• Home
  • Search
  • Adaptive wavefront sensor for accurate characterization and evaluation of circular optical elements
  • Cite Icon1
  • https://doi.org/10.1117/12.2619488Copy DOI Icon

Adaptive wavefront sensor for accurate characterization and evaluation of circular optical elements

  • May 20, 2022
  • Rania M Abdelazeem +1 more
Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Shack-Hartmann wavefront sensor (SHWFS) is considered as an efficient and complementary tool in the field of optics metrology. It is widely used for evaluating and characterizing rigid glass and soft eye contact lenses. However, the presence of any type of aberrations will cause measurement errors decreasing the precision of the sensor. Therefore, in the current study an experimental configuration based on an active adaptive SHWFS was presented for optical testing of circular optical elements such as thin and soft eye contact lenses. As an adaptive element, deformable mirror (DM), was integrated to the SHWFS setup to dynamically compensate for the wavefront aberrations of the illumination laser beam to provide an ideal plane. The concept was firstly verified by measuring standard thin lenses then applied to measure soft eye contact lenses. For the quantitative evaluation, Zernike polynomials was used to accurately define the dominant modes of wavefront aberrations and thus to calculate the wavefront to be written on the DM. Based on the standard deviation (1σ) between the given and the measured focal lengths of the tested thin glass lenses, the measurements show an improvement of the measurement error from 15.18% difference of the uncompensated wavefront and 3.90% of the referencebased method to only 2.11% after aberration compensation of the illumination beam. While for the contact lenses, the measurement error was 22.93% for uncompensated aberrations, 51% for the reference-based method, and 1.75% after aberrations compensation. The results reveal that the aberrations of the illumination laser beam and the wet cell induced aberrations affect the accuracy of the measurements which can be drastically improved by compensating the existing aberrations utilizing the active adaptive SHWFS setup. In conclusion, adaptive-SHWFS can be considered as an in-production, accurate and complementary tool for testing of optical components.

Similar Papers
  • Research Article
  • Citations57

Measurement of wave-front aberration in soft contact lenses by use of a Shack–Hartmann wave-front sensor

  • Jul 20, 2005
  • Applied Optics
  • Tae Moon Jeong +2
  • Research Article
  • Citations8

Visual performance and aberration associated with contact lens wear in patients with keratoconus: a pilot study

  • Aug 01, 2014
  • Clinical Optometry
  • Bariah Mohd-Ali +2
  • Research Article
  • Citations47

Water Exposure is a Common Risk Behavior Among Soft and Gas-Permeable Contact Lens Wearers.

  • Apr 13, 2017
  • Cornea
  • Aaron B Zimmerman +12
  • Research Article
  • Citations3

Contact lens related corneal infiltrates and ulcers – a retrospective study of 134 eyes

  • Nov 01, 2008
  • Spektrum der Augenheilkunde
  • B Neumaier-Ammerer +3
  • Research Article

Evaluating the visual benefits of toric soft contact lenses using a novel pupil-controlled vision testing system.

  • Apr 01, 2025
  • Contact lens & anterior eye : the journal of the British Contact Lens Association
  • Michael Read +5
  • Conference Article
  • Citations1

A new wavefront measuring method of laser beam traversing a supersonic flow by using Hartmann-Shack wavefront sensor

  • Feb 23, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Xiang Zhang +3
  • Supplementary Content

Visual performance in myopic patients wearing daily-disposable multifocal soft contact lenses

  • Jan 01, 2020
  • Aston Publications Explorer (Aston University)
  • Chek Hoo Sim
  • Research Article
  • Citations7

International trends in prescribing silicone hydrogel contact lenses for daily wear (2000–2023): An update

  • Sep 14, 2024
  • Contact Lens and Anterior Eye
  • Nathan Efron +5
  • Single Report
  • Citations3

Initial Demonstration of Mercury Wavefront Correction System

  • Feb 01, 2006
  • Z Liao
  • Discussion

Letters to the Editor

  • Jan 01, 2001
  • Ophthalmology
  • Padmaja R Sankaridurg
  • Research Article
  • Citations16

Short and ultrashort antimicrobial peptides anchored onto soft commercial contact lenses inhibit bacterial adhesion

  • Jul 30, 2020
  • Colloids and Surfaces B: Biointerfaces
  • Emiliano Salvagni +7
  • Research Article

Visual Performance with Soft Hydrophilic Contact Lenses

  • Oct 01, 1985
  • American journal of optometry and physiological optics
  • Jonathan S Pointer +2
  • Research Article
  • Citations30

Through‐focus optical characteristics of monofocal and bifocal soft contact lenses across the peripheral visual field

  • Apr 24, 2018
  • Ophthalmic and Physiological Optics
  • Qiuzhi Ji +3
  • Conference Article

Multimodal characterization of contact lenses

  • Oct 12, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Michael A Marcus +4
  • Research Article
  • Citations7

Factors influencing the 8-item contact lens dry eye questionnaire score and comparison of translations in Japanese soft contact lens wearers

  • Oct 05, 2021
  • Contact Lens and Anterior Eye
  • Shizuka Koh +4