• Cite Icon17
  • https://doi.org/10.1177/153303460400300502Copy DOI Icon

Cassette-based digital mammography.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Over the past several years, digital mammography systems have been installed clinically across North America in small but growing numbers. A photostimulable phosphor-based full-field digital mammography image was evaluated in this investigation. Commonly known as computed radiography (CR), its use closely mimics the screen-film mammography paradigm. System performance using modulation transfer function (MTF) and detective quantum efficiency (DQE) metrics show MTF(2.5 mm(-1)) = 0.5, DQE(2.5 mm(-1)) = 0.3, and MTF(5.0 mm(-1)) = 0.2, DQE(5.0 mm(-1)) = 0.05, for a 26 kVp beam, 0.03 mm molybdenum tube filtration, 4.5 cm tissue attenuation, and 15 mR incident exposure to the detector. Slightly higher DQE values were measured at 32 kVp with 0.025 mm rhodium tube filtration. CR mammography advantages include the ability to use existing mammography machines, where multiple rooms can be converted to "digital" operation, which allows overall cost savings compared to integrated digital mammography systems. Chief disadvantages include the labor-intensive handling of the cassettes prior to and after the imaging exam, lack of a direct interface to the x-ray system for recording technique parameters, and relatively slow processing time. Clinical experience in an IRB-approved research trial has suggested that digital mammography with photostimulable storage phosphors and a dedicated CR reader is a viable alternative to conventional screen-film mammography.

Similar Papers
  • Research Article
  • Citations61

Image quality assessment in digital mammography: part I. Technical characterization of the systems

  • Jun 23, 2011
  • Physics in Medicine & Biology
  • N W Marshall +4
  • Research Article
  • Citations5

Evaluation of an edge method for computed radiography and an electronic portal imaging device in radiotherapy: Image quality measurements

  • Dec 01, 2014
  • Journal of the Korean Physical Society
  • Soon-Yong Son +9
  • Research Article
  • Citations20

Physical evaluation of a needle photostimulable phosphor based CR mammography system

  • Jan 23, 2012
  • Medical Physics
  • Nicholas W Marshall +2
  • Abstract

Getting to grips with quantitative image quality measurements for QA of digital mammography (DM) systems

  • Jul 01, 2016
  • Physica Medica
  • James Mccullagh +3
  • Research Article
  • Citations16

Mammographic findings of women recalled for diagnostic work-up in digital versus screen-film mammography in a population-based screening program

  • Jun 01, 2010
  • Acta Radiologica
  • Seppo Lipasti +2
  • Research Article
  • Citations3

Performance evaluation of six digital mammography systems

  • Feb 23, 2024
  • Radiation Physics and Chemistry
  • Alessandra Maia Marques Martinez Perez +4
  • Research Article
  • Citations33

Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems

  • Sep 03, 2007
  • Physics in Medicine & Biology
  • N W Marshall
  • Conference Article
  • Citations10

Reflective and transmissive CR ScanHead technology on needle image plates

  • Apr 20, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jorg Frankenberger +4
  • Book Chapter
  • Citations8

Computed Radiography: Physics and Technology

  • Jan 01, 2019
  • Euclid Seeram
  • Conference Article
  • Citations19

<title>Image quality of a prototype direct conversion detector for digital mammography</title>

  • May 28, 1999
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • James G Mainprize +4
  • Conference Article
  • Citations9

<title>Practical method for detected quantum efficiency (DQE) assessment of digital mammography systems in the radiological environment</title>

  • May 02, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Frank Rogge +5
  • Research Article
  • Citations56

Characterization of noise sources for two generations of computed radiography systems using powder and crystalline photostimulable phosphors

  • Jul 27, 2007
  • Medical Physics
  • Alistair Mackenzie +1
  • Book Chapter

5 - Full-field Digital Mammography versus Film-screen Mammography

  • Jan 01, 2008
  • Cancer Imaging
  • Arne Fischmann
  • Conference Article
  • Citations3

Performance characterization of computed radiography based mammography systems

  • Mar 04, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Abhinav Singh +2
  • Research Article

PSF and MTF from a bar pattern in digital mammography

  • Jun 20, 2024
  • Biomedical Physics & Engineering Express
  • F R Lozano +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.