• Home
  • Search
  • A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction.
  • Cite Icon7
  • https://doi.org/10.1118/1.4905162Copy DOI Icon

A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy-Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy-Richardson deconvolution algorithm to the current estimation of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. This study demonstrates the feasibility of incorporating the Lucy-Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.

Similar Papers
  • Research Article
  • Citations39

Performance measurement of PSF modeling reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT

  • Feb 07, 2014
  • Annals of Nuclear Medicine
  • Young Sub Lee +5
  • Research Article
  • Citations37

Relative role of motion and PSF compensation in whole‐body oncologic PET‐MR imaging

  • Mar 24, 2014
  • Medical Physics
  • Yoann Petibon +7
  • Conference Article
  • Citations2

Scan time reduction with advanced PET reconstruction: Preserving lesion detection performance

  • Oct 01, 2010
  • D J Kadrmas +3
  • Research Article
  • Citations41

Effect of Scan Time on Oncologic Lesion Detection in Whole-Body PET

  • Oct 01, 2012
  • IEEE Transactions on Nuclear Science
  • D J Kadrmas +3
  • Research Article
  • Citations3

Enhancing obSTORM imaging performance with cubic spline PSF modeling.

  • Sep 07, 2023
  • Biomedical Optics Express
  • Donghoon Koo +3
  • Research Article
  • Citations2

Galaxy–point spread function correlations as a probe of weak-lensing systematics with UNIONS data

  • Aug 01, 2025
  • Astronomy & Astrophysics
  • Sacha Guerrini +8
  • Book Chapter
  • Citations1

Long Exposure Point Spread Function Modeling with Gaussian Processes

  • Jan 01, 2016
  • Ping Guo +2
  • Research Article
  • Citations9

Optical-aberrations-corrected light field re-projection for high-quality plenoptic imaging.

  • Jan 22, 2020
  • Optics Express
  • Yanqin Chen +2
  • Conference Article

Depth-map based on single-passive sensor

  • Jan 01, 2016
  • Jongho Choi +1
  • PDF
  • Research Article
  • Citations66

Impact of a Bayesian penalized likelihood reconstruction algorithm on image quality in novel digital PET/CT: clinical implications for the assessment of lung tumors

  • Sep 26, 2018
  • EJNMMI Physics
  • Michael Messerli +8
  • PDF
  • Research Article
  • Citations42

The association of tumor-to-background ratios and SUVmax deviations related to point spread function and time-of-flight F18-FDG-PET/CT reconstruction in colorectal liver metastases.

  • May 06, 2015
  • EJNMMI Research
  • Julian Mm Rogasch +9
  • Research Article

Role of Lesion-to-Background Activity Ratio and Background Activity in Optimization of Reconstruction Protocols for FDG PET/CT Images of Overweight Patients: A Phantom Study

  • Feb 10, 2023
  • Innovative Journal of Radiology
  • Samira Rezvani +3
  • Research Article
  • Citations1

Quantification of FDG in the spinal cord using PET/MRI

  • Aug 26, 2025
  • Frontiers in Nuclear Medicine
  • Eve Lennie +4
  • PDF
  • Research Article
  • Citations15

Silicon-photomultiplier-based PET/CT reduces the minimum detectable activity of iodine-124

  • Sep 01, 2021
  • Scientific Reports
  • David Kersting +11
  • Research Article
  • Citations3

Evaluation of Image Reconstruction Techniques in Single Photon Emission Computed Tomography (SPECT/CT) Imaging

  • Apr 20, 2018
  • Research & Reviews: Journal of Physics
  • F Usman +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.