Application of automatic tube current modulation combined with iterative reconstruction algorithm in low- dose CT pulmonary angiography
- Nov 25, 2016
- Zhonghua fangshe yixue yu fanghu zazhi
- Chao He + 6 more +6
Objective To explore the application value of automatic tube current modulation combined with iterative reconstruction algorithm (idose4) in low-dose computed tomography pulmonary angiography (CTPA). Methods A total of 80 patients with CTPA collected continuously were randomly divided into control group (n=40, 80 kV, 180 mAs) and experimental group (n=40, 80 kV, automatic tube current modulation). The data sets of control group were reconstructed with filtered-back-projection algorithm (group A), and the data sets of experimental group were reconstructed with filtered-back-projection algorithm (group B) and iterative reconstruction algorithm (group C). Subjective score, mean CT values of pulmonary artery, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were recorded. Effective dose (E) was compared. Results The E of experimental group was decreased by 36.8% compared to control group (t=-3.998, P 0.05). There was statistically significant difference for the SNR, CNR and image noise of 3 groups (F=10.411, 7.630, 13.021, P 0.05). Conclusions Using automatic tube current modulation combined with iterative reconstruction algorithm in low-dose CTPA could meet the requirements of image quality, and reduce the radiation dose to a certain extent. Key words: Computed tomography pulmonary angiography; Radiation dose; Iterative reconstruction; Automatic tube current modulation