• Home
  • Search
  • Combining Electrical and Magnetic Fields for Source Analysis: A(n) Attractive or Repelling Thought
  • https://doi.org/10.1177/1535759719868692Copy DOI Icon

Combining Electrical and Magnetic Fields for Source Analysis: A(n) Attractive or Repelling Thought

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Electromagnetic Source Imaging in Presurgical Workup of Patients With Epilepsy: A Prospective Study.Duez L, Tankisi H, Hansen PO, et al. Neurology. 2019;92(6):e576-e586. doi:10.1212/WNL.0000000000006877. Epub 2019 Jan 4. PMID: 30610090Objective:To determine the diagnostic accuracy and clinical utility of electromagnetic source imaging (EMSI) in presurgical evaluation of patients with epilepsy.Methods:We prospectively recorded magnetoencephalography (MEG) simultaneously with electroencephalogram (EEG) and performed EMSI, comprising electric source imaging, magnetic source imaging, and analysis of combined MEG-EEG data sets, using 2 different software packages. As reference standard for irritative zone (IZ) and seizure onset zone (SOZ), we used intracranial recordings and for localization accuracy outcome 1 year after operation.Results:We included 141 consecutive patients. Electromagnetic source imaging showed localized epileptiform discharges in 94 (67%) patients. Most (72%) of the epileptiform discharge clusters were identified by both modalities, 15% only by EEG, and 14% only by MEG. Agreement was substantial between inverse solutions and moderate between software packages. Electromagnetic source imaging provided new information that changed the management plan in 34% of the patients, and these changes were useful in 80%. Depending on the method, EMSI had a concordance of 53% to 89% with IZ and 35% to 73% with SOZ. Localization accuracy of EMSI was between 44% and 57% which was not significantly different from magnetic resonance imaging (49%-76%) and PET (54%-85%). Combined EMSI achieved significantly higher odds ratio compared to electric source imaging and magnetic source imaging.Conclusion:Electromagnetic source imaging has accuracy similar to established imaging methods and provides clinically useful, new information in 34% of the patients.Classification of evidence:This study provides class IV evidence that EMSI had a concordance of 53% to 89% and 35% to 73% (depending on analysis) for the localization of epileptic focus when compared to intracranial recordings (IZ and SOZ), respectively.

Similar Papers
  • Research Article

Localization of interictal spikes and high frequency oscillations (HFO) using magnetoencephalography (MEG)

  • Jan 01, 2016
  • Frontiers in Human Neuroscience
  • Poghosyan Vahe
  • Research Article
  • Citations8

Preoperative localization of seizure onset zones by magnetic source imaging, EEG-correlated functional MRI, and their combination.

  • May 15, 2020
  • Journal of neurosurgery
  • Assaf Berger +10
  • Research Article
  • Citations81

Assessing the localization accuracy and clinical utility of electric and magnetic source imaging in children with epilepsy

  • Jan 31, 2019
  • Clinical Neurophysiology
  • Eleonora Tamilia +9
  • Research Article

Sleep enhances gamma oscillations in the seizure onset zone and broadband activity in the irritative zone of focal cortical dysplasia

  • Jan 20, 2026
  • Epilepsia Open
  • Mohammad F Khazali +14
  • Research Article
  • Citations112

Source localization of the seizure onset zone from ictal EEG/MEG data.

  • Apr 05, 2016
  • Human Brain Mapping
  • Giovanni Pellegrino +7
  • Research Article
  • Citations193

Magnetoencephalographic localization in pediatric epilepsy surgery: comparison with invasive intracranial electroencephalography.

  • Oct 01, 1999
  • Annals of Neurology
  • Berge A Minassian +5
  • Supplementary Content
  • Citations9

Magnetoencephalography in pediatric epilepsy

  • Oct 01, 2013
  • Korean Journal of Pediatrics
  • Hunmin Kim +2
  • Research Article
  • Citations133

Epileptic networks in focal cortical dysplasia revealed using electroencephalography-functional magnetic resonance imaging.

  • Nov 01, 2011
  • Annals of neurology
  • Rachel Thornton +14
  • Book Chapter

28 - Perfusion Imaging and Magnetoencephalography

  • Sep 17, 2019
  • Caffey's Pediatric Diagnostic Imaging
  • Arastoo Vossough
  • Research Article
  • Citations184

Localization of language-specific cortex by using magnetic source imaging and electrical stimulation mapping.

  • Nov 01, 1999
  • Journal of Neurosurgery
  • Panagiotis G Simos +6
  • Research Article
  • Citations29

Localizing the Epileptogenic Zone with Novel Biomarkers

  • Aug 20, 2021
  • Seminars in Pediatric Neurology
  • Christos Papadelis +1
  • PDF
  • Supplementary Content
  • Citations101

The Role of Functional Neuroimaging in Pre-Surgical Epilepsy Evaluation

  • Mar 24, 2014
  • Frontiers in Neurology
  • Francesca Pittau +5
  • Research Article
  • Citations3

Evidence From Meta-Analysis Supports Ictal Magnetoencephalographic Source Imaging as an Accurate Method in Presurgery Evaluation of Patients With Drug-Resistant Epilepsy.

  • May 21, 2020
  • Clinical EEG and Neuroscience
  • Malthe Brændholt +1
  • Abstract

ID 168 – Source localization of ictal epileptic activity based on high density scalp EEG data

  • Feb 10, 2016
  • Clinical Neurophysiology
  • P Nemtsas +6
  • Research Article

Clinical Neurophysiology: EEG–Video Monitoring

  • Oct 01, 2005
  • Epilepsia
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.