• Home
  • Search
  • A practical criterion for focusing of unstained cell samples using a digital holographic microscope.
  • Cite Icon9
  • https://doi.org/10.1111/jmi.12924Copy DOI Icon

A practical criterion for focusing of unstained cell samples using a digital holographic microscope.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Digital holographic microscopy (DHM) is an important technique that may be used for quantitative phase imaging of unstained biological cell samples. Since the DHM technology is not commonly used in clinics or bioscience research labs, at present there is no well-accepted focusing criterion for unstained samples that users can follow while recording image plane digital holograms of cells. The usual sharpness metrics that are useful for auto-focusing of stained cells do not work well for unstained cells as there is no amplitude contrast. In this work, we report a practical method for estimating the best focus plane for unstained cells in the digital hologram domain. The method is based on an interesting observation that for the best focus plane the fringe pattern associated with individual unstained cells predominantly shows phase modulation effect in the form of bending of fringes and minimal amplitude modulation. This criterion when applied to unstained red blood cells shows that the central dip in the doughnut-like phase profile of cells is maximal in this plane. The proposed methodology is helpful for standardizing the usage of DHM technology across different users and application developmentefforts. LAY DESCRIPTION: Digital holographic microscopy (DHM) is slowly but steadily becoming an important microscopy modality and gaining acceptability for basic bio-science research as well as clinical usage. One of the important features of DHM is that it allows users to perform quantitative imaging of unstained transparent cells. Instead of using dyes or fluorescent labelling, DHM systems use quantitative phase as a contrast mechanism which depends on the natural refractive index variation within the cell samples. Since minimal wet lab processing is required in order to image cell samples with a DHM, cells can be imaged in their natural state. While DHM is gaining popularity among users, the imaging protocols across the labs or users need to be standardized in order to make sure that the same quantitative phase parameters are used for tasks such as quantitative phased based cellclassification. One of the important operational tasks for any microscopy work is to focus the sample under study. While focusing comes naturally to users of brightfield microscopes based on image contrast, the focusing is not straightforward when samples are unstained so that they do not offer any amplitude contrast. When performing quantitative phase imaging, defocus can actually change the phase profile of the cell due to near-zone (Fresnel) diffraction effects. So unless a standardized focusing methodology is used, it will be difficult for multiple DHM users (potentially at different sites) to agree on quantitative results out of their phase images. DHM literature has prior works which perform numerical focusing of recovered complex wave-field in the hologram plane to find the best focus plane. However such methods are not user friendly and do not allow user the same focusing experience as in a brightfield microscope. The numerical focusing is therefore a reasonably good method for an optics researcher but not necessarily so for a microscopy technician looking at cell samples with a DHM system in a clinicalsetting. The present work provides a simple focusing criterion for unstained samples that works directly in the hologram domain. The technique is based on an interesting observation that the when an unstained cell sample is in the best-focus plane, its corresponding hologram (or fringe pattern) predominantly shows phase modulation manifested by bending of fringes at the location of the cell. This criterion can be converted into a simple numerical method as we have used to find the best-focus plane using a stack of through focus holograms. We believe that the technique can be used manually by visually observing the holograms or can be converted to an auto-focus algorithm for a motorized DHMsystem.

Similar Papers
  • Research Article
  • Citations40

Quantitative phase microscopy for evaluation of intestinal inflammation and wound healing utilizing label-free biophysical markers.

  • Oct 09, 2017
  • Histology and histopathology
  • Dominik Bettenworth +6
  • Research Article
  • Citations57

Simple and flexible phase compensation for digital holographic microscopy with electrically tunable lens.

  • Jul 19, 2017
  • Applied Optics
  • Dingnan Deng +6
  • Discussion
  • Citations6

Moving into a new dimension: Tracking migrating cells with digital holographic cytometry in 3D.

  • Dec 16, 2018
  • Cytometry Part A
  • Anette Gjörloff Wingren
  • Conference Article

Quantitative single-shot phase imaging with a dielectric metasurface

  • Apr 18, 2021
  • Einstom Engay +4
  • PDF
  • Research Article
  • Citations35

Quantitative Phase Imaging Using Digital Holographic Microscopy Reliably Assesses Morphology and Reflects Elastic Properties of Fibrotic Intestinal Tissue

  • Dec 01, 2019
  • Scientific Reports
  • Arne Bokemeyer +10
  • Conference Article

Nanocapsule induced morphology and migration changes in single cell layers quantified with digital holographic microscopy

  • Mar 04, 2019
  • Mathias Kaiser +8
  • Conference Article
  • Citations2

Quantitative phase imaging-based machine learning approaches for the analysis of adherent and suspended cells

  • Mar 05, 2021
  • Björn Kemper +4
  • Conference Article
  • Citations14

Advantages of digital holographic microscopy for real-time full field absolute phase imaging

  • Feb 07, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tristan Colomb +4
  • Conference Article

Overview of the automatic reconstruction method for quantitative phase imaging using a digital holographic microscope operating in non-telecentric regime

  • Mar 16, 2023
  • Brian Bogue-Jimenez +2
  • Conference Article

Single-shot capture bright-field and digital holographic microscopy for the analysis of living cells

  • May 16, 2023
  • Jose Angel Picazo-Bueno +5
  • Research Article
  • Citations1

Low-coherence digital holographic microscope with a Fizeau interferometer.

  • Feb 06, 2026
  • Applied optics
  • Mohit Rathor +3
  • Conference Article
  • Citations7

Automated detection of macrophages in quantitative phase images by deep learning using a mask region-based convolutional neural network

  • Mar 05, 2021
  • Kai Eder +5
  • Conference Article
  • Citations5

Reduction of the influence of parasitic interferences and coherence induced disturbances in digital holography-based quantitative phase microscopy by modulation of the object illumination with an electrically focus tunable lens

  • Mar 05, 2021
  • Björn Kemper +6
  • Research Article

Simultaneous digital holographic microscopy and Fourier transform spectroscopy

  • Sep 01, 2024
  • Iranian Journal of Physics Research
  • Lotfi, Maryam +2
  • Conference Article

Label-free assessment of intestinal inflammation in patients with ulcerative colitis using digital holographic microscopy

  • Jan 01, 2024
  • A Bokemeyer +9
Cactus Communications logo