• Home
  • Search
  • A primary human Gut/Liver microphysiological system to estimate human oral bioavailability
  • Cite Icon1
  • https://doi.org/10.1016/j.dmd.2025.100130Copy DOI Icon

A primary human Gut/Liver microphysiological system to estimate human oral bioavailability

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Oral bioavailability is a crucial pharmacokinetic (PK) parameter optimized by drug developers working on new therapeutic compounds. The goal is to obtain adequate systemic exposure and to establish safe and effective therapeutic dosages. Critical to optimizing oral bioavailability is understanding a compound’s susceptibility to first-pass metabolism, determined by the intricate relationship between gut absorption, metabolism, and hepatic metabolism. Efforts to model this relationship in vitro have led to the emergence of microphysiological systems (MPSs) that consist of multiple, fluidically linked organs. Here, we describe an MPS that links the gut and liver, capable of simulating both oral and intravenous dosing routes and is made up of entirely primary human cells: a gut barrier tissue comprised of an intestinal epithelial monolayer derived from the human jejunum, and a liver microtissue, derived from primary human hepatocytes. Functionality of gut and liver tissues is maintained in coculture enabling the PK investigation of oral compounds. We combine the primary Gut/Liver MPS with a mechanistic mathematical model to generate organ-specific PK parameters and estimate human oral bioavailability and its components: the fraction absorbed (Fa), the fraction escaping gut wall elimination (Fg), and the fraction escaping hepatic elimination (Fh). We used the CYP3A-mediated compound midazolam, which is subjected to both intestinal and hepatic extraction, to demonstrate the transformative potential of the primary Gut/Liver MPS to mechanistically model the PKs of oral compounds in vitro.Significance StatementBioavailability underpins the success or when insufficient, can stall the development of oral therapeutics. The drug discovery process lacks in vitro assays that can profile the contribution to bioavailability by the gut and liver. The primary Gut/Liver MPS outlined in this study bridges this gap.

Similar Papers
  • Research Article
  • Citations25

Dynamic microphysiological system chip platform for high-throughput, customizable, and multi-dimensional drug screening

  • May 17, 2024
  • Bioactive Materials
  • Yuxuan Zhu +10
  • Research Article
  • Citations4

Comparative analysis of Caco-2 cells and human jejunal and duodenal enteroid-derived cells in gel- and membrane-based barrier models of intestinal permeability.

  • Jan 30, 2025
  • Toxicological sciences : an official journal of the Society of Toxicology
  • Haley L Moyer +11
  • PDF
  • Supplementary Content
  • Citations15

Building blocks of microphysiological system to model physiology and pathophysiology of human heart

  • Jul 06, 2023
  • Frontiers in Physiology
  • Hanna Vuorenpää +7
  • Research Article
  • Citations10

Perfluoropolyether-Based Gut-Liver-on-a-Chip for the Evaluation of First-Pass Metabolism and Oral Bioavailability of Drugs.

  • Jun 01, 2024
  • ACS biomaterials science & engineering
  • Mengyang Wang +12
  • Research Article
  • Citations104

Impact of physiological, physicochemical and biopharmaceutical factors in absorption and metabolism mechanisms on the drug oral bioavailability of rats and humans

  • Aug 01, 2007
  • Expert Opinion on Drug Metabolism & Toxicology
  • Susan Hurst +3
  • Research Article

Attempts to Improve Non-clinical Evaluation Predictability by In Vivo Imaging and Microphysiological Systems: The Cases of the CNS Seizure Risk Assessment and Drug Delivery to the Alveoli

  • Jun 01, 2025
  • Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan
  • Kaoru Sato +2
  • Research Article

Construction of Microphysiological System by Integration of Cells and Microdevices

  • Sep 10, 2024
  • Vacuum and Surface Science
  • Yuya Morimoto
  • Research Article
  • Citations19

A thermoplastic microfluidic microphysiological system to recapitulate hepatic function and multicellular interactions.

  • Oct 15, 2019
  • Biotechnology and Bioengineering
  • Shyam Sundhar Bale +13
  • Research Article
  • Citations13

Cyclo olefin polymer-based solvent-free mass-productive microphysiological systems

  • Mar 01, 2021
  • Biomedical Materials
  • Makoto Yamanaka +5
  • Research Article
  • Citations5

Innervated adrenomedullary microphysiological system to model nicotine and opioid exposure

  • Oct 22, 2021
  • Organs-on-a-chip
  • Jonathan R Soucy +6
  • Research Article
  • Citations5

Mera: A scalable high throughput automated micro-physiological system.

  • Aug 01, 2023
  • SLAS Technology
  • Finola E Cliffe +12
  • Research Article
  • Citations4

Human quad liver-on-chip system as a tool toward bridging the gap between animals and humans regarding toxicology and pharmacology of a cannabidiol-rich cannabis extract

  • Aug 05, 2024
  • Drug and Chemical Toxicology
  • Laura E Ewing +11
  • Research Article
  • Citations67

Interleukin-4 (IL-4) and IL-13 Enhance the Effect of IL-1β on Production of IL-1 Receptor Antagonist by Human Primary Hepatocytes and Hepatoma HepG2 Cells: Differential Effect on C-Reactive Protein Production

  • Feb 15, 1999
  • Blood
  • Cem Gabay +4
  • Research Article
  • Citations10

Rapid Biofabrication of an Advanced Microphysiological System Mimicking Phenotypical Heterogeneity and Drug Resistance in Glioblastoma

  • Aug 05, 2024
  • Advanced Healthcare Materials
  • Sirjana Pun +6
  • PDF
  • Research Article
  • Citations269

Functional Coupling of Human Microphysiology Systems: Intestine, Liver, Kidney Proximal Tubule, Blood-Brain Barrier and Skeletal Muscle

  • Feb 08, 2017
  • Scientific Reports
  • Lawrence Vernetti +21
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.