• Home
  • Search
  • A rectangular birdcage coil for MRI of the hand
  • https://doi.org/10.1109/nssmic.1992.301522Copy DOI Icon

A rectangular birdcage coil for MRI of the hand

  • Oct 25, 1992
  • T Vullo +2 more
Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Summary form only given, as follows. A new type of birdcage coil having a rectangular geometry has been developed for MRI (magnetic resonance imaging) of the hand. This coil was analyzed using validated theoretical models for standard cylindrical birdcages. The effective circuit elements were determined and compared for comparable cylindrical and rectangular birdcage coils, and RF field mapping was performed. The SNR of the rectangular coil was 240% greater than that of a comparable cylindrical version. This was consistent with a reduction of noise due to decreased volume and a 22% greater sensitivity (from the field plots) of the rectangular coil compared to the cylindrical version. High-resolution hand images further demonstrated the utility of this type of coil for MRI. >

Similar Papers
  • Research Article
  • Citations5

Multiple Parallel Round Leg Design for Quadrature Birdcage Coil in Ultrahigh-Field MRI

  • Dec 11, 2017
  • Applied Magnetic Resonance
  • Yongfeng Xu +3
  • Research Article

Design of miniatured MRI coils for MRI‐guided tumor diagnosis and hyperthermia therapy

  • Jan 23, 2024
  • Microwave and Optical Technology Letters
  • Sakthisudhan Karuppanan +3
  • Research Article
  • Citations2

A proton birdcage coil integrated with interchangeable single loops for multi-nuclear MRI/MRS.

  • Feb 01, 2024
  • Journal of Zhejiang University-SCIENCE B
  • Yi Zhang +6
  • Research Article

Radio Frequency MRI coils

  • Jan 01, 2020
  • European Journal of Clinical and Experimental Medicine
  • Adrian Truszkiewicz +4
  • Conference Article
  • Citations1

Calculation of SAR and B/sub 1/-field within human head excited by MRI birdcage coils

  • Nov 23, 2002
  • J Chen +1
  • Conference Article

Folded crossed-ellipse coil for hand magnetic resonance imaging

  • Sep 17, 2003
  • R Hernandez +3
  • Research Article
  • Citations71

Counter rotating current local coils for high-resolution magnetic resonance imaging.

  • Aug 01, 1986
  • Magnetic resonance in medicine
  • W Froncisz +3
  • Research Article
  • Citations8

Design and Simulation of a Birdcage Coil using CST Studio Suite for Application at 7T

  • Dec 16, 2013
  • IOP Conference Series: Materials Science and Engineering
  • Bernat Palau Tomas +2
  • Research Article
  • Citations4

An Extended Theory and Method for Double-Tuned Conformal Birdcage Coil in MRI

  • Jan 01, 2024
  • IEEE Transactions on Instrumentation and Measurement
  • Junyao Xie +6
  • Research Article
  • Citations112

64‐channel array coil for single echo acquisition magnetic resonance imaging

  • Jul 19, 2005
  • Magnetic Resonance in Medicine
  • Mary Preston Mcdougall +1
  • Research Article
  • Citations299

Suspected local recurrence after radical prostatectomy: endorectal coil MR imaging.

  • Apr 02, 2004
  • Radiology
  • Tamar Sella +6
  • Research Article
  • Citations10

Analysis of the noise correlation in MRI coil arrays loaded with metamaterial magnetoinductive lenses.

  • Dec 05, 2014
  • IEEE Transactions on Medical Imaging
  • Jose M Algarin +3
  • Research Article
  • Citations3

Extending a birdcage coil for magnetic resonance imaging of a human head with an artificial magnetic shield

  • Dec 26, 2020
  • Photonics and Nanostructures - Fundamentals and Applications
  • K Lezhennikova +4
  • Research Article
  • Citations10

Transmission line analysis of noncylindrical birdcage resonators

  • Jan 01, 1994
  • Magnetic Resonance Imaging
  • Thomas Vullo +4
  • Research Article

Full-Wave Simulation of a Solenoid RF Coil for Small Animal Magnetic Resonance Imaging with a Clinical Scanner.

  • Apr 23, 2025
  • Sensors (Basel, Switzerland)
  • Giulio Giovannetti +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.