• Home
  • Search
  • An Experimental Study on the Seismic Response of Base-Isolated Secondary Systems
  • Cite Icon16
  • https://doi.org/10.1115/1.1445795Copy DOI Icon

An Experimental Study on the Seismic Response of Base-Isolated Secondary Systems

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The paper provides an experimental study on the feasibility of base isolation for seismic protection of nonstructural secondary system such as sensitive instrumentation, computer equipment, communication network, HVAC facilities, and power transmission systems housed in nonisolated primary structures. Damages to these secondary systems may result in significant social chaos and costly economic loss. A one-sixth-scaled three-story building model with a single-degree-of-freedom secondary system placed on its third floor is employed in this study. The secondary system is base-isolated by a laminated rubber bearing (LRB) base isolation system from the supporting floor. The ground motion input is simulated by a shaking table which generates three different types of signal including sweeping harmonic sinusoidal, the S00E component of the 1940 E1 Centro earthquake, and the simulated white noise. The experimental results demonstrate significant reduction in both displacement and acceleration responses of the secondary system by using the base isolation. Effects of parameters of the base isolation such as damping ratio and mass on its performance are also investigated. This study provides a valuable guideline for future work in this area and also verifies some previous analytical work by the authors (Hou et al., 2001). Secondary systems in a structure can be divided into two categories: structural and nonstructural. A thorough review of these types of systems and their response behavior under seismic loading has been presented by (Chen and Soong, 1988). In this paper, only nonstructural secondary systems are the subject of the study. These systems include sensitive instrumentation, computer equipment, communication network, HVAC facilities, and power transmission system that reside within a primary structure system. The huge investment made, the mission, and the critical role played by secondary systems in modern day warrant an effective protection strategy against earthquake-induced vibrations. Studies on employing base isolation techniques to protect primary structures have shown the ability of such techniques to limit dynamic response of structures in seismic disturbance (Kelley, 1986; and Ahmadi, 1988); this paper proposes the adoption of a base isolation mechanism for seismic protection of secondary systems and presents the experimental results achieved with this strategy in a scaled-down system designed without primary structural isolation. This study provides a valuable guideline for future work in this area and also verifies some previous analytical work by the authors (Ghantous, 1991; and Samaha, 1992).

Similar Papers
  • Research Article
  • Citations6

Seismic response of submerged secondary systems in base-isolated structures

  • Jun 01, 1997
  • Engineering Structures
  • Tae-Myung Shin +1
  • Research Article
  • Citations42

Seismic responses of secondary systems in base-isolated structures

  • Jan 01, 1992
  • Engineering Structures
  • Fa-Gung Fan +1
  • Research Article
  • Citations3

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Apr 01, 2019
  • Earthquakes and Structures
  • Pardeep Kumar +1
  • Research Article
  • Citations7

Stability of laminated rubber bearing and its application to seismic isolation

  • Aug 01, 1999
  • KSME International Journal
  • Gyeong-Hoi Koo +3
  • Research Article
  • Citations1

Horizontal Denture: A Prosthodontic Alternative for Severe Maxillary Atrophy

  • Jan 08, 2014
  • Journal of Oral Implantology
  • David Peñarrocha-Oltra +5
  • Research Article
  • Citations7

An engineering approach for evaluating the dynamic response of acceleration‐sensitive secondary systems in flexible structures

  • Feb 16, 2021
  • Earthquake Engineering & Structural Dynamics
  • Stylianos I Pardalopoulos +1
  • Research Article

Hysteresis Loops of Base Isolation System - An Overview

  • Mar 01, 2021
  • Key Engineering Materials
  • M.A Amir +1
  • Research Article

LARSA 2000: Seismic Analysis of Bridges with Seismic Isolation and Energy Dissipation Devices

  • Jan 01, 2000
  • Transportation Research Record: Journal of the Transportation Research Board
  • Panos Tsopelas +1
  • Research Article
  • Citations59

Nonlinear dynamic analysis for multi-storey RC structures with hybrid base isolation systems in presence of bi-directional ground motions

  • Jul 22, 2016
  • Composite Structures
  • Donato Cancellara +1
  • Research Article
  • Citations258

Development and characterization of a magnetorheological elastomer based adaptive seismic isolator

  • Jan 31, 2013
  • Smart Materials and Structures
  • Yancheng Li +3
  • Conference Article

Dynamic Analysis of a Smart Base-Isolation System Based on MR Elastomers

  • Jan 01, 2010
  • Hyung-Jo Jung +2
  • Research Article
  • Citations27

Stochastic prediction of maximum seismic response of light secondary systems

  • Dec 01, 1974
  • Nuclear Engineering and Design
  • A.K Singh +1
  • Research Article
  • Citations5

Variations of horizontal stiffness of laminated rubber bearings using new boundary conditions

  • Jul 31, 2011
  • Scientific Research and Essays
  • Ali Karbakhsh +3
  • Book Chapter
  • Citations2

Seismic Control of Soft Storey Buildings Using LRB Isolation System

  • Jul 03, 2020
  • Soumitri Soumyarani Choudhury +1
  • Research Article
  • Citations21

Shaking table test of space double-layer cylindrical reticulated shell with three-dimensional isolation bearing

  • Dec 22, 2021
  • Journal of Constructional Steel Research
  • Gui-Bo Nie +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.