• Home
  • Search
  • Cardiac motion and spillover correction for quantitative PET imaging using dynamic MRI.
  • Cite Icon6
  • https://doi.org/10.1002/mp.13345Copy DOI Icon

Cardiac motion and spillover correction for quantitative PET imaging using dynamic MRI.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Cardiac positron emission tomography/magnetic resonance imaging (PET/MRI) acquisition presents novel clinical applications thanks to the combination of viability and metabolic imaging (PET) and functional and structural imaging (MRI). However, the resolution of PET, as well as cardiac and respiratory motion in nongated cardiac imaging acquisition protocols, leads to a reduction in image quality and severe quantitative bias. Respiratory or cardiac motion is customarily addressed with gated reconstruction which results in higher noise. Inspired by a method that has been used in brain PET, a practical correction approach, designed to overcome these existing limitations for quantitative PET imaging, was developed and applied in the context of cardiac PET/MRI. The correction approach for PET data consists of computing the mean density map of each underlying moving region, as obtained with MRI, and translating them to the PET space taking into account the PET spatial and temporal resolution. Using these tissue density maps, the method then constructs a system of linear equations that models the activity recovery and cross-contamination coefficients, which can be solved for the true activity values. Physical and numerical cardiac phantoms were employed in order to quantify the proposed correction. The full correction pipeline was then used to assess differences in metabolic function between scar and healthy myocardium in eight patients with recent acute myocardial infarction using [11 C]-acetate. Data from ten additional patients, injected with [18 F]-FDG, were used to compare the method to the standard electrocardiography (ECG)-gated approach. The proposed method resulted in better recovery (from 32% to 95% on the simulated phantom model) and less residual activity than the standard approach. Higher signal-to-noise and contrast-to-noise ratios than ECG-gating were also witnessed (Signal-to-noise ratio (SNR) increased from 2.92 to 5.24, contrast-to-noise ratio (CNR) increased from 62.9 to 145.9 when compared to a four-gate reconstruction). Finally, the relevance of this correction using [11 C]-acetate PET patient data, for which erroneous physiological conclusions could have been made based on the uncorrected data, was established as the correction led to the expected clinical results. An efficient and simple method to correct for the quantitative biases in PET measurements caused by cardiac motion has been developed. Validation experiments using phantom and patient data showed improved accuracy and reliability with this approach when compared to simpler strategies such as gated acquisition or optimal regions of interest (ROI).

Similar Papers
  • PDF
  • Research Article
  • Citations27

Characterization of Respiratory and Cardiac Motion from Electro-Anatomical Mapping Data for Improved Fusion of MRI to Left Ventricular Electrograms

  • Nov 08, 2013
  • PLoS ONE
  • Sébastien Roujol +3
  • Abstract

Cardiac stereotactic body radiation therapy for refractory ventricular tachycardia: Impact of cardiac and respiratory movement on the target volume definition

  • Jan 01, 2021
  • Archives of Cardiovascular Diseases Supplements
  • J Bellec +8
  • Research Article
  • Citations3

Development and first implementation of a novel multi-modality cardiac motion and dosimetry phantom for radiotherapy applications.

  • Jul 23, 2024
  • Medical physics
  • Kenneth W Gregg +9
  • Book Chapter
  • Citations5

Motion Estimation Model for Cardiac and Respiratory Motion Compensation

  • Jan 01, 2012
  • Sebastian Kaeppler +8
  • Research Article
  • Citations9

Self-gated cardiac cine imaging using phase information.

  • Mar 22, 2016
  • Magnetic Resonance in Medicine
  • Hyunseok Seo +3
  • Research Article
  • Citations40

Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET

  • Dec 01, 2015
  • Physics in Medicine & Biology
  • Tao Feng +3
  • Research Article
  • Citations7

A model for gastrointestinal tract motility in a 4D imaging phantom of human anatomy.

  • Feb 25, 2023
  • Medical Physics
  • Ergys Subashi +4
  • Research Article
  • Citations23

Consistency-based respiratory motion estimation in rotational angiography.

  • Sep 01, 2017
  • Medical Physics
  • Mathias Unberath +3
  • PDF
  • Abstract
  • Citations5

Towards cardiac and respiratory motion characterization from electrophysiology data for improved real time MR-integration

  • Jan 01, 2013
  • Journal of Cardiovascular Magnetic Resonance
  • Sébastien Roujol +4
  • Research Article
  • Citations31

Effects of Intrafractional Motion on Water Equivalent Pathlength in Respiratory-Gated Heavy Charged Particle Beam Radiotherapy

  • Aug 16, 2007
  • International Journal of Radiation Oncology*Biology*Physics
  • Shinichiro Mori +2
  • Conference Article
  • Citations6

Motion Displacement Field Estimation using Time-of-Flight PET Histoimages

  • Oct 01, 2019
  • Yusheng Li +2
  • Research Article
  • Citations49

Model‐based reconstruction for cardiac cine MRI without ECG or breath holding

  • Apr 23, 2010
  • Magnetic Resonance in Medicine
  • Freddy Odille +5
  • Abstract
  • Citations1

Image Guided, Motion-free Patient Body Setup using 3D Volumetric Image Registration of Classified Stable Bony Landmarks

  • Aug 20, 2008
  • International Journal of Radiation Oncology*Biology*Physics
  • G Li +9
  • Research Article
  • Citations672

XD-GRASP: Golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing.

  • Mar 25, 2015
  • Magnetic Resonance in Medicine
  • Li Feng +5
  • Conference Article
  • Citations4

Development and evaluation of data-driven respiratory gating methods with simulated list-mode PET data

  • Oct 01, 2015
  • Jizhe Wang +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.