A simulation tool for x-ray phase-contrast micro-CT featuring a small-pixel photon-counting detector

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Abstract X-ray micro-CT (µCT) is an important tool for high-resolution, non-destructive inspection of samples with numerous applications ranging from preclinical imaging to materials science. µCT imaging capabilities can be expanded through the use of small-pixel ( < 100 µm) photon-counting detectors (PCDs) which increase image contrast, reduce image noise, and provide additional insights into material composition through the collected spectral information. Along the same lines, phase-contrast x-ray imaging is increasingly being adopted in laboratory µCT imaging setups to improve the visualization of low-attenuation contrast samples. Along with these technological improvements comes the need for improved modeling and simulation. However, no laboratory µCT simulation tool currently exists that includes a small-pixel PCD. PEPIsim addresses this need, providing a simulation resource that produces photon-counting, spectral, and phase-contrast µCT reconstructions, accurately modelling the response of the small-pixel PCD in addition to incorporating phase-contrast effects. PEPIsim has been benchmarked against experimental images of a custom plastic phantom acquired with a µCT setup featuring a PCD and a micro-focus x-ray tube. Results show that the simulation reproduces the system spectral response (average NMRSE of 2.7%) across a wide range of tube voltages (45–100 kVp). Moreover, good accuracy in terms of measured x-ray attenuation (average relative error (RE) of 1.5%) and SNR (average RE of 6.5%) has been found. Similarly, after phase-retrieval, the simulated images’ SNR is found to be in agreement with experimental images (average RE of 5.5%). Finally, the simulation can also reproduce the fringe visibility due to the edge-enhancement effect (average RE of 5.2%) across a range of magnifications (from 1.3 to 3.7) and source to detector distances (from 40 to 133 cm). Due to its modular structure, PEPIsim can be adapted to any experimental µCT imaging setup, provided that accurate detector and x-ray tube models exist.

Similar Papers
  • Research Article
  • Citations1

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source

  • Jan 01, 2015
  • Progress in Medical Physics
  • Yeonok Park +8
  • PDF
  • Research Article
  • Citations1

Microfocus X-ray Tubes

  • Nov 29, 2021
  • Journal of the Russian Universities. Radioelectronics
  • V B Bessonov
  • Research Article

Comparison of inline and edge-illumination x-ray phase contrast imaging for atherosclerotic plaque visualization

  • Nov 05, 2025
  • Journal of Physics D: Applied Physics
  • Edilio Steven Cely Iza +2
  • Conference Article
  • Citations16

Energy calibration of photon counting detectors using x-ray tube potential as a reference for material decomposition applications

  • Mar 18, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Mini Das +3
  • Conference Article
  • Citations5

Transmission-type Window of HFCVD Diamond Film for Microfocus X-ray Tube

  • Jan 01, 2016
  • Lei Zheng +2
  • Research Article
  • Citations45

Source size and temporal coherence requirements of coded aperture type x-ray phase contrast imaging systems

  • Sep 01, 2010
  • Optics Express
  • Peter R T Munro +3
  • Research Article
  • Citations10

Application of Fourier-wavelet regularized deconvolution for improving image quality of free space propagation x-ray phase contrast imaging

  • Oct 24, 2012
  • Physics in Medicine and Biology
  • Zhongxing Zhou +3
  • Research Article
  • Citations8

Edge illumination x-ray phase contrast simulations using the CAD-ASTRA toolbox.

  • Mar 05, 2024
  • Optics Express
  • Nicholas Francken +4
  • Research Article
  • Citations29

Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience.

  • Mar 02, 2023
  • RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
  • Thomas Stein +15
  • Research Article
  • Citations31

A Microfocus X-ray Tube Used with Focusing Collimators

  • Dec 01, 1998
  • Journal of Applied Crystallography
  • U W Arndt +2
  • Research Article
  • Citations23

A single-image retrieval method for edge illumination X-ray phase-contrast imaging: Application and noise analysis

  • Nov 09, 2016
  • Physica Medica
  • Paul C Diémoz +9
  • Research Article
  • Citations4

Spectral X-ray phase contrast imaging with a CdTe photon-counting detector

  • May 06, 2020
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Carlos Navarrete +7
  • Research Article
  • Citations84

Transmission-type microfocus x-ray tube using carbon nanotube field emitters

  • Apr 30, 2007
  • Applied Physics Letters
  • Sung Hwan Heo +2
  • Abstract

OA248] Computer-based platform for phase contrast breast imaging

  • Aug 01, 2018
  • Physica Medica
  • Kristina Bliznakova +4
  • Research Article

Development of lightweight self-compacting concrete incorporating waste-expanded polystyrene using hybrid approach

  • Oct 04, 2024
  • International Journal of Pavement Engineering
  • Mahalingam Seethapathi +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.