• Home
  • Search
  • Addressing Technical Failures in a Diabetic Retinopathy Screening Program [Letter]
  • Cite Icon1
  • https://doi.org/10.2147/opth.s465913Copy DOI Icon

Addressing Technical Failures in a Diabetic Retinopathy Screening Program [Letter]

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

We have read the paper written by Ian Gerard Brennan et al on Addressing Technical Failures in a Diabetic Retinopathy Screening Program. 1 We congratulate all authors who have provided important information regarding Diabetic Retinopathy (DR), which is a cause of blindness, through screening using digital retinal photography. DR is the most common cause of vision loss caused by damage to the small blood vessels in the retina. Regular eye examinations are essential to detect this disease to increase the chances of effective treatment. 2 Imaging technology for DR screening has advanced rapidly over the past few decades and produces images with higher resolution and contrast with less time, effort and invasiveness. A few, including optical coherence tomography (OCT), fluorescein or angiography and OCT oximetry which can provide dynamic and functional information regarding the current condition of the retina. 3 The study conducted by Ian Gerard Brennan et al used a screening protocol and DR assessment from patient data (patient demographics, screening results, and other factors) in the National Diabetic Retina Screening database for 2018 and 2022 for analysis. 1 The method used was appropriate with the objectives to be achieved, however, to carry out screening on DR patients, the following must be taken into account: (1) The examination method must be appropriate to the screening area, and the DR assessment system must be applied systematically and uniformly; (2) performed in an ophthalmology clinic; (3) staff conducting screening must be accredited; (4) screening programs must comply with relevant national quality assurance standards; (5) use uniform standards to determine optimal risk-based inspection intervals; (6) technological infrastructure must be in place to ensure that high-quality images can be stored securely to protect patient information. 4 In this research, Ian Gerard Brennan et al found that the type and duration of diabetes, dilated pupil status, and the presence of a lens on the device used for screening were significantly related to technical failure (TF). 1 Therefore we recommend that try Multimodal Imaging Techniques and Potential Future Directions which uses several imaging methods to check the quantity of retinal thickness and precise mapping of retinal topography. This is useful in assessing retinal thickness in non-clinically significant macular edema and clinically significant macular edema. 5 In conclusion we agree that it is important to carry out comprehensive interventions aimed at reducing TF rates and increasing the effectiveness of Diabetic Retina Screening programs to determine the significant impact of patient factors, especially cataracts, on TF rates. 1 As additional information, it is important to know that retinal imaging is a key component in the diagnosis and management of DR patients and a multimodal imaging approach is key, as multiple imaging modalities including dye-based fluorescein and optical coherence tomography angiography can provide clinically important complementary information. 3 All authors report no conflicts of interest in this communication.

Similar Papers
  • PDF
  • Research Article
  • Citations11

Quantitative assessment of OCT and OCTA parameters in diabetic retinopathy with and without macular edema: single-center cross-sectional analysis.

  • Mar 08, 2024
  • Frontiers in endocrinology
  • Yanyan Cui +10
  • Research Article
  • Citations7

Risk of retinal neovascularization in the second eye in patients with proliferative diabetic retinopathy

  • May 27, 2010
  • Acta Ophthalmologica
  • Edda Vésteinsdóttir +3
  • Research Article
  • Citations7

Results of a community-based screening programme for diabetic retinopathy and childhood blindness in district Hyderabad, Pakistan

  • Dec 01, 2017
  • BMJ Open Ophthalmology
  • Noor Bakht Nizamani +4
  • PDF
  • Research Article
  • Citations39

Current epidemiology of diabetic retinopathy in patients with type 1 diabetes: a national multicenter study in Brazil

  • Aug 08, 2018
  • BMC Public Health
  • Laura Gomes Nunes Melo +11
  • Discussion
  • Citations60

Artificial intelligence for diabetic retinopathy screening in Africa

  • May 01, 2019
  • The Lancet Digital Health
  • Wanjiku Ciku Mathenge
  • PDF
  • Research Article
  • Citations17

Use of personalised risk-based screening schedules to optimise workload and sojourn time in screening programmes for diabetic retinopathy: A retrospective cohort study.

  • Oct 17, 2019
  • PLoS medicine
  • Andreas Ochs +9
  • Research Article

Inter-grader agreement in the diabetic retinopathy screening program in Palestine

  • Dec 01, 2018
  • Ibnosina Journal of Medicine and Biomedical Sciences
  • Riyad Banayot
  • Research Article
  • Citations72

Trends in yield and effects of screening intervals during 17 years of a large UK community‐based diabetic retinopathy screening programme

  • Sep 25, 2009
  • Diabetic Medicine
  • A Misra +7
  • Research Article
  • Citations6

Convolutional Neural Networks Accurately Identify Ungradable Images in a Diabetic Retinopathy Telemedicine Screening Program.

  • Feb 02, 2023
  • Telemedicine and e-Health
  • John M Bryan +2
  • Research Article
  • Citations5

Addressing Technical Failures in a Diabetic Retinopathy Screening Program.

  • Feb 01, 2024
  • Clinical Ophthalmology
  • Ian Brennan +9
  • PDF
  • Research Article
  • Citations9

Enforcing artificial neural network in the early detection of diabetic retinopathy OCTA images analysed by multifractal geometry

  • Jan 01, 2020
  • Journal of Taibah University for Science
  • G El Damrawi +3
  • PDF
  • Research Article
  • Citations19

Planning an artificial intelligence diabetic retinopathy screening program: a human-centered design approach

  • Jul 07, 2023
  • Frontiers in Medicine
  • Angelica C Scanzera +8
  • Research Article
  • Citations57

Improved Automated Screening of Diabetic Retinopathy

  • Aug 25, 2011
  • Ophthalmologica
  • Carlos M Oliveira +3
  • Research Article
  • Citations76

Detection of Hard Exudates in Colour Fundus Images Using Fuzzy Support Vector Machine-Based Expert System.

  • Mar 31, 2015
  • Journal of Digital Imaging
  • T Jaya +2
  • Dissertation

Automatic analysis of retinal images to aid in the diagnosis and grading of diabetic retinopathy

  • Jan 01, 2022
  • Roberto Romero Oraa
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.