• Home
  • Search
  • Artifact-robust diffusion-weighted whole-body imaging with background suppression at 3 T using improved turbo spin-echo diffusion-weighted imaging.
  • Cite Icon5
  • https://doi.org/10.1259/bjr.20180489Copy DOI Icon

Artifact-robust diffusion-weighted whole-body imaging with background suppression at 3 T using improved turbo spin-echo diffusion-weighted imaging.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To compare single-shot turbo spin-echo (TSE) diffusion-weighted whole-body imaging with background suppression (DWIBS) and echo-planar imaging (EPI) DWIBS to determine the feasibility of direct-coronal TSE-DWIBS. All measurements were performed using a 3.0 T MRI scanner. In the phantom study, we compared the contrast ratios (CRs) of tumor-mimicking phantom (tumor) to muscle-mimicking phantom (muscle) and water to muscle and the signal-to-noise ratio (SNR) between TSE-DWIBS and EPI-DWIBS. In the volunteer study, 10 healthy volunteers were whole-body scanned with direct-coronal TSE-DWIBS, direct-coronal EPI-DWIBS (corEPI-DWIBS), and transverse EPI-DWIBS (traEPI-DWIBS). Two radiologists assessed the image distortion, uniformity of fat suppression, overall artifacts, and overall image quality in maximum intensity projection (MIP) images from each DWIBS image using a 5-point scale. In the phantom study, the CR of tumor to muscle was found to be lower for TSE-DWIBS (10.57 ± 0.45) than for EPI-DWIBS (15.38 ± 0.27), and the CR of water to muscle was higher for TSE-DWIBS (9.61 ± 0.66) than for EPI-DWIBS (2.52 ± 0.60). The volunteer study revealed good inter observer agreement between TSE-DWIBS and EPI-DWIBS with respect to image distortion, uniformity of fat suppression, overall artifacts, and overall image quality, with weighted Cohen's κ coefficients of 0.91, 0.74, 0.87, and 0.72, respectively. Qualitative analysis scores for image distortion, uniformity of fat suppression, overall artifacts, and overall image quality were significantly higher for TSE-DWIBS than for corEPI-DWIBS or traEPI-DWIBS (p < 0.05). Direct-coronal TSE-DWIBS is robust against magnetic field inhomogeneity. High-quality images without distortion or fat suppression inhomogeneity were obtained. Many studies on DWIBS have been previously reported; however, these studies used EPI read-out. To the best of our knowledge, no studies using TSE read-out have been reported. In this study, we examined the feasibility of TSE-DWIBS with lesser artifacts than EPI-DWIBS.

Similar Papers
  • Research Article
  • Citations14

Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T.

  • Feb 06, 2017
  • Acta Radiologica
  • Amber L Pokorney +4
  • Research Article
  • Citations38

Abdominal MRI at 3.0 T: LAVA‐flex compared with conventional fat suppression T1‐weighted images

  • Nov 12, 2013
  • Journal of Magnetic Resonance Imaging
  • Xing Hui Li +7
  • Research Article
  • Citations3

The shoulder.

  • Apr 01, 2015
  • Topics in magnetic resonance imaging : TMRI
  • Nancy Major +2
  • Research Article
  • Citations12

MR Imaging of the Spine at 3.0T with T2-Weighted IDEAL Fast Recovery Fast Spin-Echo Technique

  • Dec 23, 2011
  • Korean Journal of Radiology
  • Ai-Jun Ren +4
  • Research Article
  • Citations120

Diffuse lung disease: assessment with helical CT--preliminary observations of the role of maximum and minimum intensity projection images.

  • Aug 01, 1996
  • Radiology
  • M Bhalla +5
  • PDF
  • Research Article
  • Citations3

Comparison of the dose on specific 3DCT images and the accumulated dose for cardiac structures in esophageal tumors radiotherapy: whether specific 3DCT images can be used for dose assessment?

  • Dec 01, 2019
  • Radiation Oncology
  • Ying Tong +3
  • Research Article
  • Citations8

Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla

  • Apr 12, 2017
  • Zeitschrift für Medizinische Physik
  • Fabian Hilbert +5
  • Research Article
  • Citations8

Assessment of the Quality of Breast MR Imaging Using the Modified Dixon Method and Frequency-selective Fat Suppression: A Phantom Study

  • Jan 01, 2018
  • Magnetic Resonance in Medical Sciences
  • Yasuo Takatsu +5
  • Research Article
  • Citations44

Comparison of multishot turbo spin echo and HASTE sequences for T2-weighted MRI of liver lesions.

  • Sep 01, 1998
  • Journal of Magnetic Resonance Imaging
  • Jeong‐Sik Yu +4
  • PDF
  • Abstract
  • Citations1

High intensity signal on MIP images from routine TOF-MRA of carotid atherosclerotic plaque indicates higher volume of intraplaque hemorrhage and lipid rich necrotic core

  • Feb 01, 2012
  • Journal of Cardiovascular Magnetic Resonance
  • Kiyofumi Yamada +11
  • Research Article

Evaluation of Image Quality of Temporal Maximum Intensity Projection and Average Intensity Projection of Adaptive 4D-Spiral CT Scans: A Phantom Study.

  • Apr 07, 2025
  • Cureus
  • Hiroki Horinouchi +6
  • Research Article
  • Citations7

Contrast-Enhanced T1-Weighted Head and Neck MRI: Prospective Intraindividual Image Quality Comparison of Spiral GRE, Cartesian GRE, and Cartesian TSE Sequences.

  • Nov 17, 2021
  • American Journal of Roentgenology
  • Elisabeth Sartoretti +8
  • Research Article
  • Citations10

Maximum intensity projection (MIP) imaging using slice‐stacking MRIa)

  • Oct 20, 2010
  • Medical Physics
  • Justus Adamson +4
  • Research Article
  • Citations8

Whole‐heart chemical shift encoded water–fat MRI

  • Nov 01, 2013
  • Magnetic Resonance in Medicine
  • Valentina Taviani +8
  • Research Article
  • Citations33

Application of time‐resolved angiography with stochastic trajectories (twist)‐dixon in dynamic contrast‐enhanced (dce) breast mri

  • Sep 05, 2013
  • Journal of Magnetic Resonance Imaging
  • Yuan Le +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.