Abstract

This paper deals with structural damage detection using measured frequency response functions (FRF) as input data to artificial neural networks (ANN). A major obstacle, the impracticality of using full-size FRF data with ANNs, was circumvented by applying a data-reduction technique based on principal component analysis (PCA). The compressed FRFs, represented by their projection onto the most significant principal components, were used as the ANN input variables instead of the raw FRF data. The output is a prediction of the actual state of the specimen, i.e. healthy or damaged. A further advantage of this particular approach is its ability to deal with relatively high measurement noise, which is a common occurrence when dealing with industrial structures. The methodology was applied to detect three different states of a space antenna: reference, slight mass damage and slight stiffness damage. About 600 FRF measurements, each with 1024 spectral points, were included in the analysis. Six 2-hidden layer networks, each with an individually-optimised architecture for a specific FRF reduction level, were used for damage detection. The results showed that it was possible to distinguish between the three states of the antenna with good accuracy, subject to using an adequate number of principal components together with a suitable neural network configuration. It was also found that the quality of the raw FRF data remained a major consideration, though the method was able to filter out some of the measurement noise. The convergence and detection properties of the networks were improved significantly by removing those FRFs associated with measurement errors.

Similar Papers
  • Research Article
  • Citations255

STRUCTURAL DAMAGE DETECTION USING ARTIFICIAL NEURAL NETWORKS AND MEASURED FRF DATA REDUCED VIA PRINCIPAL COMPONENT PROJECTION

  • May 01, 2001
  • Journal of Sound and Vibration
  • C Zang +1
  • Book Chapter
  • Citations1

Seismic damage evaluation of a 38-storey building model using measured FrF data reduced via principal component analysis

  • Jan 01, 2002
  • Advances in Building Technology
  • J.M Ko +2
  • Research Article
  • Citations123

Non-probabilistic method to consider uncertainties in frequency response function for vibration-based damage detection using Artificial Neural Network

  • Nov 06, 2019
  • Journal of Sound and Vibration
  • Khairul H Padil +4
  • Research Article
  • Citations59

Structural Damage Detection in a Truss Bridge Model Using Fuzzy Clustering and Measured FRF Data Reduced by Principal Component Projection

  • Jan 01, 2013
  • Advances in Structural Engineering
  • Ling Yu +2
  • Conference Article
  • Citations11

Parametric study on PCA-based algorithm for structural health monitoring

  • Jan 01, 2010
  • Ling Yu +2
  • Conference Article
  • Citations11

Combined Neural Network and PCA for Complicated Damage Detection of Bridge

  • Jan 01, 2009
  • Yanfei Sun
  • Research Article
  • Citations169

Structural damage detection using measured FRF data

  • Jul 01, 1997
  • Computer Methods in Applied Mechanics and Engineering
  • Z Wang +2
  • Research Article
  • Citations131

Experimental investigation of seismic damage identification using PCA-compressed frequency response functions and neural networks

  • Jun 15, 2005
  • Journal of Sound and Vibration
  • Y.Q Ni +2
  • Conference Article
  • Citations27

An artificial neural network approach to structural damage detection using frequency response functions

  • Apr 21, 1994
  • Clinton Povich +1
  • Research Article
  • Citations157

Frequency response function based damage identification using principal component analysis and pattern recognition technique

  • Mar 09, 2014
  • Engineering Structures
  • Rupika P Bandara +2
  • Research Article
  • Citations2

Damage detection in plate structures using frequency response function and 2D-PCA

  • Oct 01, 2017
  • Smart Structures and Systems
  • Faramarz Khoshnoudian +1
  • Research Article
  • Citations141

Structural damage detection method using frequency response functions

  • Feb 19, 2014
  • Structural Health Monitoring
  • Rupika P Bandara +2
  • Research Article
  • Citations115

Damage identification in civil engineering structures utilizing PCA-compressed residual frequency response functions and neural network ensembles

  • Mar 01, 2011
  • Structural Control and Health Monitoring
  • Jianchun Li +3
  • Research Article
  • Citations21

A New Damage Index Using FRF Data, 2D-PCA Method and Pattern Recognition Techniques

  • Oct 01, 2017
  • International Journal of Structural Stability and Dynamics
  • F Khoshnoudian +1
  • Research Article
  • Citations3

Uncertainties Consideration in Empirical Frequency Response Function Data for Damage Identification Based On Artificial Neural Network

  • Jun 10, 2021
  • International Journal of Integrated Engineering
  • Khairul H Padil +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.