• Home
  • Search
  • Comparation between Keeler and ORA IOP measurements
  • https://doi.org/10.1111/j.1755-3768.2012.f005.xCopy DOI Icon

Comparation between Keeler and ORA IOP measurements

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Abstract Purpose To evaluate the relationship between intraocular pressure (IOP) measurements obtained with Pulsair EasyEye (PEE) and Ocular Response Analyser (ORA) in healthy subjects.Methods Sixty‐five eyes from 65 healthy subjects were prospective and consecutively evaluated. All of them underwent a full optometric examination, including central corneal thickness (CCT), and IOP measured with both PEE and ORA devices. Differences between IOP measurements between both tonometers were analyzed.Results Statistically differences were found between IOP measurements of PEE (IOPk) and ORA Goldmann‐corrected IOP (IOPg; p=0.001). IOPk and ORA corneal resistance‐corrected IOP (IOPcc) were also statistically different (p=0.025). However, no differences between IOPg and IOPcc were found (p=0.952). Mean differences between IOPg‐IOPk, IOPcc‐IOPk and IOPg‐IOPcc (±SD) were 0.71±1.66, 0.70±2.46 and 0.01±1.54 mmHg respectively. Pearson correlation coefficients showed that IOPk, IOPg, IOPcc were significantly correlated (p<0.001): r=0.816 for IOPk‐IOPg, r=0.826 for IOPcc‐IOPg and r=0.587 IOPcc‐IOPk.Conclusion There are statistically differences between mean IOP values measured with PEE and ORA. ORA tonometer provides higher IOP values than PEE in most of the cases. IOPk, IOPcc and IOPg have, at least, moderate positive linear correlations between them.

Similar Papers
  • Research Article

Ocular Response Analyzer versus Goldmann Applanation Tonometer for Measurement of Intra-Ocular Pressure

  • Oct 01, 2021
  • QJM: An International Journal of Medicine
  • Rim Raafat Fayez +3
  • Research Article
  • Citations15

Comparison between Corvis and other tonometers in healthy eyes.

  • Nov 22, 2014
  • Contact Lens and Anterior Eye
  • Michele Lanza +5
  • PDF
  • Research Article
  • Citations17

Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST

  • Oct 16, 2019
  • Journal of Ophthalmology
  • Lisa Ramm +5
  • Research Article
  • Citations441

Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer

  • Dec 01, 2006
  • Investigative Opthalmology & Visual Science
  • Aachal Kotecha +4
  • Research Article
  • Citations34

Noninvasive Determination of Intraocular Pressure (IOP) in Nonsedated Mice of 5 Different Inbred Strains

  • Jan 01, 2007
  • Journal of Glaucoma
  • Nicholas Nissirios +4
  • Research Article
  • Citations33

The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry

  • Aug 29, 2009
  • Graefe's Archive for Clinical and Experimental Ophthalmology
  • Teresio Avitabile +5
  • PDF
  • Research Article
  • Citations6

Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA

  • Feb 16, 2022
  • BMC Ophthalmology
  • María Iglesias +6
  • Research Article
  • Citations1

Comparison of IOP obtained in different kind of eyes with contact and no contact tonometers

  • Sep 01, 2022
  • Oman Journal of Ophthalmology
  • Sandro Sbordone +6
  • Research Article
  • Citations35

Der Einfluss von kornealer Hysterese und kornealem Resistenzfaktor auf die Messung des intraokularen Drucks

  • Jun 01, 2007
  • Der Ophthalmologe
  • A Hager +4
  • Research Article
  • Citations169

Influence of Corneal Structure, Corneal Responsiveness, and Other Ocular Parameters on Tonometric Measurement of Intraocular Pressure

  • Oct 01, 2007
  • Journal of Glaucoma
  • Aimee Teo Broman +3
  • Research Article
  • Citations25

Modifications in Corneal Biomechanics and Intraocular Pressure After Deep Sclerectomy

  • Apr 01, 2010
  • Journal of Glaucoma
  • Vasiliki Iordanidou +5
  • Research Article
  • Citations1

The relationship between corneal biomechanical properties and intraocular pressure

  • Sep 01, 2011
  • Acta Ophthalmologica
  • K Ogbuehi +1
  • Research Article
  • Citations44

The effect of corneal thickness and corneal curvature on pneumatonometer measurements

  • Jan 01, 2002
  • Current Eye Research
  • Andrew J Morgan +3
  • Research Article
  • Citations31

Effect of Central Corneal Thickness and Radius of the Corneal Curvature on Intraocular Pressure Measured With the Tono-Pen and Noncontact Tonometer in Healthy Schoolchildren

  • Jan 01, 2007
  • Journal of Pediatric Ophthalmology & Strabismus
  • Nilgun Yildirim +3
  • Research Article
  • Citations4

Improved prediction of fellow-eye response in one-eye trials using multiple intraocular pressure measurements

  • Sep 01, 2011
  • Japanese Journal of Ophthalmology
  • Yuka Wakabayashi +2
Cactus Communications logo