• Home
  • Search
  • A dynamic reconstruction and motion estimation framework for cardiorespiratory motion-resolved real-time volumetric MR imaging (DREME-MR)
  • Cite Icon1
  • https://doi.org/10.1088/1361-6560/adf9b9Copy DOI Icon

A dynamic reconstruction and motion estimation framework for cardiorespiratory motion-resolved real-time volumetric MR imaging (DREME-MR)

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Based on a 3D pre-treatment magnetic resonance (MR) scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and solve a data-driven, patient-specific cardiorespiratory motion model. Via a motion encoder simultaneously learned during the reconstruction, DREME-MR further enables real-time volumetric MR imaging and cardiorespiratory motion tracking with minimal intra-treatment k-space data.&#xD;&#xD;Approach: DREME-MR integrates dynamic MRI reconstruction and real-time MR imaging into a unified, dual-task learning framework. From a 3D radial-spoke-based pre-treatment MR scan, DREME-MR uses spatiotemporal implicit-neural-representation (INR) to reconstruct pre-treatment dynamic volumetric MR images (learning task 1). The INR-based reconstruction takes a joint image reconstruction and deformable registration approach, yielding a reference anatomy and a corresponding cardiorespiratory motion model. The motion model adopts a low-rank, multi-resolution representation to approximate motion fields as products of motion coefficients and motion basis components (MBCs). Via a progressive, frequency-guided strategy, DREME-MR decouples cardiac MBCs from respiratory MBCs to resolve the two distinct motion modes. Simultaneously with the pre-treatment dynamic MRI reconstruction, DREME-MR also trains a multilayer perceptron (MLP)-based motion encoder to infer cardiorespiratory motion coefficients directly from the raw k-space data (learning task 2), allowing real-time, intra-treatment volumetric MR imaging and motion tracking with minimal k-space data (20-30 spokes) acquired after the pre-treatment MRI scan.&#xD;&#xD;Main results: Evaluated using data from a digital phantom (XCAT) and a human scan, DREME-MR solves real-time 3D cardiorespiratory motion with a latency of < 165 ms (= 150-ms data acquisition + 15-ms inference time), fulfilling the temporal constraint of real-time imaging. The XCAT study achieves mean(±S.D.) center-of-mass tracking errors of 0.73±0.38mm for a lung tumor and 1.69±1.12mm for the left ventricle. The human study shows good motion correlations (liver: 0.96; left ventricle: 0.65) between DREME-MR-solved motion and extracted surrogate signals.&#xD;&#xD;Significance: DREME-MR allows real-time 3D MRI and cardiorespiratory motion tracking with low latency, advancing intra-treatment MR-guided adaptive radiotherapy, including real-time multileaf collimator (MLC) tracking.

Similar Papers
  • Research Article
  • Citations63

Real‐time flow MRI of the aorta at a resolution of 40 msec

  • Oct 11, 2013
  • Journal of Magnetic Resonance Imaging
  • Arun Joseph +8
  • Research Article
  • Citations49

Real-time Magnetic Resonance Imaging Aids Prenatal Diagnosis of Isolated Cleft Palate

  • Nov 01, 2005
  • Journal of Ultrasound in Medicine
  • Joao Fernando Kazan-Tannus +7
  • Research Article
  • Citations25

New-Generation Laser-lithographed Dual-Axis Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Multiplanar Navigation at 1.5 T and 3 T versus X-ray Fluoroscopy.

  • Jun 01, 2015
  • Radiology
  • Parham Moftakhar +9
  • PDF
  • Research Article
  • Citations66

Technical Challenges of Real-Time Adaptive MR-Guided Radiotherapy.

  • Mar 08, 2021
  • Frontiers in Oncology
  • Daniela Thorwarth +1
  • Research Article
  • Citations8

Characteristics of articulatory gestures in stuttered speech: A case study using real-time magnetic resonance imaging

  • Mar 18, 2022
  • Journal of Communication Disorders
  • Yijing Lu +4
  • PDF
  • Research Article
  • Citations67

Real-Time Visualization of Joint Cavitation

  • Apr 15, 2015
  • PLoS ONE
  • Gregory N Kawchuk +5
  • Research Article
  • Citations18

Utility of Real-Time 3-Dimensional Echocardiography and Magnetic Resonance Imaging for Evaluation of Danon Disease

  • May 03, 2010
  • Circulation
  • Hiroshi Tada +7
  • Conference Article
  • Citations13

Statistical multi-stream modeling of real-time MRI articulatory speech data

  • Sep 26, 2010
  • Erik Bresch +3
  • Research Article
  • Citations52

Randomized, Sham-Controlled Trial of Real-Time Functional Magnetic Resonance Imaging Neurofeedback for Tics in Adolescents With Tourette Syndrome

  • Aug 13, 2019
  • Biological Psychiatry
  • Denis G Sukhodolsky +12
  • Research Article
  • Citations33

Feasibility of Stent Placement in Carotid Arteries with Real-time MR Imaging Guidance in Pigs

  • Dec 10, 2004
  • Radiology
  • Lei Feng +6
  • Research Article
  • Citations4

Measuring three-dimensional tibiofemoral kinematics using dual-slice real-time magnetic resonance imaging.

  • Aug 29, 2019
  • Medical physics
  • Cheng‐Chung Lin +5
  • Research Article
  • Citations25

Quantification of Left Ventricular Function With Premature Ventricular Complexes Reveals Variable Hemodynamics.

  • Apr 01, 2016
  • Circulation: Arrhythmia and Electrophysiology
  • Francisco Contijoch +12
  • Research Article
  • Citations24

Test-retest repeatability of human speech biomarkers from static and real-time dynamic magnetic resonance imaging.

  • May 01, 2017
  • The Journal of the Acoustical Society of America
  • Johannes Töger +6
  • Research Article
  • Citations16

Real-time Magnetic Resonance–guided Placement of Retrievable Inferior Vena Cava Filters: Comparison with Fluoroscopic Guidance with Use of In Vitro and Animal Models

  • Feb 01, 2006
  • Journal of Vascular and Interventional Radiology
  • Ming-Chen Paul Shih +2
  • Research Article
  • Citations107

Recommendations for real-time speech MRI.

  • Jul 14, 2015
  • Journal of magnetic resonance imaging : JMRI
  • Sajan Goud Lingala +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.