Anatomisch adaptierte Variation des Röhrenstroms bei der CT

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To assess the impact of a method for anatomically adapted tube current variation. The resulting CT image quality was evaluated quantitatively and qualitatively. CT scans of 100 patients were performed with a constant tube current (Group 1) and another 100 patients with an anatomically adapted tube current (Group 2). The CT tube current was varied during a 360 degrees tube rotation reflecting the measured density values extracted from two perpendicular scout views. The standard deviation of densities of defined regions was measured. The image quality was ranked (1 = non-diagnostic-5 = excellent) by three radiologists. The effective tube current could be reduced by an average of 8.9% (0-20.4%). The mean tube current reduction depended on the body region: pelvis (13.2%), abdomen (8.4%) and thorax (3.3%). The image quality was not significantly reduced in Group 2. The method for anatomically adapted tube current variation leads especially in the pelvis to a significant mAs reduction without considerable loss of image quality.

Similar Papers
  • Research Article
  • Citations4

Potential of dosage reduction of cone-beam CT dacryocystography in healthy volunteers by decreasing tube current.

  • Oct 27, 2020
  • Japanese journal of radiology
  • Zhaoyue Chen +3
  • Research Article
  • Citations97

Urinary Stone Disease: Comparison of Standard-Dose and Low-Dose with 4D MDCT Tube Current Modulation

  • Feb 01, 2007
  • American Journal of Roentgenology
  • Tom H Mulkens +6
  • Research Article
  • Citations157

Circle of Willis at CT Angiography: Dose Reduction and Image Quality—Reducing Tube Voltage and Increasing Tube Current Settings

  • Jan 17, 2007
  • Radiology
  • Annet Waaijer +5
  • PDF
  • Research Article
  • Citations2

CT of the medial clavicular epiphysis for forensic age estimation – raised arms position recommended

  • Jan 01, 2025
  • International Journal of Legal Medicine
  • Saskia C Kuhnen +8
  • Research Article
  • Citations95

Radiation dose reduction in chest CT—Review of available options

  • Jul 08, 2014
  • European Journal of Radiology
  • Takeshi Kubo +3
  • Research Article
  • Citations298

Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.

  • Sep 09, 2004
  • Radiology
  • Marilyn J Siegel +4
  • Research Article
  • Citations35

Computed tomography in trauma patients using iterative reconstruction: reducing radiation exposure without loss of image quality.

  • Apr 06, 2015
  • Acta Radiologica
  • Johannes Kahn +5
  • Research Article

SU‐E‐I‐25: Determining Tube Current, Tube Voltage and Pitch Suitable for Low‐ Dose Lung Screening CT

  • May 29, 2014
  • Medical Physics
  • K Williams +1
  • Research Article
  • Citations1

TH‐A‐214‐10: Comparison of Bismuth Shielding and Globally Reducing Tube Current in Head and Thoracic CT

  • Jun 01, 2011
  • Medical Physics
  • J Wang +5
  • Research Article

Comparative study of the findings in thick dense breasts based on two target-filters in digital mammography: a phantom study

  • Jan 25, 2018
  • Zhonghua fangshe yixue yu fanghu zazhi
  • Xiao Chen +3
  • Research Article
  • Citations24

Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT in patients with normal body mass indices: effect of tube voltage, tube current, and iodine concentration on image quality and radiation dose.

  • Aug 26, 2014
  • The international journal of cardiovascular imaging
  • Sung Mok Kim +2
  • Research Article
  • Citations5

Radiation dose and image quality in intraoperative CT (iCT) angiography of the brain with stereotactic head frames.

  • Jan 11, 2019
  • European Radiology
  • Robert Forbrig +10
  • Research Article
  • Citations6

Compressed sensing for reduced hardware footprint in medical ultrasound

  • Jul 04, 2020
  • Ultrasonics
  • Jovan Mitrovic +4
  • Conference Article
  • Citations2

A method for optimization of the x-ray tube current in ROI imaging using a simulation framework for radiation dose and image quality calculation for arbitrary fluence distributions

  • Feb 15, 2021
  • Sascha Manuel Huck +3
  • PDF
  • Research Article
  • Citations5

Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study

  • Sep 25, 2020
  • Radiation Oncology
  • Jihun Kim +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.