Abstract

Most IMRT techniques have been designed to treat targets smaller than the field size of conventional linac accelerators. In order to overcome the field size restrictions in applying IMRT, we developed a two isocenter IMRT technique to treat long volume targets. The technique exploits an extended dose gradient throughout a junction region of 4–6 cm to minimize the impact of field match errors on a junction dose and manipulates the inverse planning and IMRT segments to fill in the dose gradient and achieve dose uniformity. Techniques for abutting both conventional fields with IMRT (‘Static + IMRT’) and IMRT fields (‘IMRT + IMRT’) using two separate isocenters have been developed. Five long volume sarcoma cases have been planned in Pinnacle (Philips, Madison, USA) using Elekta Synergy and Varian 2100EX linacs; two of the cases were clinically treated with this technique. Advantages were demonstrated with well-controlled junction target uniformity and tolerance to setup uncertainties. The junction target dose heterogeneity was controlled at a level of ±5%; for 3 mm setup errors at the field edges, the junction target dose changed less than 5% and the dose sparing to organs at risk (OARs) was maintained. Film measurements confirmed the treatment planning results.

Similar Papers
  • PDF
  • Research Article
  • Citations1

Dosimetric comparison of radiotherapy treatment plans done by IMRT and VMAT technique in head and neck cancer patients

  • May 31, 2021
  • International Journal of Medical Research & Review
  • Dr Aparajeeta Aparajeeta +3
  • Research Article

SU‐FF‐T‐151: In‐Vivo Diode Dosimetry for IMRT Treatment Dose Verification

  • May 26, 2005
  • Medical Physics
  • S Tong +6
  • PDF
  • Research Article

Adaptation of Unified Dosimetry Index (UDI) and Critical Organ Scoring Index (COSI) for Target and Organ at Risk (OAR) in Prostate IMRT Technique

  • Jan 01, 2020
  • Chemistry and Materials Research
  • Memoona Kousar
  • Research Article

Simultaneous integrated boost on hypoxic region by means of setup errors for pancreatic cancer SBRT

  • Dec 25, 2018
  • Zhonghua fangshe yixue yu fanghu zazhi
  • Chao Li +5
  • Abstract

Comparison of Treatment Plan Robustness Between Dynamic Trajectory Radiotherapy and VMAT

  • Oct 23, 2020
  • International Journal of Radiation Oncology*Biology*Physics
  • M.K Fix +7
  • Abstract

Dosimetric Implication of Neural Planning Organ at Risk Volumes in Stereotactic BodyRadiation Therapy of the Spine

  • Sep 23, 2017
  • International Journal of Radiation Oncology*Biology*Physics
  • S.H Jeon +5
  • Abstract

Post-mastectomy adjuvant internal mammary lymph node irradiation — benefit and cardiac toxicity: an Indian experience

  • Mar 01, 2004
  • EJC Supplements
  • S Saha +2
  • Research Article
  • Citations1

Effects of the setup errors on dose distribution of target area and organs at risk for prostate cancer

  • Jan 15, 2019
  • Chinese Journal of Radiation Oncology
  • Shirui Qin +1
  • Research Article

Does deformation of immobilization devices impact treatment accuracy in thoracic cancer radiotherapy?

  • Dec 18, 2024
  • Journal of Applied Clinical Medical Physics
  • Lianzi Zhao +3
  • Research Article

Comparative dosimetric evaluation of single-beam dual-arc versus dual-beam single-arc volumetric modulated arc therapy strategies in lung stereotactic body radiotherapy using Monaco

  • Nov 03, 2025
  • PeerJ
  • Jieni Ding +4
  • Conference Article

Evaluation of dosage effect of position numbers in IMRT for breast cancer

  • Oct 01, 2016
  • Yuan Zhao +1
  • Research Article

Prescription dose and optimisation strategies in MR-guided online adaptive radiotherapy for kidney tumours: a two-step planning analysis

  • Jul 05, 2025
  • Radiation Oncology
  • Takaya Yamamoto +11
  • Research Article

Evaluating the Ethos automated planning system for spatially fractionated radiotherapy

  • Oct 01, 2025
  • Journal of Applied Clinical Medical Physics
  • A Aziz Sait +6
  • Research Article
  • Citations114

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

  • Mar 06, 2012
  • International Journal of Radiation Oncology*Biology*Physics
  • Winnie Li +5
  • Research Article

SU‐E‐T‐687: Reverse Auto‐Planning: Assessing Dose Escalation in Pancreatic Stereotactic Radiotherapy From a Shape Database of Prior Patients

  • Jun 01, 2013
  • Medical Physics
  • J Moore +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.