Abstract

This paper introduces a single-phase voltage source current-controlled pulse width modulation rectifier model, acting as an active power filter (APF), with a fuzzy logic controller in the inner loop and a simple proportional-integral (PI) d.c. link voltage controller in the outer loop to compensate reactive power and current harmonic components simultaneously from nonlinear loads. The proposed scheme operates with a fixed switching frequency. The control scheme of the APF is simple, since it has fewer control inputs for determining the desired action. It is easily tunable for different performance criteria and can be achieved by means of low-cost of hardware installation, as it does not need to use more sensitive and accurate measuring devices. The model can also compensate both reactive and harmonic current components from nonlinear loads.

Similar Papers
  • Research Article
  • Citations188

Neural Network-Based Selective Compensation of Current Quality Problems in Distribution System

  • Feb 01, 2007
  • IEEE Transactions on Industrial Electronics
  • Bhim Singh +2
  • Research Article
  • Citations49

Real time implementation of PI and fuzzy logic controller based 3-phase 4-wire interleaved buck active power filter for mitigation of harmonics with id–iq control strategy

  • Mar 03, 2014
  • International Journal of Electrical Power & Energy Systems
  • Ranjeeta Patel +1
  • Book Chapter
  • Citations7

41 - Active Filters

  • Jan 01, 2011
  • POWER ELECTRONICS HANDBOOK
  • Luis Morán +1
  • Conference Article

Application of eigen- decomposition of signals to harmonic noise detection and cancellation, in electric power systems

  • Nov 01, 2008
  • Shahira M El-Fiki +2
  • Conference Article
  • Citations11

Performance Comparison of Sampled Hysteresis and Predictive Control Methods for Tracking Current in APF

  • Dec 10, 2020
  • Sandeep Ojha +1
  • Research Article
  • Citations6

Predictive current control of FL-shunt active power filter for dynamic and heterogeneous load compensation

  • Feb 03, 2021
  • Electrical Engineering
  • Dheepanchakkravarthy Azhagesan +4
  • Conference Article
  • Citations7

Sliding DFT assisted instantaneous symmetrical components method for estimating reference current to Active Power Filter

  • Aug 01, 2012
  • S Chandrasekaran +1
  • Research Article
  • Citations6

Switching‐loss reduction technique in active power filters without auxiliary circuits

  • Mar 01, 2016
  • IET Power Electronics
  • Chi‐Seng Lam +5
  • Conference Article
  • Citations29

Power quality considerations on shunt/series current and voltage conditioners

  • Oct 06, 2002
  • E.H Watanabe +1
  • Research Article
  • Citations43

Meeting IEEE-519 Current Harmonics and Power Factor Constraints With a Three-Phase Three-Wire Active Power Filter Under Distorted Source Voltages

  • Jul 01, 2006
  • IEEE Transactions on Power Delivery
  • G.W Chang +2
  • Conference Article
  • Citations67

A series active power filter which compensates current harmonics and voltage unbalance simultaneously

  • Jun 18, 1995
  • L Moran +3
  • Conference Article

Unified Power Quality Conditioner for three phase four wire distribution system

  • Mar 01, 2015
  • Monika Deshpande +1
  • Conference Article
  • Citations4

Single-phase shunt active power filter with novel harmonic detection

  • Oct 22, 2001
  • M Rukonuzzaman +1
  • Conference Article
  • Citations12

A Flexible Compensation Strategy for Weak Grid-Tied Current Controlled Converters Under Unbalanced and Harmonic Conditions

  • Dec 16, 2020
  • Suresh Maganti +1
  • Conference Article
  • Citations1

Series hybrid power filter based on SVPWM-VSI to compensate for source current harmonics and voltage unbalance

  • Dec 01, 2009
  • Yushaizad Yusof +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.