• Home
  • Search
  • Coding Huygens' metasurface for enhanced quality holographic imaging.
  • Cite Icon61
  • https://doi.org/10.1364/oe.27.007108Copy DOI Icon

Coding Huygens' metasurface for enhanced quality holographic imaging.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

In this paper, coding Huygens' metasurface (CHM) is proposed for holographic imaging with enhanced quality. A weighted holographic algorithm is used to calculate the phase distribution at the interface and to design the CHM. Experimental demonstration performed in the microwave region validates holographic imaging with the ability to modulate energy distribution among focal points and improve image quality. By judiciously engineering both electric and magnetic dipolar resonators, the proposed digital Huygens' meta-atom is able to provide a full transmission-phase covering the whole range of 2π together with a near-unity transmission efficiency. The proof-of-concept experiments show that holographic imaging quality can be indeed improved by using digital meta-atoms with several bits. Furthermore, the modulation of intensity distribution among focal points is experimentally realized by using the 3-bits CHM. The proposed CHM hologram shows great potential in a variety of application fields, such as programmable high-resolution imaging lenses, microscopy, data storage, information processing, and computer-generated holograms.

Similar Papers
  • PDF
  • Research Article

Pediatric 3D MRCP imaging: strategies for enhancing exam quality

  • Jun 27, 2025
  • Abdominal Radiology (New York)
  • Mohammad Jalloul +12
  • Research Article
  • Citations2

Improving Image Quality by Deconvolution Recovery Filter in Ultrasound Imaging.

  • Dec 16, 2022
  • Ultrasonic Imaging
  • Jingwen Pan +5
  • Research Article
  • Citations7

Image quality in conventional lumbar spine radiography: Evaluation using the post-processing tool Diamond View ®

  • Mar 12, 2008
  • European Journal of Radiology
  • Tilo Niemann +3
  • Research Article

Improving image quality by optimizing beam width and helical pitch in CT.

  • Mar 15, 2022
  • Journal of X-Ray Science and Technology
  • Pil-Hyun Jeon +1
  • Research Article
  • Citations10

Visual perception of noise in a simulated holographic display—A user study

  • Nov 14, 2022
  • Displays
  • Andreas Georgiou +4
  • Research Article
  • Citations1

Quality assessment of binary object images reconstructed by computer-generated holograms

  • Jun 01, 2020
  • Scientific and Technical Journal of Information Technologies, Mechanics and Optics
  • S.N Koreshev +3
  • Conference Article
  • Citations5

Perceptual difference paradigm for analyzing image quality of fast MRI techniques

  • May 21, 2003
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • David L Wilson +3
  • Conference Article

Optical analysis of freeform spectacle lens based on eye model

  • Nov 01, 2019
  • Jiang Weiwei +2
  • Research Article
  • Citations5

Generative Diffusion Model for Seismic Imaging Improvement of Sparsely Acquired Data and Uncertainty Quantification

  • Jan 01, 2024
  • IEEE Transactions on Geoscience and Remote Sensing
  • Xingchen Shi +3
  • Research Article

Effect of the cone-beam CT acquisition trajectory on image quality in spine surgery: experimental cadaver study

  • Aug 21, 2024
  • The Spine Journal
  • Maxim Fikuart +5
  • Research Article
  • Citations23

MR image quality in local staging of prostate cancer: Role of PI-QUAL in the detection of extraprostatic extension

  • Jul 11, 2023
  • European Journal of Radiology
  • Andrea Ponsiglione +9
  • Research Article
  • Citations3

Improving coherent field imaging quality by suppressing the influence of transmitting aperture spacing error

  • Jan 01, 2015
  • Acta Physica Sinica
  • Cheng Zhi-Yuan +5
  • Research Article

MO‐D‐213A‐01: ACR Accreditation

  • Jun 01, 2009
  • Medical Physics
  • Carolyn R Macfarlane
  • Supplementary Content

Dataset for High-performance geometric phase elements in silica glass

  • May 12, 2017
  • ePrints Soton (University of Southampton)
  • Rokas Drevinskas +1
  • Research Article
  • Citations12

Utilization of 3-T fetal magnetic resonance imaging in clinical practice: a single-institution experience.

  • May 19, 2021
  • Pediatric Radiology
  • Usha D Nagaraj +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.