, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Katie M Morzinski +7
  • Conference Article

First-order performance evaluation of adaptive optics systems for turbulence compensation in extended field-of-view astronomical telescopes

  • Jan 01, 1992
  • Brent L Ellerbroek
  • Research Article
  • Citations140

High-Resolution Imaging of Resolved Central Serous Chorioretinopathy Using Adaptive Optics Scanning Laser Ophthalmoscopy

  • Jul 29, 2010
  • Ophthalmology
  • Sotaro Ooto +10
  • Supplementary Content
  • Citations1

Adaptive Optics Imaging in Diabetic Retinopathy: A Comprehensive Review

  • Jan 01, 2025
  • Romanian Journal of Ophthalmology
  • Andrada-Elena Mirescu +6
  • Research Article
  • Citations32

Distances From Capillaries to Arterioles or Venules Measured Using OCTA and AOSLO

  • May 01, 2019
  • Investigative Ophthalmology & Visual Science
  • Edmund Arthur +5
  • Single Report
  • Citations3

Initial Demonstration of Mercury Wavefront Correction System

  • Feb 01, 2006
  • Z Liao
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.