• Home
  • Search
  • A Multi-Segments Stitching Method for Profile Measurement of Large Scale Aspheric Surface within Submicrometer Accuracy
  • Cite Icon1
  • https://doi.org/10.4028/www.scientific.net/amm.870.95Copy DOI Icon

A Multi-Segments Stitching Method for Profile Measurement of Large Scale Aspheric Surface within Submicrometer Accuracy

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A multi-segments stitching method is proposed to obtain two-dimensional profile of large scale aspheric components during grinding process. We firstly analyze the corresponding relation between surface features of aspherics and measurement range of profilometer. According to multi-body system theory and slope difference, a mathematical model of multi-segments stitching method is constructed. Further, the multi-segments stitching errors based on 400 mm aspheric profile are simulated with different translation amounts, rotation angles, translation errors as well as rotation errors. The simulation results indicate that the translation error is the key factor for measuring accuracy of the multi-segments stitching method. In addition, the standard deviations of multi-segments stitching errors are between 0.2 μm and 0.4 μm as the four factors are set to the proper values. To verify the simulation analysis results, an experimental setup, including Talysurf PGI 1240 and fixture, is applied to detect a 150 mm profile line on the aspheric surface. The experiment results show that the standard deviations of multi-segments stitching errors are almost within 1 μm when the rotation angle is under 7° and the translation amount is under 11 mm. The multi-segments stitching method can employ a small-range profilometer to achieve measurement of large scale aspheric surfaces with submicrometer accuracy.

Similar Papers
  • Research Article
  • Citations4

Study on error analysis and accuracy improvement for aspheric profile measurement

  • Apr 11, 2017
  • Measurement Science and Technology
  • Huimin Gao +2
  • Research Article

Improved 2D image registration algorithm applied to head and neck tumor

  • Sep 25, 2017
  • Zhonghua fangshe yixue yu fanghu zazhi
  • Cheng Chen +2
  • Conference Article
  • Citations1

Minimization of tool tracking error using fulcrum correction in minimally invasive interventions: application to prostate biopsy procedure

  • Mar 02, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Derek Cool +4
  • Research Article

SU-E-T-553: Evaluation of Rotational Errors in Treatment Setup of Stereotactic Body Radiotherapy (SBRT) of Lung Cancer

  • Jun 01, 2011
  • Medical Physics
  • M Cao +4
  • Conference Article
  • Citations6

The confounding of translation and rotation in reconstruction from multiple views

  • Jun 17, 1997
  • C Fermuller +1
  • Research Article
  • Citations56

Ambiguity in Structure from Motion: Sphere versus Plane

  • Jun 01, 1998
  • International Journal of Computer Vision
  • Cornelia Fermüller +1
  • Research Article
  • Citations22

Profile measurement of aspheric surfaces using scanning deflectometry and rotating autocollimator with wide measuring range

  • Apr 30, 2014
  • Measurement Science and Technology
  • Kyohei Ishikawa +4
  • Research Article
  • Citations2

Mask dependency of the lacrimal gland dose under whole brain radiotherapy when the six‐degrees of freedom couch is not available

  • May 31, 2023
  • Journal of Applied Clinical Medical Physics
  • Jai‐Woong Yoon +6
  • Research Article
  • Citations9

Aspheric surface measurement by absolute wavelength scanning interferometry with model-based retrace error correction.

  • Mar 30, 2023
  • Optics Express
  • Marek Stašík +5
  • Research Article
  • Citations15

Measurement of aspheric surface combining point diffraction interferometry and annular subaperture stitching

  • Jan 02, 2015
  • Optical Engineering
  • Fen Gao +3
  • Research Article
  • Citations1

Evaluation of the dosimetric influence of interfractional 6D setup error in hypofractionated prostate cancer treated with IMRT and VMAT using daily kV-CBCT

  • Oct 23, 2022
  • Journal of Medical Imaging and Radiation Sciences
  • Prashantkumar Shinde +3
  • Research Article
  • Citations21

Patient positioning verification for proton therapy using proton radiography

  • Dec 01, 2018
  • Physics in Medicine & Biology
  • A Hammi +4
  • Research Article

SU‐E‐T‐333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans

  • Jun 01, 2015
  • Medical Physics
  • S Rana +1
  • Conference Article

White-light interferometric measurement of spherical and aspherical surfaces

  • Nov 06, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Suping Chang +1
  • Research Article
  • Citations13

Technical Note: Rotational positional error corrected intrafraction set-up margins in stereotactic radiotherapy: A spatial assessment for coplanar and noncoplanar geometry.

  • Oct 01, 2019
  • Medical Physics
  • Biplab Sarkar +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.