• Home
  • Search
  • Cascaded Fabry-Perot interferometer with thin film based on Vernier effect
  • Cite Icon8
  • https://doi.org/10.1038/s41598-025-90749-yCopy DOI Icon

Cascaded Fabry-Perot interferometer with thin film based on Vernier effect

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The Vernier effect is often utilized to boost the sensing ability of optical fiber sensors. In this paper, theoretical model of cascaded Fabry-Perot interferometer (FPI) with thin film based on Vernier effect is established. The sensitivities of the envelope spectra, thin film cavity and mixed cavity of air-thin film are analyzed qualitatively. According to the theoretical analysis, although sensitivity from mixed cavity of air-thin film is amplified, the value is equal to the sensitivity of sing thin film cavity. Experimental verification is carried out by an example of thin film named polydimethylsiloxane (PDMS) polymer. Herein, a new FPI constructed by air cavity from a hollow-core fiber, PDMS cavity, and air-PDMS mixed cavity is proposed and demonstrated. In order to facilitate the generation of the Vernier effect, the length of the PDMS cavity is intentionally designed shorter than the air cavity, making the free spectral range of the air-PDMS cavity and air cavity is approximately equal. The temperature change makes the refractive index and thermal expansion of PDMS change, while gas pressure change results in elastic deformation of PDMS. The Vernier envelope wavelength shifts with the temperature and gas pressure change. The proposed FPI features high temperature and gas pressure sensitivities of 3.07 nm/℃, and 23.07 nm/MPa, and a high magnification factor of 17 when the lengths of HCF and PDMS are 82.5 and 3.7 μm, respectively. The experimental results show that the temperature and pressure sensitivities of the cascaded FPI’s envelope spectra are equal to the sensitivity of a single thin film microcavity, and the theoretical calculation is in good agreement with the experimental verification. The theoretical model is also applicable to thin film prepared by other polymer materials. Additionally, the proposed FPI has good stability, reversibility, and repeatability, which is a good choice in the field of optical fiber sensing.

Loading PDF

Similar Papers
  • Research Article
  • Citations40

Cascaded Mach–Zehnder Interferometers With Vernier Effect for Gas Pressure Sensing

  • Apr 15, 2019
  • IEEE Photonics Technology Letters
  • Yujia Zhao +5
  • PDF
  • Research Article
  • Citations3

High sensitivity fiber optic temperature sensor composed of two parallel FPI and enhanced harmonic Vernier effect

  • Apr 28, 2025
  • Scientific Reports
  • Huiling Huang +6
  • Research Article
  • Citations92

Ultrasensitive Temperature Sensor With Cascaded Fiber Optic Fabry–Perot Interferometers Based on Vernier Effect

  • Oct 01, 2018
  • IEEE Photonics Journal
  • Jin Zhang +7
  • Research Article
  • Citations8

High-Sensitive Temperature Sensor With Cascaded Fabry–Perot Interferometers Based on Enhanced Vernier Effect

  • Jan 01, 2025
  • IEEE Sensors Journal
  • Yubo Liu +10
  • Supplementary Content
  • Citations2

High sensitivity optical fiber temperature sensor based on Fabry-Perot interferometer and enhanced vernier effect

  • May 06, 2025
  • Sensor Review
  • Chenyuan Zuo +4
  • Research Article
  • Citations33

Fiber Optic Temperature Sensor With Online Controllable Sensitivity Based on Vernier Effect

  • Oct 01, 2021
  • IEEE Sensors Journal
  • Maolin Dai +9
  • Research Article
  • Citations129

Highly Sensitive Airflow Sensor Based on Fabry–Perot Interferometer and Vernier Effect

  • Oct 12, 2016
  • Journal of Lightwave Technology
  • Yong Zhao +3
  • Research Article
  • Citations14

High-temperature-sensitive and spectrum-contrast-enhanced sensor using a bullet-shaped fiber cavity filled with PDMS.

  • Mar 28, 2022
  • Optics Express
  • Jinjin Liang +7
  • Research Article
  • Citations50

High-Sensitivity Fabry–Perot Interferometer High-Temperature Fiber Sensor Based on Vernier Effect

  • May 15, 2020
  • IEEE Sensors Journal
  • Xueqin Lei +1
  • Conference Article
  • Citations5

High-Sensitive All-Fiber Fabry-Perot Interferometer Gas Refractive Index Sensor Based on Lateral offset Splicing and Vernier Effect

  • Aug 01, 2019
  • Yuxin Zhao +5
  • Research Article
  • Citations67

High-sensitivity Fabry-Perot interferometer temperature sensor probe based on liquid crystal and the Vernier effect.

  • Oct 29, 2018
  • Optics Letters
  • Feiru Wang +6
  • Research Article
  • Citations50

Cascaded Fiber Mach–Zehnder Interferometers for Sensitivity-Enhanced Gas Pressure Measurement

  • Apr 01, 2019
  • IEEE Sensors Journal
  • Hongfeng Lin +3
  • Conference Article
  • Citations2

Enhanced temperature sensing with Vernier effect on fiber probe based on multimode Fabry-Perot interferometer

  • Oct 03, 2019
  • André D Gomes +7
  • Research Article
  • Citations30

High sensitivity gas pressure sensor based on two parallel-connected Fabry–Perot interferometers and Vernier effect

  • Oct 13, 2021
  • Measurement Science and Technology
  • Xiaoshan Guo +3
  • Research Article
  • Citations2

Ultrasensitive optical electric field sensor with temperature compensation for point-wise and quasi-distributed sensing.

  • Oct 22, 2024
  • Optics letters
  • Yongguang Wang +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.