• Home
  • Search
  • Analysis of Artifacts in Subpixel Remote Sensing Image Registration
  • Open Access IconOpen Access
  • Cite Icon103
  • https://doi.org/10.1109/tgrs.2006.882262Copy DOI Icon

Analysis of Artifacts in Subpixel Remote Sensing Image Registration

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Subpixel accuracy image registration is needed for applications such as digital elevation model extraction, change detection, pan-sharpening, and data fusion. In order to achieve this accuracy, the deformation between the two images to be registered is usually modeled by a displacement vector field which can be estimated by measuring rigid local shifts for each pixel in the image. In order to measure subpixel shifts, one uses image resampling. Sampling theory says that, if a continuous signal has been sampled according to the Nyquist criterion, a perfect continuous reconstruction can be obtained from the sampled version. Therefore, a shifted version of a sampled signal can be obtained by interpolation and resampling with a shifted origin. Since only a sampled version of the shifted signal is needed, the reconstruction needs only to be performed for the new positions of the samples, so the whole procedure comes to computing the value of the signal for the new sample positions. In the case of image registration, the similarity between the reference image and the shifted versions of the image to be registered is measured, assuming that the maximum of similarity determines the most likely shift. The image interpolation step is thus performed a high number of times during the similarity optimization procedure. In order to reduce the computation cost, approximate interpolations are performed. Approximate interpolators will introduce errors in the resampled image which may induce errors in the similarity measure and therefore produce errors in the estimated shifts. In this paper, it is shown that the interpolation has a smoothing effect which depends of the applied shift. This means that, in the case of noisy images, the interpolation has a denoising effect, and therefore, it increases the quality of the similarity estimation. Since this blurring is not the same for every shift, the similarity may be low for a null shift (no blurring) and higher for shifts close to half a pixel (strong blurring). This paper presents an analysis of the behavior of the different interpolators and their effects on the similarity measures. This analysis will be done for the two similarity measures: the correlation coefficient and the mutual information. Finally, a strategy to attenuate the interpolation artifacts is proposed

Similar Papers
  • Research Article

SU‐E‐J‐85: Landmark‐Driven Interactive Deformable Image Registration

  • Jun 01, 2013
  • Medical Physics
  • N Shusharina +2
  • Research Article
  • Citations24

Sparse‐induced similarity measure: mono‐modal image registration via sparse‐induced similarity measure

  • Dec 01, 2014
  • IET Image Processing
  • Aboozar Ghaffari +1
  • Research Article
  • Citations23

A method to map errors in the deformable registration of 4DCT images.

  • Oct 14, 2010
  • Medical Physics
  • Constantin Vaman +3
  • Conference Article
  • Citations2

Image Registration Using Template Matching and Similarity Measures for Dental Radiograph

  • Nov 01, 2012
  • Maryam Norollah +2
  • Conference Article
  • Citations5

Edgeworth-based approximation of Mutual Information for medical image registration

  • Jul 01, 2010
  • Mathieu Rubeaux +3
  • Research Article
  • Citations43

A LAGRANGIAN GAUSS-NEWTON-KRYLOV SOLVER FOR MASS- AND INTENSITY-PRESERVING DIFFEOMORPHIC IMAGE REGISTRATION.

  • Jan 01, 2017
  • SIAM Journal on Scientific Computing
  • Andreas Mang +1
  • Conference Article
  • Citations8

An automatic registration framework using quantum particle swarm optimization for remote sensing images

  • Jan 01, 2007
  • Yang Lu +2
  • Research Article
  • Citations11

An iterative point correspondence algorithm for automatic image registration: An application to dental subtraction radiography

  • Aug 29, 2008
  • Computer Methods and Programs in Biomedicine
  • Vasiliki E Markaki +2
  • Research Article
  • Citations25

Image Registration Based on Low Rank Matrix: Rank-Regularized SSD

  • Aug 25, 2017
  • IEEE Transactions on Medical Imaging
  • Aboozar Ghaffari +1
  • Research Article
  • Citations1

SU-E-J-126: Generation of Fluoroscopic 3D Images Using Single X-Ray Projections on Realistic Modified XCAT Phantom Data.

  • Jun 01, 2012
  • Medical physics
  • P Mishra +6
  • Supplementary Content
  • Citations2

Retracted: Reducing motion artifacts in 4D MR images using principal component analysis (PCA) combined with linear polynomial fitting model.

  • Mar 01, 2015
  • Journal of Applied Clinical Medical Physics
  • Juan Yang +3
  • Research Article
  • Citations11

Selection of a Similarity Measure Combination for a Wide Range of Multimodal Image Registration Cases

  • May 20, 2020
  • IEEE Transactions on Geoscience and Remote Sensing
  • Mikhail L Uss +3
  • Conference Article
  • Citations11

An improved mutual information similarity measure for registration of multi-modal remote sensing images

  • Oct 15, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Maha Shadaydeh +1
  • Research Article
  • Citations2

Optimized image registration algorithm at subpixel level for Geostationary Operational Environmental Satellite-R Advanced Baseline Imager navigation and registration performance assessment

  • May 02, 2023
  • Journal of Applied Remote Sensing
  • Zhenping Li
  • Conference Article
  • Citations4

Image registration of medical images

  • Apr 01, 2017
  • Sehrish Jamil +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.