The variable refrigerant flow system is one of the best heating, ventilation, and air conditioning systems (HVAC) thanks to its ability to provide thermal comfort inside buildings. But, at the same time, these systems are considered one of the most energy-consuming systems in the building sector. Thus, it is crucial to well size the system according to the building’s cooling and heating needs and the indoor temperature fluctuations. Although many researchers have studied the optimization of the building energy performance considering heating or cooling needs, using air handling units, radiant floor heating, and direct expansion valves, few studies have considered the use of multi-objective optimization using only the thermostat setpoints of VRF systems for both cooling and heating needs. Thus, the main aim of this study is to conduct a sensitivity analysis and a multi-objective optimization strategy for a residential building containing a variable refrigerant flow system, to evaluate the effect of the building performance on energy consumption and improve the building energy efficiency. The numerical model was based on the EnergyPlus, jEPlus, and jEPlus+EA simulation engines. The approach used in this paper has allowed us to reach significant quantitative energy saving by varying the cooling and heating setpoints and scheduling scenarios. It should be stressed that this approach could be applied to several HVAC systems to reduce energy-building consumption.

Loading PDF

Similar Papers
  • Research Article
  • Citations3

Optimizing Energy Efficiency and Sustainability in Winter Climate Control: Innovative Use of Variable Refrigerant Flow (VRF) Systems in University Buildings

  • Feb 23, 2025
  • Applied Sciences
  • Yolanda Arroyo Gómez +5
  • Research Article
  • Citations8

Comparison study of a novel solid desiccant heat pump system with EnergyPlus

  • Mar 07, 2014
  • Building Simulation
  • Yu Jiang +2
  • Research Article
  • Citations38

A novel variable refrigerant flow system with solar regeneration-based desiccant-assisted ventilation

  • Apr 20, 2022
  • Solar Energy
  • Gaurav Singh +1
  • PDF
  • Research Article
  • Citations7

Comparison between Variable and Constant Refrigerant Flow Air Conditioning Systems in Arid Climate: Life Cycle Cost Analysis and Energy Savings

  • Sep 17, 2021
  • Sustainability
  • Georges Atallah +1
  • Research Article
  • Citations184

Variable refrigerant flow systems: A review

  • Feb 10, 2010
  • Energy and Buildings
  • Tolga N Aynur
  • Research Article

VRF noise: From data sheets to field measurements

  • Oct 01, 2021
  • The Journal of the Acoustical Society of America
  • Tyler Tracy
  • Conference Article
  • Citations1

Modeling and Calibration of a Variable Refrigerant Flow (VRF) System with a Dedicated Outdoor Air System (DOAS)

  • Aug 07, 2017
  • Dongsu Kim +2
  • Research Article
  • Citations41

Model calibration of a variable refrigerant flow system with a dedicated outdoor air system: A case study

  • Oct 16, 2017
  • Energy and Buildings
  • Dongsu Kim +3
  • Research Article
  • Citations95

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

  • Nov 12, 2009
  • Energy and Buildings
  • Xiaobing Liu +1
  • Research Article
  • Citations5

Energy consumption analysis and operating characteristics research on small time scale of variable refrigerant flow air conditioning systems in public buildings

  • Sep 28, 2024
  • Thermal Science and Engineering Progress
  • Junting Li +5
  • Research Article

Numerical study on performance comparison for sub-cooling methods using a sub-cooler in a multi-split variable refrigerant flow (VRF) system.

  • Aug 24, 2019
  • Institut International du Froid
  • T Lee +2
  • Research Article
  • Citations81

Experimental investigation on a novel temperature and humidity independent control air conditioning system – Part I: Cooling condition

  • Aug 20, 2014
  • Applied Thermal Engineering
  • Y Jiang +3
  • Research Article
  • Citations27

Determination of the economical optimum insulation thickness for VRF (variable refrigerant flow) systems

  • Jul 02, 2015
  • Energy
  • Abdullah Yildiz +1
  • Research Article
  • Citations5

Power-controllable variable refrigerant flow system with flexibility value for demand response

  • Nov 22, 2024
  • Energy
  • Peng Ren +2
  • Research Article

The temperature control of chilled water for the central air conditioning systems.

  • Aug 16, 2015
  • Institut International du Froid
  • Ming-Huei Chu +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.