• Home
  • Search
  • A study on vortex separator technology to control combined sewer overflow
  • https://doi.org/10.32920/ryerson.14661471.v1Copy DOI Icon

A study on vortex separator technology to control combined sewer overflow

  • Jun 8, 2021
  • Nawshin Rummnan
Show More
  • Abstract
  • Highlights & Summary
  • Literature Map
  • Similar Papers
Abstract

A combined-sewer overflow (CSO) is a significant contributor of contamination to surface waters. During a rain event, the flow in a combined sewer system (CSS) may exceed the capacity of the intercepting sewer leading to a wastewater treatment plant, thus releasing a mixture of storm water and raw sanitary wastewater into the receiving water. As CSOs contain untreated domestic, commercial, and industrial wastes, as well as surface runoff, many different types of contaminants can be present. Because of these contaminants and the volume of the flows, CSOs can cause a variety of adverse impacts on the physical characteristics of surface water, impair the viability of aquatic habitats, and pose a potential threat to drinking water supplies. The resulting short-term problems are poor aesthetics (floatables, turbidity, oil and grease), and beach closure due to increased harmful bacteria levels. The long term impacts include reduced dissolved oxygen in receiving waters, eutrophication and sediment contamination. Since CSO is considered to be a major source of water quality impairment for the receiving waters, much attention has been directed to reducing the quantity and quality of CSO discharged to meet the Ministry of Environment guidelines. There are several approaches to control the quantity and quality of CSO. The selection of a particular treatment technology depends on various factors such as site conditions, CSO characteristics, receiving water requirements. One of the emerging options is the vortex separator technology for High Rate Treatment (HRT) facilities at overflow location. There are many devices for CSO control in different trade names where vortex separator technology has been used (e.g. EPA Swirl Concentration, FluidSep(TM), Storm King(TM), CDS®). This study articulates the different CSO control technologies with emphasized [sic] on vortex separator technology. The City of Niagara Falls HRT pilot project for CSO control to the Niagara River is presented as a case study in this report. The performance of two HRT devices - Storm King(TM) and CDS® are evaluated in the pilot project. Analytical Probabilistic Model has been used a a tool in this study to evaluate the potential pollution reduction at the Niagara Falls CSO system.

Similar Papers
  • Research Article
  • Citations12

Influence of particle size on diffuse particulate pollutants in combined sewer systems

  • Jul 20, 2022
  • Science of The Total Environment
  • Lian Hu +1
  • Research Article
  • Citations43

Quantitative analysis of impact of green stormwater infrastructures on combined sewer overflow control and urban flooding control

  • May 21, 2017
  • Frontiers of Environmental Science & Engineering
  • Jinsong Tao +3
  • Research Article
  • Citations21

Effects of combined sewer overflows and storm water drains on metal bioavailability in small urban streams (Prague metropolitan area, Czech Republic)

  • Dec 16, 2015
  • Journal of Soils and Sediments
  • Dana Komínková +2
  • Research Article
  • Citations205

Organic micropollutants discharged by combined sewer overflows – Characterisation of pollutant sources and stormwater-related processes

  • Jul 31, 2016
  • Water Research
  • Marie A Launay +2
  • PDF
  • Research Article
  • Citations5

Water depth prediction in combined sewer networks, application of generative adversarial networks

  • Mar 11, 2024
  • Discover Applied Sciences
  • Alireza Koochali +8
  • Research Article
  • Citations12

Optimization of CSO Storage and Treatment Systems

  • Mar 01, 1997
  • Journal of Environmental Engineering
  • Richard Field +1
  • Conference Article

Design and Implementation of a Water Quality Field Monitoring Program in Support of CSO Long Term Control Planning

  • Jul 13, 2005
  • Charles M Poskas +1
  • Conference Article
  • Citations1

Not in My Front Yard: Overcoming Public Resistance to Urban GSI Retrofit Projects

  • Jan 12, 2015
  • Kristine Cramer
  • Research Article
  • Citations29

Evaluation of the factors relating combined sewer overflows with sediment contamination of the lower Passaic River

  • Mar 01, 1996
  • Marine Pollution Bulletin
  • N.M Shear +4
  • Research Article
  • Citations52

Hydrodynamic modelling of the influence of stormwater and combined sewer overflows on receiving water quality: Benzo(a)pyrene and copper risks to recreational water

  • Nov 15, 2017
  • Journal of Environmental Management
  • Karin Björklund +4
  • Research Article
  • Citations49

Optimization of Real‐Time Control With Green and Gray Infrastructure Design for a Cost‐Effective Mitigation of Combined Sewer Overflows

  • Dec 01, 2021
  • Water Resources Research
  • Marie‐Ève Jean +4
  • PDF
  • Research Article
  • Citations10

Effects of combined sewer overflow on water quality: a case study of Hatirjheel Lake in Dhaka

  • Oct 15, 2022
  • SN Applied Sciences
  • M Atauzzaman +1
  • Conference Article
  • Citations1

Predicting CSOs for Real Time Decision Support

  • May 12, 2009
  • World Environmental and Water Resources Congress 2009
  • D J Hill +2
  • Book Chapter
  • Citations10

Macro and Microplastics in Stormwater and Combined Sewer Overflows in Paris Megacity

  • Jan 01, 2020
  • Robin Treilles +7
  • Research Article
  • Citations47

Real-time control in combined sewer systems in Germany––some case studies

  • Jun 04, 2002
  • Urban Water
  • Michael Weyand
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.