• Home
  • Search
  • Accelerated Degradation Test on Electric Scroll Compressor Using Controlled Continuous Liquid Slugging
  • Cite Icon1
  • https://doi.org/10.36001/phmconf.2023.v15i1.3525Copy DOI Icon

Accelerated Degradation Test on Electric Scroll Compressor Using Controlled Continuous Liquid Slugging

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Refrigerant-based electric scroll compressors are known for their reliability, efficiency, and quiet operation. They are often used in heat pump systems due to their ability to efficiently handle varying levels of load conditions, both for heating and cooling modes of operation. As electric compressors are considered the heart of the heat pump system, being able to determine degradation of compressors prior to failure is of paramount importance for the health of this system. Typical failures for electric scroll compressors range from electrical faults, refrigerant leaks, to mechanical failures and overheating. Specifically, one of the primary failure modes for an electric scroll compressor is mechanical damage due to the high stress effects of refrigerant liquid slugging. These stresses are due to excessively high internal pressures exhibited on the compressor scrolls, which are generated by compressing liquid refrigerant at the suction side of the compressor. This paper provides a new testing methodology that introduces liquid slugging at various degrees of refrigerant quality to degrade a compressor to near the end of useful life. Furthermore, this test aims to determine specific operating conditions and signals that can indicate early compressor degradation. This fault injection configuration consists of a modified heat pump system with the addition of two low pressure heat exchangers added in parallel (with respective electronically controlled expansion valve for each heat exchanger) used to control the refrigerant quality during compressor operations. For a given refrigerant quality, the heat pump system was operated at a fixed compressor performance conditions to sustain liquid slugging for a fixed duration. Afterwards, refrigerant was controlled to be pure vapor at the compressor suction side and the compressor was controlled at several different performance conditions (i.e., fixed compressor suction superheat temperature and compressor pressure ratios, at various compressor speeds), so as to duplicate conditions known to us from the compressor component data sheet for an ideal electric scroll compressor. Through these tests, the results show that the severity of scroll failures depend heavily on the refrigerant quality and the amount of liquid slugging exposure time. Furthermore, symptoms of compressor degradation are detected using the following signals: i) temperature and pressure at the compressor suction side, ii) temperature and pressure at the compressor discharge side, and iii) electric compressor speed and power consumption. To further aid in determining the compressor degradation ground truth, complete compressor teardown was performed to identify sections within the compressor that exhibited significant amounts of wear as compared to a stock compressor.

Similar Papers
  • PDF
  • Research Article
  • Citations2

CONTROL OF A HEAT PUMP COMPRESSOR WITH VARIABLE FREQUENCY DEVICE DRIVEN BY PID

  • Feb 02, 2024
  • International Journal of Engineering and Innovative Research
  • Özdemir Deni̇z
  • Research Article
  • Citations1

Experimental investigation on dehumidification and heating performance of a heat pump system concerning dew or fog removal for electric vehicles

  • Oct 07, 2022
  • Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering
  • Jun Yu +1
  • Conference Article
  • Citations4

Numerical Evaluation of the Effects of Low Pressure EGR Mixer Configuration on Turbocharger Compressor Performance

  • Nov 04, 2018
  • Volume 2: Emissions Control Systems; Instrumentation, Controls, and Hybrids; Numerical Simulation; Engine Design and Mechanical Development
  • Amin Reihani +4
  • Research Article
  • Citations39

Experimental study of propane heat pump system with secondary loop and vapor injection for electric vehicle application in cold climate

  • Nov 01, 2022
  • Applied Thermal Engineering
  • Haimin Wang +5
  • Research Article
  • Citations39

Performance evaluation of an automotive air conditioning and heat pump system using R1234yf and R134a

  • Jun 29, 2020
  • Science and Technology for the Built Environment
  • Mumin Celil Aral +2
  • PDF
  • Research Article
  • Citations4

Experimental Research on the Output Performance of Scroll Compressor for Micro Scale Compressed Air Energy Storage System

  • Nov 06, 2023
  • Sustainability
  • Juan Fang +5
  • Research Article
  • Citations73

Performance assessment of a range-extended electric vehicle under real driving conditions using novel PCM-based HVAC system

  • Aug 26, 2021
  • Sustainable Energy Technologies and Assessments
  • Hanie Rezaei +3
  • Conference Article

Impact of Shift in Frequency of Online Water Washes on Corrected Isentropic Efficiency of Compressor of Heavy-Duty Gas Turbine

  • Jun 16, 2025
  • Muhammad Adnan Saroosh +4
  • Research Article

Simulation and experimental investigation on performance of heat pump scroll compressor with two-phase vapor injection

  • Feb 04, 2026
  • Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
  • Weitao Wang +4
  • Research Article
  • Citations1

Effect of housing surface roughness on the performance of a centrifugal compressor for turbocharger: Experimental and numerical study

  • Sep 29, 2021
  • International Journal of Engine Research
  • Ealumalai Karunakaran +2
  • Research Article
  • Citations23

Steady-state operation of a compressor for a proton exchange membrane fuel cell system

  • May 01, 2000
  • Journal of Applied Electrochemistry
  • D Thirumalai +1
  • PDF
  • Research Article
  • Citations12

Control-Oriented Modeling for Nonlinear MIMO Turbofan Engine Based on Equilibrium Manifold Expansion Model

  • Oct 02, 2021
  • Energies
  • Chengkun Lv +5
  • Research Article
  • Citations62

Experimental performance analysis of a direct-expansion solar-assisted heat pump water heater with R134a in summer

  • May 04, 2018
  • International Journal of Refrigeration
  • Xiangqiang Kong +4
  • Conference Article

Wet Gas Compressor Operation and Performance

  • Nov 09, 2018
  • Martin Bakken +2
  • Research Article
  • Citations8

Operation and Control of Helium Subcooling System of LHD Helical Coils During Change of Rotational Speed of Cold Compressors

  • Jun 01, 2010
  • IEEE Transactions on Applied Superconductivity
  • Shinji Hamaguchi +8
Cactus Communications logo