• Home
  • Search
  • A simulation study evaluating the performance of high-density electrode arrays on myocardial tissue.
  • Cite Icon18
  • https://doi.org/10.1109/10.846683Copy DOI Icon

A simulation study evaluating the performance of high-density electrode arrays on myocardial tissue.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Multielectrode arrays used to detect cellular activation have become so dense (electrodes per square millimeter) as to jeopardize the basic assumptions of activation mapping; namely, that electrodes are points adequately separated as to not interfere with the tissue or each other. This paper directly tests these assumptions for high-density electrode arrays. Using a finite element model with modified Fitzhugh-Nagumo kinetics, we represent electrodes as isopotential surfaces of varying widths and spacing ratio (SR) (center-to-center spacing divided by electrode width). We examine the signal strength and ability of a single electrode to detect activation due to a passing wavefront. We find that high-density arrays do not cause significant wavefront curvature or alter activation timing in the underlying tissue. Relationships between signal strength, cross talk, and array design are explained by the interaction of the propagating wavefront and induced sources on the isopotential electrodes. Sensitivity analysis shows that these results may be generalized to a wide range of physiologically relevant designs and applications. We conclude that electrode array designs in which electrode spacing greatly exceeds electrode diameter are overly conservative and that arrays with a SR of less than 2.0 may perform successfully in electrophysiological studies.

Similar Papers
  • Research Article
  • Citations2

Parasitic Capacitance in High-Density Neural Electrode Arrays: Sources and Evaluation Methods.

  • Jan 01, 2024
  • IEEE transactions on bio-medical engineering
  • A Ghazavi +2
  • Research Article

1008 Intraoperative Localization of a Novel 1024-Contact High-Density Electrode Array for Advanced Neural Decoding

  • Apr 01, 2025
  • Neurosurgery
  • Pierce Hunter Davis +12
  • Conference Article
  • Citations11

Current steering and current focusing with a high-density intracochlear electrode array

  • Aug 01, 2011
  • Jessica D Falcone +1
  • Conference Article
  • Citations48

High-Density Flexible Parylene-Based Multielectrode Arrays for Retinal and Spinal Cord Stimulation

  • Jan 01, 2007
  • D.C Rodger +14
  • Research Article
  • Citations22

An automated system for rapid evaluation of high-density electrode arrays in neural prostheses

  • Apr 15, 2011
  • Journal of Neural Engineering
  • Sam E John +7
  • PDF
  • Research Article
  • Citations4

ADS1299-Based Array Surface Electromyography Signal Acquisition System

  • Dec 01, 2022
  • Journal of Physics: Conference Series
  • Yuchang Li +2
  • Research Article

Abstract 18867: High Density Electrical Mapping With Conformal Electrode Arrays

  • Nov 26, 2013
  • Circulation
  • Leon Ptaszek +12
  • Research Article
  • Citations6

A Novel Exoskeleton Neuromuscular Interface Based on Motor Unit Action Potential Model Using High-Density sEMG

  • Jan 01, 2024
  • IEEE Transactions on Instrumentation and Measurement
  • Weibo Wang +6
  • Supplementary Content
  • Citations1

Development of Flexible Parylene-Based Microtechnologies for Retinal and Spinal Cord Stimulation and Recording

  • Jan 01, 2008
  • Europe PMC (PubMed Central)
  • Damien C Rodger
  • Research Article
  • Citations334

Flexible parylene-based multielectrode array technology for high-density neural stimulation and recording

  • Nov 12, 2007
  • Sensors and Actuators B: Chemical
  • D Rodger +9
  • Research Article
  • Citations9

Laser ablation of the pia mater for insertion of high-density microelectrode arrays in a translational sheep model

  • Jun 11, 2021
  • Journal of Neural Engineering
  • Kevin M Boergens +9
  • Research Article
  • Citations45

Why ‘the bigger the better’ is not always the case when utilising microelectrode arrays: high density vs. low density arrays for the electroanalytical sensing of chromium(vi)

  • Jan 01, 2009
  • The Analyst
  • Sebastian J Hood +6
  • Research Article
  • Citations10

Comparison of Speech Recognition and Localization Ability in Single-sided Deaf Patients Implanted With Different Cochlear Implant Electrode Array Designs.

  • Sep 23, 2020
  • Otology & Neurotology
  • Iva Speck +5
  • Research Article
  • Citations10

High-Density Multichannel Electrode Array Improves the Accuracy of Cutaneous Electrogastrography Across Subjects With Wide-Ranging BMI

  • Oct 01, 2018
  • American Journal of Gastroenterology
  • Armen A Gharibans +3
  • Research Article
  • Citations68

Multiscale functional connectivity estimation on low-density neuronal cultures recorded by high-density CMOS Micro Electrode Arrays

  • Apr 09, 2012
  • Journal of Neuroscience Methods
  • Alessandro Maccione +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.