Automatic quality control of brain 3D FLAIR MRIs for a clinical data warehouse.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Clinical data warehouses, which have arisen over the last decade, bring together the medical data of millions of patients and offer the potential to train and validate machine learning models in real-world scenarios. The quality of MRIs collected in clinical data warehouses differs significantly from that generally observed in research datasets, reflecting the variability inherent to clinical practice. Consequently, the use of clinical data requires the implementation of robust quality control tools. By using a substantial number of pre-existing manually labelled T1-weighted MR images (5,500) alongside a smaller set of newly labelled FLAIR images (926), we present a novel semi-supervised adversarial domain adaptation architecture designed to exploit shared representations between MRI sequences thanks to a shared feature extractor, while taking into account the specificities of the FLAIR thanks to a specific classification head for each sequence. This architecture thus consists of a common invariant feature extractor, a domain classifier and two classification heads specific to the source and target, all designed to effectively deal with potential class distribution shifts between the source and target data classes. The primary objectives of this paper were: (1) to identify images which are not proper 3D FLAIR brain MRIs; (2) to rate the overall image quality. For the first objective, our approach demonstrated excellent results, with a balanced accuracy of 89%, comparable to that of human raters. For the second objective, our approach achieved good performance, although lower than that of human raters. Nevertheless, the automatic approach accurately identified bad quality images (balanced accuracy >79%). In conclusion, our proposed approach overcomes the initial barrier of heterogeneous image quality in clinical data warehouses, thereby facilitating the development of new research using clinical routine 3D FLAIR brain images.

Similar Papers
  • Research Article
  • Citations45

Automatic quality control of brain T1-weighted magnetic resonance images for a clinical data warehouse.

  • Jan 01, 2022
  • Medical Image Analysis
  • Simona Bottani +6
  • Research Article
  • Citations2

Automated MRI Quality Assessment of Brain T1-weighted MRI in Clinical Data Warehouses: A Transfer Learning Approach Relying on Artefact Simulation

  • Jun 14, 2024
  • Machine Learning for Biomedical Imaging
  • Sophie Loizillon +8
  • Research Article
  • Citations16

Automatic motion artefact detection in brain T1-weighted magnetic resonance images from a clinical data warehouse using synthetic data

  • Dec 23, 2023
  • Medical Image Analysis
  • Sophie Loizillon +6
  • Conference Article
  • Citations6

Transfer learning from synthetic to routine clinical data for motion artefact detection in brain T1-weighted MRI

  • Apr 03, 2023
  • Sophie Loizillon +6
  • PDF
  • Conference Article
  • Citations1

Leveraging noise and contrast simulation for the automatic quality control of routine clinical T1-weighted brain MRI

  • Apr 02, 2024
  • Sophie Loizillon +8
  • Research Article
  • Citations18

Evaluation of MRI-based machine learning approaches for computer-aided diagnosis of dementia in a clinical data warehouse.

  • Oct 01, 2023
  • Medical Image Analysis
  • Simona Bottani +6
  • Research Article
  • Citations38

Magnetic Resonance Imaging of the Brain Using Compressed Sensing- Quality Assessment in Daily Clinical Routine.

  • May 16, 2019
  • Clinical Neuroradiology
  • Sebastian Mönch +5
  • Research Article
  • Citations14

Detection of Cortical and Deep Gray Matter Lesions in Multiple Sclerosis Using DIR and FLAIR at 3T.

  • Dec 22, 2020
  • Journal of Neuroimaging
  • Charlie C Park +7
  • Research Article
  • Citations14

Pre- and post-contrast three-dimensional double inversion-recovery MRI in human glioblastoma

  • Apr 01, 2013
  • Journal of Neuro-Oncology
  • Robert J Harris +10
  • PDF
  • Supplementary Content
  • Citations23

Good practices for clinical data warehouse implementation: A case study in France

  • Jul 06, 2023
  • PLOS Digital Health
  • Matthieu Doutreligne +4
  • PDF
  • Research Article
  • Citations23

Comparative study between double inversion recovery (DIR) and fluid-attenuated inversion recovery (FLAIR) MRI sequences for detection of cerebral lesions in multiple sclerosis

  • Sep 15, 2020
  • Egyptian Journal of Radiology and Nuclear Medicine
  • Shaima Fattouh Elkholy +3
  • Research Article
  • Citations1

Comparison of Double Inversion Recovery and FLAIR Sequences in Diagnosing Multiple Sclerosis Infratentorial Plaques

  • Jan 01, 2018
  • NeuroQuantology
  • Gulhan Ertan +1
  • Research Article
  • Citations7

MR Imaging in Multiple Sclerosis: The Accuracy of 3D Double Inversion Recovery at 3 Tesla and the Potential for Single Sequence Imaging

  • Feb 01, 2011
  • The Neuroradiology Journal
  • S.R Khangure +1
  • Research Article
  • Citations7

Diagnostic Accuracy and Correlation between Double Inversion Recovery (DIR), FLAIR and T2W Imaging Sequences with EDSS in Detection of Lesions at different Anatomical Regions in MS Patients

  • Dec 31, 2020
  • NeuroQuantology
  • Abdullah Dhaifallah Almutairi +7
  • Research Article

The added value of double inversion recovery (DIR) sequence compared to fluid attenuation inversion recovery (FLAIR) in identifying multiple sclerosis lesions and different cortical subtypes

  • Dec 31, 2023
  • Romanian Journal of Neurology
  • Mohamed Mohamed Anwar Mohamed +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.