• Home
  • Search
  • Algae optical density sensor for pond monitoring and production process control
  • Cite Icon3
  • https://doi.org/10.25165/j.ijabe.20181101.2839Copy DOI Icon

Algae optical density sensor for pond monitoring and production process control

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Open raceways are one of the principal commercial-scale systems for cultivating algae to produce biofuels and bioproducts. A critical process parameter in such a system is algae cell concentration in the aqueous culture, commonly measured in terms of optical density (OD). A prototype OD sensor exclusively for real-time measurement of algae cell concentration in open ponds was designed, constructed, and tested in a laboratory scale raceway and an open-pond raceway. In the lab test, the sensor OD measurements were highly correlated with spectrometer OD measurements. The OD curve recorded by the sensor clearly showed the diurnal pattern of algae growth associated with the on-off cycle of the lighting system in the lab facility. The test data also clearly highlighted unique cultivation activities such as growth media addition and harvesting. In the open pond raceway test, sensor OD data were also highly correlated with spectrometer-measured OD even though the range of OD variation was significantly less during this test. The OD curve clearly indicated a higher biomass accumulation rate in the pond from late morning to late afternoon than during the rest of the day. These tests of the OD sensor demonstrated its potential to provide accurate real-time algae concentration data in an open pond cultivation system, the type of data that would be necessary for timely management decision-making. This sensor would also eliminate the cost associated with frequently collecting and analyzing samples, making commercial-scale algae production more economically practical. Keywords: microalgae, optical density (OD), open pond raceway, sensor, pond monitoring, circuit design, optoelectronics DOI: 10.25165/j.ijabe.20181101.2839 Citation: Yao Y, Ge Y F, Thomasson J A, Sui R X. Algae optical density sensor for pond monitoring and production process control. Int J Agric & Biol Eng, 2018; 11(1): 212–217.

Similar Papers
  • Research Article

National standards of optical density units: principles of optical scheme design, constructive and metrological characteristics

  • Jun 10, 2024
  • Izmeritel`naya Tekhnika
  • S N Marchenko
  • Research Article

Measurement of optical density in a narrow wavelength band: a method for correcting the results of indirect measurements

  • Aug 16, 2024
  • Izmeritel`naya Tekhnika
  • A V Ivanov +3
  • PDF
  • Research Article
  • Citations366

General calibration of microbial growth in microplate readers

  • Dec 01, 2016
  • Scientific Reports
  • Keiran Stevenson +4
  • Conference Article
  • Citations11

Characterization of In-Situ Fluid Responses Using Optical Fluid Analysis

  • Oct 05, 1997
  • M.M Felling +1
  • Abstract
  • Citations1

Point of Care Method for the Determination of Dabigatran in Urine Samples From Patients On Treatment.

  • Nov 16, 2012
  • Blood
  • Job Harenberg +4
  • PDF
  • Research Article
  • Citations382

Improving accuracy of cell and chromophore concentration measurements using optical density

  • Apr 22, 2013
  • BMC Biophysics
  • John A Myers +2
  • PDF
  • Research Article
  • Citations68

Multi-Wavelength Based Optical Density Sensor for Autonomous Monitoring of Microalgae

  • Sep 02, 2015
  • Sensors (Basel, Switzerland)
  • Fei Jia +2
  • Research Article
  • Citations16

Changes in polyhydroxyalkanoate granule accumulation make optical density measurement an unreliable method for estimating bacterial growth in Burkholderia thailandensis.

  • Jan 09, 2020
  • Canadian Journal of Microbiology
  • Sarah Martinez +1
  • Research Article
  • Citations20

Bioaccumulation of Cadmium in Blue Green Algae Spirulina (Arthrospira) Indica

  • Jan 01, 2012
  • Journal of Bioremediation and Biodegradation
  • Siva Kiran Rr +2
  • Research Article
  • Citations7

New bioreactor for in situ simultaneous measurement of bioluminescence and cell density

  • Feb 18, 2004
  • Review of Scientific Instruments
  • Pascal Picart +6
  • PDF
  • Research Article
  • Citations88

A comparison of conventional methods for the quantification of bacterial cells after exposure to metal oxide nanoparticles

  • Aug 21, 2014
  • BMC Microbiology
  • Hongmiao Pan +4
  • Book Chapter

Usefulness of GafChromic EBT film for dosimetry beyond 8.0 Gy

  • Jan 01, 2009
  • Hideki Aoyama +4
  • Research Article
  • Citations80

Comparison of growth of Tetraselmis in a tubular photobioreactor (Biocoil) and a raceway pond

  • Jul 24, 2013
  • Journal of Applied Phycology
  • E J Raes +4
  • Conference Article
  • Citations1

Design and research of non-contact Optical density measuring device

  • Nov 01, 2021
  • Hongbo Gao +5
  • Research Article
  • Citations2

Abstract 4300: Comparative assessment of cell viability and motility kinetics by novel real-time technology and classic endpoint assays

  • Apr 15, 2012
  • Cancer Research
  • Ridha Limame +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.