Aqueous humor dynamics with a passive valve glaucoma drainage device post-implantation

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Glaucoma, an irreversible ocular disease with a risk of blindness, is often treated with glaucoma drainage device (GDD) implantation as a last resort. The study on the impact of passive valve GDD implantation on aqueous humor (AH) dynamics is of great significance for supplementing numerical simulation methods for GDDs and exploring novel glaucoma treatment approaches. Therefore, this study employed a porous region method to simulate the regulatory role of the trabecular meshwork in intraocular pressure (IOP), establishing a glaucoma model. Based on this, a multi-outlet, passive valve GDD was designed and virtually implanted, with the post-implantation flow field simulated using mesh deformation, overset mesh, and fluid–structure interaction methods. Results indicate that by adjusting the structural parameters of the GDD, IOP can be maintained within an acceptable range. The thickness (h) of the upper component has a more significant impact on the IOP and outlet flow distribution ratio than the distance (d) between the drainage tube's central axis and the drainage groove. Both increases in h and d lead to increased IOP, gradually approaching pre-implantation levels. The fissure region formed by the deformation of the upper component and the trabecular meshwork region work together to regulate IOP in the simulation. However, the fissure region shows a greater height near the center of the shunting tube, potentially imposing additional mechanical stress on ocular tissues, reaching up to 5.8 μm for a GDD with h = 10 and d = 160 μm. Additionally, wall shear stress on the iris near the shunting tube inlet is relatively high, reaching values of 6.24 × 10−4 Pa under the same conditions. In conclusion, the designed GDD effectively controls postoperative IOP. Studying AH regulation performance after GDD implantation provides a foundation for the personalized customization of passive valve-type GDDs.

Similar Papers
  • Front Matter
  • Citations11

The Boston Keratoprosthesis: Highs and Lows of Intraocular Pressure and Outcomes

  • Dec 16, 2016
  • Ophthalmology
  • Keith H Baratz +1
  • Research Article
  • Citations37

Implantation of Second Glaucoma Drainage Devices After Failure of Primary Devices

  • Jan 01, 2002
  • Ophthalmic Surgery, Lasers and Imaging Retina
  • David G Godfrey +5
  • Research Article
  • Citations22

Outcomes of Trabeculectomy and Glaucoma Drainage Devices for Elevated Intraocular Pressure After Penetrating Keratoplasty.

  • Mar 28, 2018
  • Cornea
  • Mehmet Yakin +9
  • Research Article
  • Citations3

A New Design and Application of Bioelastomers for Better Control of Intraocular Pressure in a Glaucoma Drainage Device

  • Jul 09, 2013
  • Advanced Healthcare Materials
  • Quang Minh Luong +6
  • Research Article

Combined Virna Glaucoma Implant (VGI) Implantation and Pars Plana Vitrectomy for Refractory Aphakic Glaucoma

  • Feb 12, 2024
  • Ophthalmologica Indonesiana
  • Felicia Sesih Herdian +5
  • Research Article
  • Citations30

Lentiviral Vector-Mediated Expression of Exoenzyme C3 Transferase Lowers Intraocular Pressure in Monkeys.

  • May 09, 2019
  • Molecular Therapy
  • Junkai Tan +8
  • Research Article
  • Citations4

Morphology of glaucoma drainage implantation.

  • Apr 01, 1997
  • Current opinion in ophthalmology
  • Jörg P.E Stürmer
  • PDF
  • Research Article
  • Citations24

The Effect of Intraocular Pressure Load Boundary on the Biomechanics of the Human Conventional Aqueous Outflow Pathway

  • Nov 10, 2022
  • Bioengineering
  • Alireza Karimi +7
  • Research Article
  • Citations6

36-Month Outcomes of Ahmed ClearPath® Glaucoma Drainage Device in Severe Primary Open Angle Glaucoma.

  • Jun 01, 2024
  • Clinical ophthalmology (Auckland, N.Z.)
  • Nithya Boopathiraj +7
  • Research Article
  • Citations11

Ultrasound evaluation of glaucoma drainage devices in children

  • Apr 21, 2015
  • Journal of American Association for Pediatric Ophthalmology and Strabismus
  • Nafees B Baig +2
  • Research Article
  • Citations7

Simultaneous pars plana vitrectomy and glaucoma drainage device implant

  • Jan 01, 2010
  • Archivos de la Sociedad Española de Oftalmología (English Ed)
  • M.J Suárez-Fernández +4
  • Research Article
  • Citations25

Glaucoma Drainage Device Coated with Mitomycin C Loaded Opal Shale Microparticles to Inhibit Bleb Fibrosis.

  • Jan 28, 2019
  • ACS Applied Materials & Interfaces
  • Aimeng Dong +5
  • PDF
  • Research Article
  • Citations1

Risk factors for receiving both scleral buckle and glaucoma drainage device in children

  • Oct 25, 2024
  • Scientific Reports
  • Mariana Abi Karam +6
  • Discussion

Re: Pakravan et al.: Effect of early treatment with aqueous suppressants on Ahmed glaucoma valve implantation outcomes (Ophthalmology 2014;121:1693-8)

  • Nov 24, 2014
  • Ophthalmology
  • Simon K Law +1
  • Research Article
  • Citations20

Effectiveness of Trabeculectomy and Tube Shunt with versus without Concurrent Phacoemulsification: Intelligent Research in Sight Registry Longitudinal Analysis

  • Jul 14, 2022
  • Ophthalmology Glaucoma
  • Elizabeth C Ciociola +15
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.