Abstract

In this paper we present lightning statistics for more than three million cloud‐to‐ground (CG) flashes located during the 10‐year operation period 1992–2001 of the Austrian lightning location system (LLS) called ALDIS (Austrian Lightning Detection and Information System). Like a majority of other LLS operated worldwide, ALDIS underwent configuration changes and continuous performance improvement. Since these changes can alter the lightning statistics, we also relate the variation of the individual lightning parameters during the period of operation to changes in ALDIS configuration and performance. This analysis should be useful to other network operators and data users. Flash densities in Austria are normally between 0.5 and 4 flashes km −2 yr −1 depending on terrain. Flashes are classified as negative, positive, or bipolar. Seventeen percent of the flashes were classified as positive, and 2.3% of the total number of flashes were bipolar. Fifty percent of the positive multiple‐stroke flashes were bipolar flashes with positive first stroke; this influences the positive flash multiplicity and interstroke interval statistics. Compared to many other networks, the ALDIS network reports much lower median negative peak currents. For 2001, the median first‐stroke peak current for negative flashes was 10 kA. Estimated multiplicity of negative flashes for the 10‐year period is affected by the algorithm that groups strokes into flashes, as well as the improved DE of the network as a result of the integration of ALDIS into the European LLS (EUCLID). This performance improvement also resulted in a higher number of single‐stroke flashes. Interstroke interval and median first‐stroke peak current show a clear correlation with multiplicity for negative flashes, irrespective of detection efficiency. Negative flashes with higher multiplicity show smaller average interstroke intervals and larger first stroke median peak currents. No correlation between interstroke interval and stroke order was found. On average, regions with higher flash density show slightly higher flash multiplicity.

Similar Papers
  • Research Article
  • Citations132

The North American Lightning Detection Network (NALDN)—Analysis of Flash Data: 2001–09

  • May 01, 2011
  • Monthly Weather Review
  • Richard E Orville +3
  • Research Article
  • Citations77

Characteristics of lightning related to wildfire ignitions in Catalonia

  • Jul 21, 2012
  • Atmospheric Research
  • Nicolau Pineda +2
  • Research Article
  • Citations314

Cloud-to-Ground Lightning in the United States: NLDN Results in the First Decade, 1989–98

  • May 01, 2001
  • Monthly Weather Review
  • Richard E Orville +1
  • Research Article
  • Citations29

A decade of high‐latitude lightning location: Effects of the evolving location network in Finland

  • Nov 11, 2010
  • Journal of Geophysical Research: Atmospheres
  • Antti Mäkelä +2
  • Research Article
  • Citations26

Ground truth data of atmospheric discharges in correlation with LLS detections

  • Dec 03, 2019
  • Electric Power Systems Research
  • Lukas Schwalt +2
  • Conference Article

Tropical lightning stroke data collected and analyzed by computer based lightning detecting station

  • Aug 13, 2001
  • S.A Fedoseev +1
  • Research Article
  • Citations66

Pre- and Postupgrade Distributions of NLDN Reported Cloud-to-Ground Lightning Characteristics in the Contiguous United States

  • Sep 01, 2010
  • Monthly Weather Review
  • Scott D Rudlosky +1
  • PDF
  • Research Article
  • Citations117

High‐speed video observations of positive lightning flashes to ground

  • Dec 16, 2010
  • Journal of Geophysical Research: Atmospheres
  • Marcelo M F Saba +7
  • Research Article
  • Citations34

Monthly distribution of cloud‐to‐ground lightning flashes as observed by lightning location systems

  • May 01, 2006
  • Geophysical Research Letters
  • O Pinto +4
  • Research Article
  • Citations35

Seasonal, Regional, and Storm-Scale Variability of Cloud-to-Ground Lightning Characteristics in Florida

  • Jun 01, 2011
  • Monthly Weather Review
  • Scott D Rudlosky +1
  • Book Chapter

Lightning location systems

  • Dec 31, 2022
  • Gerhard Diendorfer +1
  • Conference Article
  • Citations4

Detection of upward lightning by lightning location systems

  • Oct 01, 2014
  • Amanda R De Paiva +6
  • Conference Article
  • Citations6

An overview of Pekan Lightning Detection System (PLDS)

  • Dec 01, 2012
  • W.I Ibrahim +1
  • Research Article
  • Citations13

Time-intervals between negative lightning strokes and the creation of new ground terminations

  • Mar 31, 2012
  • Atmospheric Research
  • Marco Antonio Da Silva Ferro +2
  • Research Article
  • Citations15

Assessment of the Lightning Performance of overhead distribution lines based on Lightning Location Systems data

  • Apr 29, 2022
  • International Journal of Electrical Power & Energy Systems
  • Martino Nicora +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.