• Home
  • Search
  • A Two-Wired Ultra-High Input Impedance Active Electrode.
  • Open Access IconOpen Access
  • Cite Icon39
  • https://doi.org/10.1109/tbcas.2018.2796581Copy DOI Icon

A Two-Wired Ultra-High Input Impedance Active Electrode.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This paper presents a novel two-wired active electrode that achieves ultrahigh input impedance using power supply bootstrapping. The proposed circuit reduces the input capacitance of a buffer amplifier while enabling measurements using leads with only two wires, providing a low-complexity and low-cost solution for interference rejection and artifact reduction in dc-coupled dry-contact biopotential measurements. An implemented prototype shows that, even using standard operational amplifiers, an input capacitance as low as 71 fF can be obtained, maintaining a high impedance in a 0-1 kHz bandwidth, sufficient for ECG, EEG, and EMG measurements. The circuit has a simple and easily replicable implementation that requires no individual adjustment. A common mode rejection ratio (CMRR) above 103 dB at 50Hz was achieved and the increased rejection to interference due to the potential divider effect was experimentally tested maintaining a 92-dB CMRR at 50Hz with a 1.2-M source impedance unbalance. ECG measurements were conducted to validate the active electrode against a traditional alternative, and a test with dry-contact EEG electrodes was successfully conducted. Although the proposed circuit is intended to acquire superficial electrophysiological signals using dry electrodes, it can be used for measurement from other high-impedance sources, such as micropipette electrodes.

Similar Papers
  • Dissertation

Integrated circuit design methods for biosignal measurements with high input impedance requirements

  • Jan 01, 2024
  • Safaa Ahmed Mohamed Abdelfattah
  • PDF
  • Research Article
  • Citations6

Electrospun Rubber Nanofiber Web-Based Dry Electrodes for Biopotential Monitoring

  • Aug 24, 2023
  • Sensors (Basel, Switzerland)
  • Mohammad Shamim Reza +5
  • Research Article
  • Citations46

A 2.55 NEF 76 dB CMRR DC-Coupled Fully Differential Difference Amplifier Based Analog Front End for Wearable Biomedical Sensors.

  • Jun 24, 2019
  • IEEE Transactions on Biomedical Circuits and Systems
  • Yang Zhao +2
  • Book Chapter
  • Citations2

8-Lead Bioelectrical Signals Data Acquisition Unit

  • Jan 01, 2019
  • Tadeáš Bednár +2
  • Conference Article
  • Citations3

Low-voltage high CMRR OTA for electrophysiological measurements

  • May 01, 2009
  • Srinjoy Mitra +2
  • Conference Article
  • Citations2

A 100 dB CMRR CMOS operational amplifier with single-supply capability

  • Dec 13, 2004
  • V Ivanov +2
  • Research Article
  • Citations15

An 800MΩ-Input-Impedance 95.3dB-DR Δ-ΔΣ AFE for Dry-Electrode Wearable EEG Recording.

  • Oct 01, 2024
  • IEEE transactions on biomedical circuits and systems
  • Yuying Li +4
  • Conference Article
  • Citations3

High PSRR Folded Cascode OTA for Neural Signal Applications

  • Oct 29, 2021
  • M Lopez-Solis +6
  • Research Article
  • Citations16

A Novel Front-End Design for Bioelectrical Signal Wearable Acquisition

  • Sep 15, 2019
  • IEEE Sensors Journal
  • Jianwen Ding +5
  • PDF
  • Research Article
  • Citations1

Neuronal network analysis during short time transcranial direct current stimulation with permanent EEG measurement in early childhood: a feasibility study.

  • May 27, 2025
  • Journal of neural transmission (Vienna, Austria : 1996)
  • Hannes Brehme +3
  • Conference Article
  • Citations36

English

  • Jan 01, 2014
  • Alexandra-Maria Tăuțan +5
  • Research Article
  • Citations5

Effect of electrode impedance in improved buffer amplifier for bioelectric recordings

  • Jan 01, 2004
  • Journal of Medical Engineering & Technology
  • Er Valverde +4
  • Research Article
  • Citations19

Development of soft dry electrodes: from materials to structure design

  • Aug 02, 2023
  • Soft Science
  • Hua Liu +6
  • Research Article
  • Citations2

Design of a floating-ground-electrode circuit for measuring attenuation of the human body channel.

  • May 20, 2020
  • Technology and Health Care
  • Yiwen Zhang +4
  • Conference Article
  • Citations3

Compensation of Mismatch Electrodes Impedances in Biopotential Measurement

  • Apr 20, 2006
  • I.S.S Silva +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.