• Home
  • Search
  • A Minibatch Alternating Projections Algorithm for Robust and Efficient Magnitude Least-Squares RF Pulse Design in MRI.
  • Cite Icon2
  • https://doi.org/10.1109/tmi.2024.3515035Copy DOI Icon

A Minibatch Alternating Projections Algorithm for Robust and Efficient Magnitude Least-Squares RF Pulse Design in MRI.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A magnitude-least-squares radiofrequency pulse design algorithm is reported which uses interleaved exact and stochastically-generated inexact updates to escape local minima and find low-cost solutions. Inexact updates are performed using a small randomly selected minibatch of the available measurements to update RF pulse weights, which perturbs the sequence of alternating projections. Applications to RF shimming, parallel transmit spokes RF pulse design, and spectral-spatial RF pulse design are considered. Numerical and simulation studies characterized the optimal minibatch size, which was found to consistently produce lower power and lower RMSE solutions across subjects, coil geometries, resolutions and orientations. The method was validated in-vivo at 7 Tesla and produced improvements in image quality in a slice-by-slice RF-shimmed imaging sequence. Compared to conventional methods, the pulse design method can more robustly design RF pulses that correct for inhomogeneities at ultra-high field strengths, and enable pulse designs to be completed with increased computational efficiency.

Similar Papers
  • Research Article
  • Citations15

Multiband RF pulse design for realistic gradient performance

  • Sep 14, 2018
  • Magnetic Resonance in Medicine
  • Samy Abo Seada +4
  • Research Article
  • Citations58

Additive angle method for fast large‐tip‐angle RF pulse design in parallel excitation

  • Mar 27, 2008
  • Magnetic Resonance in Medicine
  • William A Grissom +4
  • Research Article
  • Citations29

Ultrafast (milliseconds), multidimensional RF pulse design with deep learning

  • Mar 30, 2019
  • Magnetic Resonance in Medicine
  • Mads Sloth Vinding +3
  • Research Article

SU-F-303-06: Effect of Multiband RF Pulse Duration On Cine MRI Tracking Accuracy for MRI-GRT

  • Jun 01, 2015
  • Medical Physics
  • N Mickevicius +3
  • Research Article

B1 inhomogeneity effect reduction for 2D spatial selective RF pulse using simulated annealing

  • Apr 01, 2008
  • Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering
  • Yong Pang +1
  • Research Article
  • Citations38

Equi-ripple design of quadratic-phase RF pulses

  • Nov 19, 2003
  • Journal of Magnetic Resonance
  • Rolf F Schulte +3
  • Research Article

Large gains in SNR through the application of Shinnar-Le Roux RF pulse design to short-TR spin-echo fMRI acquisitions at 7T.

  • Jun 01, 2026
  • Magnetic resonance imaging
  • Mukund Balasubramanian +3
  • Research Article
  • Citations10

Feasibility of High-Dose Dobutamine Stress SSFP Cine MRI at 3 Tesla with Patient Adaptive Local RF Shimming using Dual-Source RF Transmission: Initial Results

  • Nov 05, 2012
  • RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
  • Katharina Strach +8
  • Research Article
  • Citations20

Improving excitation and inversion accuracy by optimized RF pulse using genetic algorithm

  • Jan 30, 2007
  • Journal of Magnetic Resonance
  • Yong Pang +1
  • Research Article
  • Citations21

Simultaneous multislice refocusing via time optimal control.

  • Feb 09, 2018
  • Magnetic Resonance in Medicine
  • Armin Rund +3
  • Supplementary Content

Design of calibration-free RF pulses for T2-weighted single-slab 3D turbospin-echo sequences at 7T utilizing parallel transmission

  • Feb 28, 2023
  • Zenodo (CERN European Organization for Nuclear Research)
  • Daniel Löwen +6
  • Research Article
  • Citations13

Approaching ultimate intrinsic specific absorption rate in radiofrequency shimming using high-permittivity materials at 7 Tesla.

  • Nov 28, 2017
  • Magnetic resonance in medicine
  • Gillian G Haemer +5
  • Research Article

116 IMAGE QUALITY AND RADIATION DOSE WITH SINGLE HEART BEAT 320 MULTIDETECTOR CT CORONARY ANGIOGRAPHY

  • May 01, 2013
  • Heart
  • M C Williams +9
  • Research Article

The role of AI in optimizing CMR image quality: A scoping review.

  • Jan 01, 2026
  • Journal of medical imaging and radiation sciences
  • Daniele Silipo +2
  • Conference Article

Trace Inversion Applied for Porosity Estimation in Deep Targets, Algeria

  • Jan 01, 2020
  • L De Vincenzi +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.