• Home
  • Search
  • An Experimental Correction Method for Relative Indentation of Normal Contact
  • Cite Icon1
  • https://doi.org/10.1017/jmech.2020.40Copy DOI Icon

An Experimental Correction Method for Relative Indentation of Normal Contact

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

ABSTRACTRelative indentation is the input signal estimating contact force model parameters, so the signal is required to have a higher precision to ensure the accuracy of the estimated contact force model parameters. However, in the impact experiment, the vibration displacements in multiple directions are often coupled in the relative indentation, resulting in a large error of the measured relative indentation. This paper presents an experimental correction method for the relative indentation. Firstly, the relative indentation is decoupled by the established model of the spatial position of the hammerhead relative to the sample to reduce the errors caused by the rotation of the pendulum boom and the vibration of the base. A pendulum impact test device is established to verify the correction method of relative indentation. The results show that the maximum relative error between the contact force estimated by using the corrected relative indentation as the input signal and the measured contact force is less than 3%. The estimated contact force is in good agreement with the measured value, and the correlation coefficient is above 0.92. It shows that the experimental correction of the relative indentation has achieved good results, which verifies the accuracy of the correction method.

Similar Papers
  • PDF
  • Research Article
  • Citations38

A learning-based tip contact force estimation method for tendon-driven continuum manipulator

  • Sep 01, 2021
  • Scientific Reports
  • Fan Feng +2
  • Research Article
  • Citations97

An investigation on the relationship between grip, push and contact forces applied to a tool handle

  • Aug 17, 2004
  • International Journal of Industrial Ergonomics
  • D Welcome +4
  • Research Article
  • Citations25

Contact force with magnetic-guided catheter ablation.

  • May 01, 2018
  • EP Europace
  • Francis Bessière +4
  • Conference Article
  • Citations7

Robotic force control by using estimated contact force

  • Dec 13, 1989
  • Han-Pang Huang +1
  • Research Article
  • Citations8

Contact force mapping and voltage thresholds during high-frequency stimulation of human cardiac ganglionated plexuses†.

  • Jan 06, 2015
  • Europace
  • R Lemery +3
  • Research Article
  • Citations9

A Novel Method for Soft Contact Sensing Based on Electrical Impedance Sensitivity Images

  • May 15, 2022
  • IEEE Sensors Journal
  • Junwei Li +1
  • Research Article
  • Citations5

A multi-asperity adhesive contact model for catheter and vascular artery contact in endovascular surgery.

  • Jan 31, 2023
  • Biomedical Microdevices
  • Yang Xu +3
  • PDF
  • Research Article
  • Citations1

An Efficient Motion Adjustment Method for a Dual-Arm Transfer Robot Based on a Two-Level Neural Network and a Greedy Algorithm

  • Aug 05, 2024
  • Electronics
  • Mengqian Chen +4
  • Research Article
  • Citations42

Body Contact Estimation of Continuum Robots With Tension-Profile Sensing of Actuation Fibers

  • Jan 01, 2024
  • IEEE Transactions on Robotics
  • Anzhu Gao +6
  • Research Article
  • Citations2

Incremental benefit of a novel signal recording system during mapping and ablation.

  • Oct 23, 2020
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
  • Deepak Padmanabhan +10
  • Research Article
  • Citations15

New Monitoring System for Wheel/Rail Contact Force without a Special Wheel-Set

  • Jan 01, 2011
  • TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
  • Hiroyuki Ohno +7
  • Conference Article

Experimental Investigation of Three-Dimensional Shroud Contact Forces in Forced-Vibration Testing of a Shrouded Blade

  • Jun 13, 2022
  • Rizwan Ahmed +2
  • PDF
  • Research Article
  • Citations9

Implementation of sensorless contact force estimation in collaborative robot based on adaptive third-order sliding mode observer

  • May 10, 2022
  • Systems Science & Control Engineering
  • Quang Dan Le +1
  • Conference Article
  • Citations9

Contact force estimation and regulation in active pantographs: An algebraic observability approach

  • Jan 01, 2007
  • A Pisano +1
  • Research Article

Contact Force Estimation of Continuum Robots without Embedded Sensors: A Review

  • Dec 26, 2025
  • Advanced Intelligent Systems
  • An Hu +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.