• Home
  • Search
  • A framework for defining FLASH dose rate for pencil beam scanning
  • Open Access IconOpen Access
  • Cite Icon170
  • https://doi.org/10.1002/mp.14456Copy DOI Icon

A framework for defining FLASH dose rate for pencil beam scanning

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

PurposeTo develop a method of (a) calculating the dose rate of voxels within a proton field delivered using pencil beam scanning (PBS), and (b) reporting a representative dose rate for the PBS treatment field that enables correspondence between multiple treatment modalities. This method takes into account the unique spatiotemporal delivery patterns of PBS FLASH radiotherapy.MethodsThe dose rate at each voxel of a PBS radiation field is approximately the quotient of the voxel’s dose and “effective” irradiation time. Each voxel’s “effective” irradiation time starts when the cumulative dose rises above a chosen threshold value, and stops when its cumulative dose reaches its total dose minus the same threshold value. The above calculation yields a distribution of dose rates for the voxels within a PBS treatment field. To report a representative dose rate for the PBS field, we propose a user‐selectable parameter of pth percentile of the dose rate distribution, such that (100 − p) % of the field is above the corresponding dose rate. To demonstrate the method described above, we design FLASH transmission fields using 250 MeV protons and calculate the PBS dose rate distributions in both two‐dimensional (2D) and three‐dimensional (3D) models. To further evaluate the formalism, we provide an example of a clinical PBS treatment field.ResultsWith the 2D PBS transmission field, it is demonstrated that the time to accumulate the total dose at a voxel is limited to a fraction of the delivery time of the entire field. In addition, the spatial distributions of dose and dose rate are quite different within the field. For the 10 × 10 cm2 PBS field irradiating a 3D water phantom, the prescribed dose of 10 Gy at 10 cm depth is delivered in 1.0 s. The dose rate decreases in the irradiated volume with increasing depth (until the Bragg peak) due to increase of beam spot size by Coulomb scattering. For example, 95% of the irradiated volume between 0 and 10 cm depth receive >40 Gy/s, whereas between 0–20 cm and 0–30 cm depth, 95% of the irradiated volume received >36 Gy/s and >24 Gy/s, respectively. For the clinical PBS treatment field, the scanning pattern conforms to the PTV. PBS dose rate data are presented for the PTV and adjacent normal organs.ConclusionWe have developed a method of calculating the dose rate distribution of a PBS proton field and have recommended nomenclature for reporting PBS treatment dose rate. We believe that standardizing the method for calculating and reporting PBS treatment dose rates, in a manner that corresponds with other treatment modalities, will advance the research and potential application of PBS FLASH radiotherapy.

Similar Papers
  • Research Article
  • Citations4

Patient-specific quality assurance of dynamically-collimated proton therapy treatment plans.

  • Jul 08, 2024
  • Medical physics
  • Laura C Bennett +16
  • Research Article
  • Citations1

Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures.

  • Dec 01, 2025
  • Medical physics
  • Per Rugaard Poulsen +3
  • Research Article
  • Citations28

Definition of dose rate for FLASH pencil-beam scanning proton therapy: A comparative study.

  • Jul 13, 2023
  • Medical Physics
  • Sylvain Deffet +2
  • PDF
  • Research Article
  • Citations3

Ion therapy guideline (Version 2020)

  • Jun 01, 2021
  • Precision Radiation Oncology
  • Qiuning Zhang +3
  • Research Article
  • Citations4

The dependence of interplay effects on the field scan direction in PBS proton therapy

  • Apr 23, 2019
  • Physics in Medicine & Biology
  • G Fattori +9
  • Research Article

SU‐E‐T‐567: Neutron Dose Equivalent Evaluation for Pencil Beam Scanning Proton Therapy with Apertures

  • Jun 01, 2015
  • Medical Physics
  • C Geng +3
  • Research Article
  • Citations2

Radiation-Induced Acute Lung Pneumonitis After Pencil-Beam Scanning Proton Treatment for Breast Cancer: Correlation With Dose-Volume Parameters and Optimization Objectives to Reduce Lung Toxicities.

  • Feb 01, 2026
  • Practical radiation oncology
  • Jiyeon Park +10
  • Research Article
  • Citations1

SU‐E‐CAMPUS‐T‐06: Initial Experience of Patient‐Specific QA Using a Pencil Beam Scanning Proton Therapy System

  • May 29, 2014
  • Medical Physics
  • F Piskulich +6
  • Abstract
  • Citations1

A Potential Cause for Unexplained Radiation Toxicity in Proton Therapy

  • Sep 29, 2023
  • International Journal of Radiation Oncology*Biology*Physics
  • J Daartz +4
  • Research Article
  • Citations53

Reassessment of the Necessity of the Proton Gantry: Analysis of Beam Orientations From 4332 Treatments at the Massachusetts General Hospital Proton Center Over the Past 10 Years

  • Sep 30, 2015
  • International Journal of Radiation Oncology*Biology*Physics
  • Susu Yan +5
  • Research Article
  • Citations1

Deliverable proton conformal FLASH radiotherapy treatment planning for head and neck re-irradiation patients.

  • Mar 01, 2026
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
  • Wei Zou +19
  • Research Article

SU‐E‐T‐695: Silicon Diode Measurements of Output Field Size Factors for Proton Pencil Beam Scanning with a Dedicated Nozzle

  • Jun 01, 2015
  • Medical Physics
  • J Mcglade +2
  • Research Article
  • Citations45

Assessing the quality of proton PBS treatment delivery using machine log files: comprehensive analysis of clinical treatments delivered at PSI Gantry 2

  • Jan 15, 2016
  • Physics in Medicine & Biology
  • D Scandurra +6
  • Research Article

SU‐E‐T‐659: Maximizing the Therapeutic Effect of a Fractionated Treatment with Delivery of Inhomogeneous Daily Dose Distributions

  • Jun 01, 2011
  • Medical Physics
  • A Trofimov +2
  • Research Article
  • Citations3

Quantitative beta autoradiography of a heterogeneous granulite sample and implications for luminescence dating

  • Sep 02, 2023
  • Radiation Measurements
  • L Martin +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.